background image

VENTING

Only For Qualified Installers

19

length 6” (Galvalume)   

 

SV4l6   

908 

 

 

SV5l6   

 

1208

length 6” (Black) 

 

 

SV4lB6 

908B   

 

SV5lB6 

 

1208B

length 12” (Galvalume)  

 

SV4l12  

906 

 

 

SV5l12  

 

1206 

length 12” (Black) 

 

 

SV4lB12 

906B   

 

SV5lB12 

 

1206B

length 24” (Galvalume)  

 

SV4l24  

904 

 

 

SV5l24  

 

1204 

length 24” (Black) 

 

 

SV4lB24 

904B   

 

SV5lB24 

 

1204B

length 36” (Galvalume)  

 

SV4l36  

903 

 

 

SV5l36  

 

1203 

length 36” (Black) 

 

 

SV4lB36 

903B   

 

SV5lB36 

 

1203B

length 48” (Galvalume)  

 

SV4l48  

902 

 

 

SV5l48  

 

1202 

length 48” (Black) 

 

 

SV4lB48 

902B   

 

SV5lB48 

 

1202B

Adj. length (Galv.)(Adjustable 6”) 

SV4lA   

n/a 

 

 

SV5lA   

 

n/a 

Adj. length (Blk)(Adjustable 6”)   

SV4lBA 

n/a 

 

 

SV5lBA 

 

n/a

Adj. length (Galv.)(Adjustable 12”) 

SV4lA12 

n/a 

 

 

SV5lA12 

 

n/a 

Adj. length (Blk)(Adjustable 12”) 

SV4lBA12 

n/a 

 

 

SV5lBA12 

 

n/a

Adj. length (Galv.)(Adjustable 24”) 

SV4lA24 

917 

 

 

SV5lA24 

 

1217 

Adj. length (Blk)(Adjustable 24”) 

SV4lBA24 

917B   

 

SV5lBA24 

 

1217B

Swivel 45

o

 elbow (Galvalume)   

SV4e45 

945G   

 

SV5e45 

 

1245G 

Swivel 45

o

 elbow (Black) 

 

SV4eB45 

945BG   

 

SV5eB45 

 

1245BG 

Rigid 45

o

 elbow (Black)   

 

SV4eBR45 

945B   

 

SV5eBR45 

 

1245B 

Swivel 90

o

 elbow (Galvalume)   

SV4e90 

990G   

 

SV5e90 

 

1290G 

Swivel 90

o

 elbow (Black) 

 

SV4eB90 

990BG   

 

SV5eB90 

 

1290BG

Rigid 90

o

 elbow (Black)   

 

SV4eBR90 

990B   

 

SV5eBR90 

 

1290B

Adjustable Decorative 

Square Cathedral Support 

 

SV4CSB 

941 

 

 

SV5CSB 

 

1241

Collar for the Decorative 

Square Cathedral Support 

 

SV4AC  

n/a 

 

 

SV5AC  

 

n/a

Decorative Black Plate (square)  

SV4PF   

940 

 

 

SV5PF   

 

1240

Universal Support 

 

 

SV4SU  

989 

 

 

SV5SU  

 

1289

Floor Support   

 

 

SV4SD  

n/a 

 

 

SV5SD  

 

n/a

Roof Brace 

 

 

 

SV4BS  

n/a 

 

 

SV5BS  

 

n/a

Roof Support   

 

 

SV4ST   

n/a 

 

 

SV5ST   

 

n/a

Wall Band 

 

 

SV4BM  

988 

 

 

SV5BM  

 

1288

Attic Radiation Shield   

 

SV4RSA 

n/a 

 

 

SV5RSA 

 

n/a

Wall Radiation Shield   

 

SV4RSM 

942 

 

 

SV5RSM 

 

1242

Firestop 

 

 

 

SV4BF   

963 

 

 

SV5BF   

 

1263

Flat Roof Flashing(storm collar incl.) 

SV4F   

943F   

 

SV5F   

 

1243F

Adjustable Roof Flashing

1/12 - 7/12 (storm collar incl.)   

SV4FA   

943 

 

 

SV5FA   

 

1243

Adjustable Roof Flashing

8/12 - 12/12 (storm collar incl.)   

SV4FB   

943S   

 

SV5F  B 

 

1243S

Storm Collar 

 

 

 

SV4FC  

953 

 

 

SV5FC  

 

1253

Vinyl Shield Protector   

 

SV4VS  

950 

 

 

SV5VS  

 

1250

Restrictor Disk   

 

 

SV4RD  

929 

 

 

SV5RD  

 

n/a

VeRTICAl TeRMINATIoN CAP  

SV4CGV 

980 

 

 

SV5CGV 

 

1280 

HoRIZoNTAl TeRMINATIoN CAP 

SV4CHC-1 

984 

 

 

SV5CHC-1 

 

1284

SNoRKel  CAP 14” 

 

 

SV4STC14 

982 

 

 

SV5STC14 

 

1282 

SNoRKel  CAP 36” 

 

 

SV4STC36 

981 

 

 

SV5STC36 

 

1281 

Secure VenT DIrecT VenT SYSTeM - 4” x 6-5/8” and 5” x 8”                          

  cross reference list

Secure

 Vent 

cat no.

Simpson Dura-Vent

Direct Vent gS

Stock no.

Secure

 Vent

 

cat no.

Simpson Dura-Vent

Direct Vent gS

Stock no.

Description

Содержание The Serenity III HB 38 DV

Страница 1: ...TABLE FOR INSTALLATION IN MOBILE HOMES IF THIS fireplace IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT...

Страница 2: ...o not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructi...

Страница 3: ...ace Installation 15 Venting 17 Damper Settings 28 Changing to LP 29 Log Placement 31 Option Installation Thermostat 32 Remote Control 32 Remote Register Kit 33 Maintainence 39 Wiring Diagrams 41 Troub...

Страница 4: ...uilding code agency and insurance representative before you begin your installation to ensure compliance with local codes including the need for permits and follow up inspections Several issues must b...

Страница 5: ...xchanger producing two to three times more air than other brands of gas fireplaces Blower Off Blower On Air Gate Blower System Typically in gas fireplaces the blower which is usually an option is plac...

Страница 6: ...6 OPERATION Refer to actual label for important instructions and safety concerns This label can be found in the bottom of the fireplace next to the blower...

Страница 7: ...elow 10 Push the control knob in fully and hold Immediately push the red piezo ignitor button to light the pilot It is normal to have to push the red button several times before the pilot ignites Cont...

Страница 8: ...4 Push in the gas control knob slightly and turn it clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in slightly Do not force it FLAME HEIGHT ADJUSTMENT There are...

Страница 9: ...ndoffs RATINGS Natural Propane Input Rating Btu hr 0 4500 ft 0 1375 m 43500 43500 Min Input Rating Btu hr 0 4500 ft 0 1375 m 23300 23800 Orifices DMS front rear 0 4500 ft 0 1375 m 31 51 52 59 Manifold...

Страница 10: ...rch Hood This fireplace may be placed on a wood floor Hearth is not required in front of the fireplace MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION Unit to floor 0 in Face to side wall 7 in Unit t...

Страница 11: ...11 SPECIFICATIONS 42 095 47 595 42 376 43 085 1 000 1 000 32 662 21 135 22 135 10 865 6 865 10 270 10 270 10 894 7 917 Corner Gas In Electrical Hook up 6 3 6 7 9...

Страница 12: ...way to install this fireplace This is why it is important to have a qualified installer do the installation The Serenity III can be laid in stone brick or other masonry products For this purpose a spe...

Страница 13: ...hearth 4 One two or no remote duct kits 5 Thermostat position 6 Gas line hook up is on the right side 7 Electrical hook up is on the left side This appliance must be electrically connected and ground...

Страница 14: ...ible material may be used in front of the Dura rock The total thicknes for all layers of facing material may not exceed one inch A one inch space under the front edge of the fireplace allows room for...

Страница 15: ...tom rear of the face into the hook slots on the fireplace Next with the top latch handles in the horizontal position push the face against the fireplace and swing the latches straight down causing the...

Страница 16: ...as supply line are essential for the safe and efficient performance of this appliance Make sure that the plumber or gas supplier checks the gas supply line and gas pressure at installation NOTE Improp...

Страница 17: ...4 984 1284 Horizontal Square Termination 980 1280 Vertical Termination 991 1291 Vertical Termination High Wind 950 1250 Vinyl Siding Standoff 1222D Only available from Harman 8 x 5 to 6 5 8 x 4 Adapto...

Страница 18: ...lack 4DT 9 9 Pipe Length Galvanized 4DT 9B 9 Pipe Length Black 4DT 12 12 Pipe Length Galvanized 4DT 12B 12 Pipe Length Black 4DT 18 18 Pipe Length Galvanized 4DT 18B 18 Pipe Length Black 4DT 24 24 Pip...

Страница 19: ...igid 90o elbow Black SV4EBR90 990B SV5EBR90 1290B Adjustable Decorative Square Cathedral Support SV4CSB 941 SV5CSB 1241 Collar for the Decorative Square Cathedral Support SV4AC n a SV5AC n a Decorativ...

Страница 20: ...MFL18 24 flex section female female MFL2 36 flex section female female MFL3 48 flex section female female MFL4 Elbows 45 solid elbow section female male connectors EEL45 90 elbow female female MEL90F...

Страница 21: ...of MRF 12 Flashing and storm collar for 7 12 to 12 12 pitch roof Bulk pack of 6 MRF1206 Horizontal Vent Restrictors For 8 14 horizontal vent run MHVR8 For 15 24 horizontal vent run MHVR15 For 25 35 ho...

Страница 22: ...n female male PEXT6 Flex Sections 12 flex section female female connectors PFL1 18 flex section female female PFL18 24 flex section female female PFL2 36 flex section female female PFL3 48 flex sectio...

Страница 23: ...upport plate support ring Bulk pack of 6 PSP806 Flashing and storm collar for 1 12 to 7 12 pitch roof PRF7 Flashing and storm collar for 1 12 to 7 12 pitch roof Bulk pack of 6 PRF706 Flashing and stor...

Страница 24: ...tract five feet of total horizontal pipe length for second elbow Venting with 8 x 5 Pipe A combination of one 900 elbow and two 450 elbows is allowed Subtract three feet of total horizontal pipe lengt...

Страница 25: ...bow and two 450 elbows is allowed Subtract three feet of total horizontal pipe length for each 450 elbow used Vent termination must remain within the shaded area regardless of configuration Use Adapto...

Страница 26: ...6 inches 15 cm for appliances 10 000 Btuh 3 kW 12 inches 30 cm for appliances 10 000 Btuh 3 kW and 100 000 Btuh 30 kW 36 inches 91 cm for appliances 100 000 Btuh 30 kW 6 feet 1 83 m 7 feet 2 13 m 12...

Страница 27: ...VENTING Only For Qualified Installers 27...

Страница 28: ...65 8 X 4 Vent A vent damper is provided to allow fine tuning of the draft Too little draft will cause flames to be too long with black tips and too much draft will cause flames to be short and blue T...

Страница 29: ...rew Remove Flame Bridge Lift up on front of burner grate screen assembly and then slide left about 1 2 The assembly can then be removed Remove Rear Burner by sliding to the left 1 2 3 5 4 6 7 8 Top Ve...

Страница 30: ...ce Control Panel to the left 11 12 13 Read instructions packed with LP Change over Kit Place conversion sticker provided in Kit on bottom of valve This is to permanently mark the valve that it has bee...

Страница 31: ...r log down over the two pins to locate the log Place the front log down over the pin shown above The front of the log should be parallel with the grate bar Place the side log as shown with the notch i...

Страница 32: ...d and maintained a millivolt control system should give many years of trouble free service It is important to use wire of a gauge proper for the length of the wire RECOMMENDED WIRE GAUGES Maximum Wire...

Страница 33: ...o 3 x 10 Transition Remote Register Box With Blower Speed Control 3 x 10 Duct not part of kit Register Kit Includes remote register box with blower speed control two 8 foot sec tions of 6 flex pipe 6...

Страница 34: ...installing the damper assembly 2 Cut the yellow insulation around the edge of the opening Discard the cutout 3 Remove bottom cover by removing the screw in the angle at the bottom of the hole After t...

Страница 35: ...all cavity as a duct Run wires to blower as shown in wiring diagram on page 42 Mount blower assembly in box as shown Test blower Note Blower will not run until fireplace is hot Mount blower cover as s...

Страница 36: ...Speed Control Access Door Floor Register Installation The difference between the wall register and floor register is the register itself and the mounting brackets The wall register mounts on the wall...

Страница 37: ...floor joists 2 Place the mounting bracket in the hole as shown The tapered end of the bracket must be opposite to the side where the air will enter the blower box 3 Place the blower box with blower a...

Страница 38: ...r a variation in floor thickness 9 Turn on electrical power and test Operation Note A temperature switch on the fireplace will not allow the register blower to start if the fireplace is not warm enoug...

Страница 39: ...tabs up far enough to remove the glass 3 Remove old gasket 4 Install new gasket around glass 5 Place glass back in frame 6 Bend tabs to secure glass Not too tight 7 Reinstall glass door by placing the...

Страница 40: ...unobstructed Use a small drill or wire to clean any obstructed holes Remove any rust or other buildup that may have accumulated Replace burners in reverse order Lubrication The Serenity Fireplace doe...

Страница 41: ...LUE ORANGE TOP MID BOTTOM RED OR BLUE TWISTED WIRE BATTERY LEADS ON CENTER TERMINALS RED OR BLUE TWISTED WIRE TO REAR BURNER VALVE REAR BURNER ON OFF SWITCH POLARITY REVERSING JUMPERS REAR BURNER SWIT...

Страница 42: ...AMP MAXIMUM CIRCUIT RECOMENDED CUSTOMER INSTALLED 14 2 ROMEX or equivalent TO 2nd AUX DUCT BLOWER TO 1st AUX DUCT BLOWER WHITE BLACK BLACK WHITE GREEN VARIABLE SPEED SWITCH OPTIONAL AUX DUCT BLOWER B...

Страница 43: ...SYSTEM MODULE STATES THE FUEL FOR WHICH THE HEATER IS EQUIPPED MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUC TION Unit to floor 0 in Face to side wall 7 in Unit to top stand offs 0 in Unit to side stan...

Страница 44: ...left Front 3 40 08706 4 Twig 3 40 08708 5 Floor Brick left 3 40 08709 6 Blower Assembly 1 10 47120 Y 7 Switch Momentary Rear Burner 3 20 08765 8 Variable Speed Control w off 3 20 02223 9 Rocker Wwitch...

Страница 45: ...302A Floor Register Kit option no longer available 1 00 4238318 Gas Bridge 2 00 4238212B Gasket 3 16 x 5 8 Flat 10 Ft 1 00 08792 Gasket Glass 10 Ft 1 00 00539 Y Gasket Silica explosion Relief 3 44 087...

Страница 46: ...dered from an authorized dealer Stocked at Depot ITeM DeScrIPTIOn cOMMenTS ParT nuMBer Screw HCS 5mm x 8mm Zinc Pkg of 50 3 30 1000 50 Y Snap Disc Control opens 115 closes 130 3 20 49812 Y Solenoid 3...

Страница 47: ...LE SHOOTING Only For Qualified Installers Manifold Pressure 10 inches Inlet Pressure 11 to 13 inches Manifold Pressure 3 5 inches Inlet Pressure 5 to 7 inches Natural Gas Propane Pilot Adjuster Pilot...

Страница 48: ...lace Ignitor wire Yes No Bad OK OK Bad No Yes Turn on gas valve Is gas turned on Yes OK Purge gas line to stove No Replenish supply Bad OK Replace Piezo Ignitor Check Piezo Ignitor to make sure the sm...

Страница 49: ...d Check Milivolt output of thermocouple Should be 10 or more MV Check inlet pressure Bad Adjust pilot adjustment to achieve proper flame Replace Thermocouple Bad Replace Valve Pilot does not stay lit...

Страница 50: ...position Is Pilot lit no Light pilot Yes Check Thermopile voltage at terminals marked TP on valve Should be approximately 200 mv with switch on and approximately 400 mv with switch off too low Replac...

Страница 51: ...batteries Bad Repair any loose connections Replace switch Bad Replace solinoid Check wire connections Bad Install new batteries Good Rear burner does not light Do you hear a click sound when you move...

Страница 52: ...truction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlie...

Страница 53: ...t of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enamel...

Страница 54: ......

Отзывы: