background image

 

 

 

 

 

 

 

 

 

 

AC Servo Actuator 

FHA - C mini Series 

Mitsubishi Electric AC servo amplifier 
"MELSERVO-J4" SSCNET

/H communication compatible 

  Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ISO14001 

 

 

ISO9001 

 

Содержание FHA - C mini Series

Страница 1: ...AC Servo Actuator FHA C mini Series Mitsubishi Electric AC servo amplifier MELSERVO J4 SSCNET H communication compatible Manual ISO14001 ISO9001...

Страница 2: ...of the product Read this document carefully and use the product correctly so that the product can be used safely for many years Product specifications are subject to change without notice for improvem...

Страница 3: ...ded to prevent non operation or malfunction of the product or negative effects on its performance or function LIMITATION OF APPLICATIONS The equipment listed in this document may not be used for the a...

Страница 4: ...end that installation be performed under the environment where the relative humidity is 40 to 70 RH CAUTION FOR ACTUATORS IN OPERATIONS Never connect cables directly to a power supply socket Each actu...

Страница 5: ...his product be sure to read the MELSERVO J4 SERIES AC SERVO SAFETY GUIDE which comes together with the servo amplifier CAUTION IN OPERATIONS Before performing operations set and check the parameters B...

Страница 6: ...ction guidelines Selection guidelines for the FHA C mini series actuator are explained in this chapter Chapter 3 Installation This chapter explains the procedure for installing the FHA C mini series a...

Страница 7: ...d specification 1 6 Side leading rear cables option specification 1 7 1 6 Mechanical accuracy 1 8 1 7 Uni directional positional accuracy 1 9 1 8 Encoder resolution 1 10 1 9 Rigidity 1 11 Moment stiff...

Страница 8: ...2 13 Overload detection time 2 14 Chapter 3 Installation 3 1 Receiving inspection 3 1 3 2 Notices on handling 3 2 3 3 Installation location and installation 3 3 Environment of installation location 3...

Страница 9: ...Amplifier Combinations 1 3 1 4 Specifications 1 4 1 5 External drawing 1 6 1 6 Mechanical accuracy 1 8 1 7 Uni directional positional accuracy 1 9 1 8 Encoder resolution 1 10 1 9 Rigidity 1 11 1 10 R...

Страница 10: ...driving various factory automation FA equipment such as robot joints and alignment mechanisms for semi conductor and LCD panel manufacturing devices Main features Slim line body The FHA C mini series...

Страница 11: ...8 C 30 D200 C J Model AC Servo Actuator FHA C mini series Model No 8 11 14 Version symbol Reduction ratio of the HarmonicDrive 30 1 30 50 1 50 100 1 100 With connector standard specification 1 Encoder...

Страница 12: ...l No Input voltage V Encoder type Combined amplifier SSCNET H type FHA C mini 8 AC200 Incremental MR J4 10B RJ920J 11 AC200 14 AC200 MR J4 20B RJ920J 8 AC100 MR J4 10B1 RJ920J 11 AC100 14 AC100 MR J4...

Страница 13: ...ent stiffness N m rad 2 x 10 4 4 x 10 4 8 x 10 4 kgf m rad 0 2 x 10 4 0 4 x 10 4 0 8 x 10 4 Encoding format Incremental encoder Encoder resolution Note 4 pls rev 2 000 8 000 Actuator resolution Note 4...

Страница 14: ...000 Uni directional positional accuracy Sec angle 150 120 120 Mass kg 0 40 Protection structure Totally enclosed self cooled type Environmental conditions Operating temperature 0 to 40 C Storage tempe...

Страница 15: ...f FHA C mini series actuators are shown below Side leading cables standard specification FHA 8C xx D200 CJ FHA 8C xx D200 CEJ Unit mm third angle projection FHA 11C xx D200 CJ FHA 14C xx D200 CJ Hollo...

Страница 16: ...utlines Side leading rear cables option specification Unit mm third gle projection FHA 14C xx D200 CJK FHA 11C xx D200 CJK FHA 8C xx D200 CJK FHA 8C xx D200 CEJK Hollow shaft inside diameter Cable pul...

Страница 17: ...t measures the axial runout maximum runout width of the outermost periphery of output shaft of the output rotary unit per revolution 2 Deflection of output shaft The dial gauge on the fixed part measu...

Страница 18: ...recision control so the positioning error of the motor shaft is compressed to 1 30 1 50 or 1 100 by the gearing The actual angle transmission error of the speed reducer determines the uni directional...

Страница 19: ...cordingly the resolution per a single revolution is 30 50 or 100 times In addition the resolution is electrically multiplied by 4 when an actuator is combined with a dedicated servo amplifier The reso...

Страница 20: ...The moment stiffness is expressed as the tensional moment angle Model Item FHA 8C FHA 11C FHA 14C Moment stiffness N m rad 2 x 10 4 4 x 10 4 8 x 10 4 kgf m rad 0 2 x 10 4 0 4 x 10 4 0 8 x 10 4 kgf m...

Страница 21: ...ge where torque T is T2 or above The table below shows the average value of each actuator Model Item FHA 8C FHA 11C FHA 14C 30 50 100 30 50 100 30 50 100 T1 N m 0 29 0 29 0 29 0 80 0 80 0 80 2 0 2 0 2...

Страница 22: ...000 230 or MR J4W2 0303B MX940J Product Specifications No BCN B72000 227 1 11 Shock resistance The shock acceleration when applying a impact in the up down and left right directions with the center sh...

Страница 23: ...ange allows instantaneous operation like acceleration and deceleration usually The continuous and 50 duty motion ranges shown on each graph are measured on the condition where the radiation plate spec...

Страница 24: ...ing acceleration and deceleration 50 duty range Continuous motion range Rotation speed r min Torque Nm 140 120 80 60 20 0 Motion range during acceleration and deceleration 50 duty range Continuous mot...

Страница 25: ...0 4 0 1 0 3 0 0 50 duty range Motion range during acceleration and deceleration Continuous motion range 250 200 100 50 0 150 Rotation speed r min Torque Nm Radiation plate 150 x 150 x 6 mm FHA 11C 30...

Страница 26: ...0 50 0 150 Rotation speed r min Torque Nm Radiation plate 150 x 150 x 6 mm FHA 11C 30 Input voltage 100V 5 0 4 5 3 5 3 0 1 5 0 5 0 2 0 4 0 2 5 1 0 50 duty range Continuous motion range Continuous moti...

Страница 27: ...on plate 200 x 200 x 6 mm FHA 14C 30 Input voltage 200V 250 200 100 50 0 150 Rotation speed r min 10 9 7 6 3 1 0 4 8 5 2 50 duty range Continuous motion range Continuous motion range Torque Nm Radiati...

Страница 28: ...motion range 140 120 80 60 20 0 40 100 Rotation speed r min Torque Nm Radiation plate 200 x 200 x 6 mm FHA 14C 50 Input voltage 100V 20 18 14 10 4 2 0 8 6 12 16 50 duty range Continuous motion range...

Страница 29: ...en Yellow GRN YEL PE 5 6 Pin position Encoder cable Pin layout Pin No Color Signal name Remarks 1A Green Phase A Phase A output 2A Gray Phase B Phase B output 3A Yellow Phase Z Phase Z output 4A Red 5...

Страница 30: ...1 14 Cable specifications 1 21 1 2 3 4 5 6 7 8 9 10 11 Apx Outlines...

Страница 31: ...he following explains the guidelines for selecting actuators 2 1 Connecting power cables 2 1 2 2 Change in moment of inertia of load 2 2 2 3 Verifying and examining load weights 2 3 2 4 Examining oper...

Страница 32: ...eed the allowable values shown in the table below Actuator model FHA 8C FHA 11C FHA 14C 30 50 100 30 50 100 30 50 100 Reduction ratio 30 50 100 30 50 100 30 50 100 Max rotational speed r min 193 116 5...

Страница 33: ...ertia moment converted to motor shaft which has an effect on servo response is as follows The symbols in the formulas are JS Total inertia moment converted to motor shaft L Ratio of load inertia momen...

Страница 34: ...owable Verifying the static safety coefficient Calculate the static equivalent radial load Po Verify the static safety coefficient fs Specifications of the main roller bearing The following table show...

Страница 35: ...t n Fr t n Fr 2 2 1 1 2 2 2 1 1 1 av The maximum radial load in section t1 is given by Fr1 while the maximum radial load in section t3 is given by Fr3 Formula 3 Average axial load Faav n n 10 3 n n n...

Страница 36: ...kgf Obtained by formula 6 fw Load coefficient See Table 3 Formula 6 Dynamic equivalent radial load av av av av Fa Y dp La Fa R Lr 2 Fr Fr X Pc Symbols used in the formulas Pc Dynamic equivalent radia...

Страница 37: ...radial load Po by formula 9 Formula 10 Static safety coefficient Po Co fs Symbols used in the formulas fs Static safety coefficient See Table 4 Co Basic static rated load N kgf See Table 1 Po Static...

Страница 38: ...For linear operation use the rotation speed conversion formula below Select an appropriate reduction ratio from the 30 50 or 100 series so that the calculated rotation speed does not exceed the maxim...

Страница 39: ...n the graph indicates 20 of the maximum torque Linear operation horizontal operation The rotary torque when the mass W moves horizontally due to the screw of pitch P is shown below T Rotary torque N m...

Страница 40: ...owing operating conditions Rotation speed 100 r min Load inertia moment 0 04 kg m 2 Since the load mechanism is mainly inertia the load torque is negligibly small 1 After applying these conditions to...

Страница 41: ...or and then let it move at a constant speed followed by deceleration by the maximum torque The travel angle per cycle is 120 and the cycle time is 0 8 second 1 KLa KLd Obtain KLa KLd 1 7 in the follow...

Страница 42: ...150 x 150 x 6 mm FHA 8C 50 KL 0 33 0 67 1 1 5 150 100 50 0 4 3 5 3 2 5 2 1 5 1 0 0 5 FHA 11C 100 6 5 4 3 2 0 1 Torque Nm Operable range 100 V 200 V 24 V Rotation speed r min Rotation speed r min Torq...

Страница 43: ...FHA 14C 100 KL 0 33 0 67 1 25 20 5 0 30 1 5 15 10 2 2 5 80 60 40 20 0 250 200 150 100 50 0 Rotation speed r min Nm Radiation plate 200 x 200 x 6 mm FHA 14C 30 KL 0 33 0 67 1 9 6 4 2 0 10 1 5 8 7 5 3 1...

Страница 44: ...fective torque and average rotation speed Use the operating conditions found in example 1 and 2 to get the effective torque and average rotation speed Substituting 8 3 N m for Ta 8 3 N m for Td 0 N m...

Страница 45: ...d detection function of the amplifier even within the allowable duty range This overload detection time is shown in the figure below Input voltage 100VAC 200VAC specification 0 1 1 10 100 1000 0 50 10...

Страница 46: ...ification FHA 8C 0 1 1 10 100 1000 0 50 100 150 200 250 300 FHA DC24V Output torque coefficient Output torque Output torque coefficient x Allowable continuous torque Curved line indicating overload de...

Страница 47: ...e for installing the FHA C mini series actuator 3 1 Receiving inspection 3 1 3 2 Notices on handling 3 2 3 3 Installation location and installation 3 3 3 4 Initial settings for amplifier 3 5 3 5 PL09...

Страница 48: ...wrong immediately contact the dealer 1 The encoder line connectors may only be used for option J actuators 2 The model No of actuators with 24 VDC E input power supply is always 8 FHA 8 C 30 D200 C J...

Страница 49: ...tput shaft 2 Do not put the FHA C mini series actuator on a table shelf etc where the actuator could easily fall 3 The allowable storage temperature is 20 to 60 C Do not expose the actuator to direct...

Страница 50: ...ases water water droplets oil mist etc Protection class Standard products are structurally designed to meet the IP 44 requirements However rotating and sliding areas oil seal areas and connectors are...

Страница 51: ...B MX940J Product Specifications No BCN B72000 227 4 Motor cable and encoder cable Do not pull the cables with a strong force The connection points may be damaged Install the cable wiring with slack so...

Страница 52: ...64 FHA 11C 30 D200 CJ 1A1E FHA 11C 50 D200 CJ 1A32 FHA 11C 100 D200 CJ 1A64 FHA 14C 30 D200 CJ 1B1E MR J4 20B RJ920J MR J4 20B1 RJ920J FHA 14C 50 D200 CJ 1B32 FHA 14C 100 D200 CJ 1B64 FHA 8C 30 D200 C...

Страница 53: ...6 0 FHA 14C 30 D200 CJ 8 4 FHA 14C 50 D200 CJ 12 4 FHA 14C 100 D200 CJ 19 2 FHA 8C 30 D200 CEJ 0 67 FHA 8C 50 D200 CEJ 1 44 FHA 8C 100 D200 CEJ 2 38 If the servo amplifier outputs the AL27 1 Initial m...

Страница 54: ...3 5 PL09 Magnetic pole detection level setting Installation 3 7 1 2 3 4 5 6 7 8 9 10 11 Apx Installation...

Страница 55: ...4 Option Options you can purchase as necessary are explained in this chapter 4 1 Extension cable 4 1 Chapter...

Страница 56: ...r 10m 1 For encoder EWC Exx A12 3M10 M 100 200 VAC type Pin No Color Signal name Pin No Color Signal name 1A Blue Phase A 1B White Phase A 2A Yellow Phase B 2B Brown Phase B 3A Green Phase Z 3B Black...

Страница 57: ...nal name 1A Blue Phase A 1B White Phase A 2A Yellow Phase B 2B Brown Phase B 3A Green Phase Z 3B Black Phase Z 4A Red 5V 4B Gray GND 5A 5B 6A Shield FG 6B Pin No Color Signal name Pin No Color Signal...

Страница 58: ...10 11 Apx Option 2 For motors EWC Mxx A06 TMC M 100VAC 200VAC specification Install the connector supplied with the servo amplifier Pin No Color Signal name 1 Red U 2 White V 3 Black W 4 Green Yellow...

Страница 59: ...to the MR J4W2 0303B6 MX940J amplifier has 1 shaft When the actuator connected to the MR J4W2 0303B6 MX940J amplifier has 2 shafts Pin No Color Signal name 1 Blue Phase A 2 Yellow Phase B 3 Green Phas...

Страница 60: ...4 1 Extension cable Option 4 5 1 2 4 4 5 6 7 8 9 10 11 Apx Option...

Страница 61: ...5 Appendix This chapter explains the default settings etc Apx 1 Unit conversion Apx 1 Apx 2 Calculating inertia moment Apx 3...

Страница 62: ...ft min 2 ft s 2 in s 2 Factor 2 78 x 10 4 8 47 x 10 5 0 3048 0 0254 Unit m min 2 ft min 2 ft s 2 in s 2 Factor 3600 1 18 x 10 4 3 281 39 37 SI system m s 2 4 Force SI system N Unit kgf lb force oz for...

Страница 63: ...m 2 Unit kgf m s 2 kgf cm s 2 lb ft 2 lb ft s 2 lb in 2 lb in s 2 oz in 2 oz in s 2 Factor 0 102 10 2 23 73 0 7376 3 42 x 10 3 8 85 5 47 x 10 4 141 6 Unit kgf m s 2 kgf cm s 2 lb ft 2 lb ft s 2 lb in...

Страница 64: ...tia gravity center Cylinder Circular pipe Slanted cylinder Ball Ellipsoidal cylinder Cone Rectangular pillar Square pipe R L z x y L R m 2 2 R m 2 1 Ix 3 L R m 4 1 Iy 2 2 3 L R m 4 1 Iz 2 2 R1 L R2 z...

Страница 65: ...different from the gravity center I Inertia moment when the gravity center axis does not match the rotational axis kg m2 Ig Inertia moment when the gravity center axis matches the rotational axis kg m...

Страница 66: ...oment 2 2 Apx 3 Inertia moment of a cylinder 6 Initial settings for amplifier 3 5 Load 2 3 Load torque 2 9 Magnetic pole detection level setting 3 6 Maximum load 2 3 Model 1 2 Operating rotation speed...

Страница 67: ...d or replaced free of charge This limited warranty does not apply to any product that has been subject to 1 Improper handling or use by the customer 2 Modification or repair carried out other than by...

Страница 68: ...armonic Drive AG Hoenbergstrasse 14 65555 Limburg Germany TEL06431 5008 0 FAX06431 5008 18 Harmonic Drive L L C 247 Lynnfield Street Peabody MA 01960 U S A TEL 1 978 532 1800 FAX 1 978 532 9406 1805 1...

Отзывы: