1-4 Specifications
1-5
1
2
3
4
5
6
7
8
9
10
11
Apx
Ou
tlin
es
Input voltage: 24VDC specification
The specifications for FHA-C mini series actuators with a 24VDC input voltage are as follows.
Model
Item
FHA-8C
30
50
100
Maximum torque
Note 2
N
・
m
1.8
3.3
4.8
kgf
・
m
0.18
0.34
0.49
Allowable continuous torque
Note 2, Note 5
N
・
m
0.75
1.5
2
kgf
・
m
0.08
0.15
0.2
Maximum rotational speed
r/min
193
116
58
Torque constant
N
・
m/A
0.8
1.3
2.7
kgf
・
m/A
0.08
0.13
0.28
Maximum current
Note 2
A
3.0
3.3
2.4
Allowable continuous current
Note 2
A
1.6
1.7
1.3
Input power supply (amplifier)
V
DC24V
MEF constant
Note 6
V/(r/min)
0.10
0.16
0.32
Phase resistance
Ω
(20
℃
)
0.54
Phase inductance
mH
0.22
Inertia moment
(GD
2
/4)
(J)
kg
・
m
2
0.0026
0.0074
0.029
kgf
・
cm
・
s
2
0.0270
0.0750
0.30
Reduction ratio
30
50
100
Permissible moment load
N
・
m
15
kgf
・
m
1.5
Moment stiffness
N
・
m/rad
2 x 10
4
kgf
・
m/rad
0.2 x 10
4
Encoding format
Incremental encoder
Encoder resolution
Note 4
pls/rev
2,000
[
8,000
]
Actuator resolution
Note 4
pls/rev
[
240,000
]
[
400,000
]
[
800,000
]
Uni-directional positional accuracy
Sec. (angle)
150
120
120
Mass
kg
0.40
Protection structure
Totally enclosed self-cooled type
Environmental conditions
Operating temperature: 0 to 40°C /Storage temperature: -20 to
60°C
Operating humidity/storage humidity: 20 to 80% RH (no
condensation)
Resistance to vibration: 24.5 m/s
2
(frequency 10 to 400 Hz)
Shock resistance: 294 m/s
2
No dust, metal powder, corrosive gas, inflammable gas, or oil
mist.
To be used indoors, no direct sunlight.
Altitude: less than 1,000 m above sea level
Motor insulation
Insulation resistance: 100 MΩ or more (by 500VDC insulation
tester)
Dielectric strength: 500VAC/1 min
Insulation class: B
Safety standard compliance
CE marking
Mounting direction
Can be installed in any direction
Note 1: The table above shows the values for the output shaft.
Note 2: The values obtained when combined with an MR-J4W2-0303B-MX940J servo amplifier (driven using an
ideal sine wave).
Note 3: All values shown are typical values.
Note 4: The values in brackets are resolution obtained when combined with an amplifier and multiplied by 4.
Note 5: Value with saturated temperature rise when installed on a 150 × 150 × 6 [mm] aluminum radiation plate.
Note 6: Value with 3× phase induced voltage.
Содержание FHA - C mini Series
Страница 30: ...1 14 Cable specifications 1 21 1 2 3 4 5 6 7 8 9 10 11 Apx Outlines...
Страница 54: ...3 5 PL09 Magnetic pole detection level setting Installation 3 7 1 2 3 4 5 6 7 8 9 10 11 Apx Installation...
Страница 55: ...4 Option Options you can purchase as necessary are explained in this chapter 4 1 Extension cable 4 1 Chapter...
Страница 60: ...4 1 Extension cable Option 4 5 1 2 4 4 5 6 7 8 9 10 11 Apx Option...