39
MAINTENANCE
Removing the Glass Front
Remove the decorative face as described on page 15.
Lift the latches shown above and tilt the glass out at the
top and lift it out of the groove at the bottom. Handle
the glass with care.
A qualified service person recommended by your
Harman dealer should conduct an annual inspection
and maintenance of your fireplace, it’s venting, and the
installation to keep it running safely and efficiently.
The following procedures should be performed only
by a qualified service person. The gas supply should
be turned off whenever a maintenance procedure is
performed.
If the glass front, side doors, or front access door are
removed for servicing, they must be replaced prior to
operating the fireplace.
Latches
Slot
WARNING: DO NOT OPERATE THIS
APPLIANCE WITH THE GLASS FRONT
REMOVED, CRACKED OR BROKEN.
REPLACEMENT OF GLASS SHOULD BE
DONE BY A LICENSED OR QUALIFIED
S E RV I C E P E R S O N . N E V E R U S E
SUBSTITUTE MATERIALS.
DO NOT STRIKE OR SLAM GLASS
Replacing the Gasket
The Serenity uses part no. 3-44-00539 fiberglass gasket
in the front door. Should it ever need replacement, use
only the proper replacement gasket that is available
from your Harman dealer. To replace the gasket, follow
this procedure.
1. Lay glass front face down.
2. Bend four tabs up far enough to remove the glass.
3. Remove old gasket.
4. Install new gasket around glass.
5. Place glass back in frame.
6. Bend tabs to secure glass. Not too tight.
7. Reinstall glass door by placing the flange on the
bottom of the door into the groove on the bottom of
the fireplace opening. Next lift the latches and push
the door against the unit. Pull the spring loaded
latches front until the tabs drop into the slots on the
door frame.
Cleaning the Glass
The glass may be cleaned with ordinary household
glass cleaner and a soft cloth or paper towel.
WARNING: Never clean the glass when it is hot. Do
not use abrasive cleaners on the glass.
Inspecting the Venting
An inspection of both the inner and outer pipes of
the venting system should be made during the annual
service appointment. They must have no blockage and
be in good repair. The vent manufacturer’s instructions
may provide specific suggestions or details on vent
inspection. Any sections that are taken apart for the
inspection must be reassembled and sealed as required.
Cleaning the Log Set and Firebox
During the annual inspection and maintenance
appointment, the service person should clean dust, lint,
and any light accumulation from the logs and the firebox
area. An extra-soft brush should be used on the logs as
they are extremely fragile; a vacuum cleaner may be
used on the firebox. If at any time the logs cannot be
removed or installed without forcing, the cause must be
found. The logs must never be forced.
Содержание The Serenity III HB 38 DV
Страница 27: ...VENTING Only For Qualified Installers 27...
Страница 54: ......