1-4 Specifications
1-7
1
2
3
4
5
6
7
8
9
10
11
付
Ou
tlin
e
s
SG
Model
Item
SHA40Y
51
81
101
121
161
Combined Servopack
SGD7S-180A20A
□□□
F81
Max. torque
*2
Nm
523
675
738
802
841
kgf
・
m
53.4
68.9
75.3
81.8
85.8
Allowable continuous
torque
*2*3
Nm
160
263
330
382
382
kgf
・
m
16.3
26.8
33.7
39
39
Max. rotational speed
*2
rpm
78.4
49.4
39.6
33.1
24.8
Torque constant
*2
Nm/A
25
41
51
61
81
kgf
・
m/A
2.6
4.1
5.2
6.2
8.2
Max. current
*2
A
26.7
21.8
19.4
17.9
14.6
Allowable continuous
current
*2*3
A
9.0
9.0
9.0
8.8
7.2
MEF constant
*4
V/(rpm)
2.9
4.6
5.7
6.8
9.1
Phase resistance
(
20
℃
)
Ω
0.19
Phase inductance
mH
1.2
Inertia
moment
(without
brake)
GD
2
/4
kg
・
m
2
5.0
13
20
28
50
J
kgf
・
cm
・
s
2
51
130
202
290
513
Inertia
moment
(with
brake)
GD
2
/4
kg
・
m
2
6.1
15
24
34
61
J
kgf
・
cm
・
s
2
62
157
244
350
619
Reduction ratio
-
1:51
1:81
1:101
1:121
1:161
Permissible
moment load
Nm
849
kgf
・
m
86.6
Moment stiffness
Nm/rad
179
×
10
4
kgf
・
m/arc
53.2
One-way positional
accuracy
Sec.
50
40
40
40
40
Encoder type
-
Magnetic absolute encoder
Single motor revolution
Encoder resolution
Pulse/rev
2
17
(
131,072
)
Motor multi revolution
counter
Count
2
16
(
65,536
)
Output shaft resolution
Pulse/rev
6,684,672
10,616,832
13,238,272
15,859,
712
21,102,
592
Mass
(without brake)
kg
9.9
Mass (with brake)
kg
10.7
Environmental conditions
Operating temperature: 0 to 40
℃
/Storage temperature: -20 to 60
℃
Operating humidity/storage humidity: 20 to 80%RH (no condensation)
Resistance to vibration: 25 m/s
2
(frequency: 10 to 400Hz)/Shock
resistance: 300 m/s
2 *4
No dust, no metal powder, no corrosive gas, no inflammable gas, no oil mist
To be used indoors, no direct sunlight
Altitude: less than
1,000 m above sea level
Motor insulation
Insulation resistance: 100MΩ or more (by DC500V insulation tester)
Dielectric strength: AC1,500V/1 min
Insulation class: A
Mounting direction
Can be installed in any direction.
Protection structure
Totally enclosed self-cooled type (IP54)
The table shows typical output values of actuators.
*1:
Indicates typical characteristics when combined with Σ
-7 (driven using an ideal sine wave).
*2: Value after temperature rise and saturation when the 500 x 500 x 25 [mm] aluminum radiation plate is installed.
*3: Value of phase induced voltage constant multiplied by 3.
*4: For testing conditions, refer to [1-12 Shock resistance] (P1-36) and [1-13 Resistance to vibration] (P1-37).
Содержание SHA - Y series
Страница 1: ...AC Servo Actuator S H A Y s e r i e s m a n u a l ISO14001 ISO9001...
Страница 61: ...1 15 Cable specifications 1 49 1 2 3 4 5 6 7 8 9 10 11 Outlines...
Страница 77: ...2 4 Examining operating status 2 15 1 2 3 4 5 6 7 8 9 10 11 Selection guidelines...
Страница 86: ...Chapter 4 Options This chapter explains the options available for the SHA Y series actuator 4 1 Options 4 1...
Страница 92: ...Chapter 5 Appendix A 1 Unit conversion 5 1 A 2 Calculating inertia moment 5 3...
Страница 98: ...Calculating moment of inertia 5 6 1 2 3 4 Apx 6 7 8 9 10 11 Appendix...
Страница 99: ......
Страница 101: ......