7
OPERATION
Operation
HOW TO LIGHT THE FIRE
1. STOP! Read the safety information on the front cover.
2. If using the optional thermostat, set the thermostat to
it’s lowest setting.
3. Turn off all electrical power to the appliance.
4. Turn the ON-OFF/THERMOSTAT switch to the OFF
position.
5. Push in the gas control knob slightly and turn it
clockwise to “OFF.” NOTE: THE KNOB CANNOT
BE TURNED FROM “PILOT” TO “OFF” UNLESS
IT IS PUSHED IN SLIGHTLY. DO NOT FORCE IT.
6. Wait five (5) minutes to clear out any gas. If you
then smell gas, STOP! Follow steps in the safety
information on page 2. If you don’t smell gas, go to
the next step.
7. Set the High-Low Regulator to High by turning it
fully counterclockwise.
8. Press in the gas control knob slightly and turn it
counter-clockwise to “PILOT.”
9. Locate the pilot near the center of the firebox as
shown below.
10. Push the control knob in fully and hold. Immediately
push the red piezo ignitor button to light the pilot.
It is normal to have to push the red button several
times before the pilot ignites. Continue to hold the
control knob in for about one(1) minute after the pilot
is lit. Release the knob and it will pop back up. The
pilot should remain lit. If it goes out, repeat steps 5
through 9.
•If the knob does not pop up when released, stop and
immediately call your service technician or gas supplier.
•If the pilot will not stay lit after several tries, turn the gas
control knob to “OFF” and call your service technician
or gas supplier.
11. Turn the gas control knob counterclockwise to “ON.”
12. Place the ON-OFF/THERMOSTAT switch in the
ON position or in the THERMOSTAT position if the
optional thermostat is used.
13. Restore electrical power to the heater.
14. Set the optional thermostat to the desired temperature.
Gas Control
High-Low
ON-OFF/
THERMOSTAT
Switch
Three Speed
Blower Switch
Piezo Ignitor
Button
Rear Burner
ON/OFF
Switch
PILOT
Содержание The Serenity III HB 38 DV
Страница 27: ...VENTING Only For Qualified Installers 27...