1-4 Specifications
1-11
1
2
3
4
5
6
7
8
9
10
11
付
Ou
tlin
e
s
CG
Model
Item
SHA40Y
50
80
100
120
160
Combined Servopack
SGD7S-180A20A
□□□
F81
Max. torque
*1
Nm
523
675
738
802
841
kgf
・
m
53.4
68.9
75.3
81.8
85.8
Allowable continuous
torque
*2*3
Nm
157
260
327
382
382
kgf
・
m
16.0
26.5
33.3
39.0
39.0
Max. rotational speed
*2
rpm
80
50
40
33.3
25
Torque constant
*2
Nm/A
25
40
50
60
80
kgf
・
m/A
2.5
4.1
5.1
6.1
8.2
Max. current
*1
A
27.2
22.0
19.6
18.0
14.7
Allowable continuous
current
*1*2
A
9.0
9.0
9.0
8.8
7.2
MEF constant
V/(rpm)
2.8
4.5
5.6
6.7
9.0
Phase resistance
(
20
℃
)
Ω
0.19
Phase inductance
mH
1.2
Inertia
moment
(without
brake)
GD
2
/4
kg
・
m
2
4.8
12
19
27
49
J
kgf
・
cm
・
s
2
49
124
194
280
497
Inertia
moment
(with
brake)
GD
2
/4
kg
・
m
2
5.8
15
23
33
59
J
kgf
・
cm
・
s
2
59
150
235
338
601
Reduction ratio
-
1:50
1:80
1:100
1:120
1:160
Permissible moment
load
Nm
849
kgf
・
m
86.6
Moment stiffness
Nm/rad
179
×
10
4
kgf
・
m/arc
min
53.2
One-way positional
accuracy
Sec
40
30
30
30
30
Repeatability
Sec
±
4
Reverse positional
accuracy
Sec
50
20
20
20
20
Encoder type
-
Magnetic absolute encoder
Single motor revolution
Encoder resolution
Pulse/rev
2
17
(
131,072
)
Motor multi revolution
counte
Count
2
16
(
65,536
)
Output shaft resolution
Pulse/rev
6,553,600
10,485,760
13,107,200
15,728,640
20,971,520
Mass
(without brake)
kg
13.0
Mass (with brake)
kg
13.8
Environmental conditions
Operating temperature: 0 to 40
℃
/Storage temperature: -20 to 60
℃
Operating humidity/storage humidity: 20 to 80%RH (no condensation)
Resistance to vibration: 25 m/s
2
(frequency: 10 to 400Hz)/Shock resistance:
300 m/s
2 *4
No dust, no metal powder, no corrosive gas, no inflammable gas, no oil mist
To be used indoors, no direct sunlight
Altitude: less than 1,000 m above sea level
Motor insulation
Insulation resistance: 100MΩ or more (by DC500V insulation test
er)
Dielectric strength: AC1,500V/1 min
Insulation class: A
Mounting direction
Can be installed in any direction.
Protection structure
Totally enclosed self-cooled type (IP54)
The table shows typical output values of actuators.
*1: Indicates typical cha
racteristics when combined with Σ
-7 (driven using an ideal sine wave).
*2: Value after temperature rise and saturation when the 500 x 500 x 25 [mm] aluminum radiation plate is installed.
*3: Value of phase induced voltage constant multiplied by 3.
*4: For testing conditions, refer to [1-12 Shock resistance] (P1-36) and [1-13 Resistance to vibration] (P1-37).
Содержание SHA - Y series
Страница 1: ...AC Servo Actuator S H A Y s e r i e s m a n u a l ISO14001 ISO9001...
Страница 61: ...1 15 Cable specifications 1 49 1 2 3 4 5 6 7 8 9 10 11 Outlines...
Страница 77: ...2 4 Examining operating status 2 15 1 2 3 4 5 6 7 8 9 10 11 Selection guidelines...
Страница 86: ...Chapter 4 Options This chapter explains the options available for the SHA Y series actuator 4 1 Options 4 1...
Страница 92: ...Chapter 5 Appendix A 1 Unit conversion 5 1 A 2 Calculating inertia moment 5 3...
Страница 98: ...Calculating moment of inertia 5 6 1 2 3 4 Apx 6 7 8 9 10 11 Appendix...
Страница 99: ......
Страница 101: ......