1-6 Mechanical accuracy
1-8
Apx
Apx
10
11
1
2
3
4
5
6
7
8
9
10
11
Ou
tlin
es
1-6
Mechanical accuracy
The mechanical accuracies of the output shaft and mounting flange are shown below for FHA-C mini
series actuators.
Mechanical accuracy
Accuracy items
FHA-8C
FHA-11C FHA-14C
1. Output shaft
surface runout
0.010
2. Deflection of
output shaft
0.010
3. Parallelism
between the
output shaft end
mounted surface
0.040
4. Concentricity
between the
output shaft and
fitting part
0.040
Note: All values are T.I.R. (Total Indicator Reading).
The measuring for the values are as follows:
1
Output shaft surface runout
The dial gauge on the fixed part measures the axial
runout (maximum runout width) of the outermost
periphery of output shaft of the output rotary unit per
revolution.
2
Deflection of output shaft
The dial gauge on the fixed part measures the radial
runout (maximum runout width) of output shaft of the
output rotary unit per revolution.
3
Parallelism between the output shaft end mounted surface
The dial gauge on the output rotary unit measures the
axial runout (maximum runout width) of the outermost
periphery of the mounting surface (both on the output
shaft side and opposite side) of the output rotary unit
per revolution.
4
Concentricity between the output shaft and fitting part
The dial gauge on the output rotary unit measures the
radial runout (maximum runout width) of the fitting part
of the output rotary unit per revolution.
A
4
2
A
B
1
3 B
(2)
(1)
(3)
(4)
Unit: mm
Содержание FHA - C mini Series
Страница 30: ...1 14 Cable specifications 1 21 1 2 3 4 5 6 7 8 9 10 11 Apx Outlines...
Страница 54: ...3 5 PL09 Magnetic pole detection level setting Installation 3 7 1 2 3 4 5 6 7 8 9 10 11 Apx Installation...
Страница 55: ...4 Option Options you can purchase as necessary are explained in this chapter 4 1 Extension cable 4 1 Chapter...
Страница 60: ...4 1 Extension cable Option 4 5 1 2 4 4 5 6 7 8 9 10 11 Apx Option...