background image

36

P68 Pellet Stove

4021-645C 12-29-10 

Page 2 of 2

WARRANTY CONDITIONS:

•  This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of 

HHT authorized dealers is available on the HHT branded websites.

•  This warranty is only valid while the HHT appliance remains at the site of original installation.

•  Contact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contact 

the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking warranty service 

from a dealer other than the dealer from whom you originally purchased the product.

•  Check with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping charges 

for parts are not covered by this warranty.

This warranty is void if:

•  The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or other damaging 

chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, rust colored cast iron, bubbling, 

cracking and discoloration of steel or enamel finishes.

•  The appliance is subjected to prolonged periods of dampness or condensation.

•  There is any damage to the appliance or other components due to water or weather damage which is the result of, but 

not limited to, improper chimney or venting installation. 

LIMITATIONS OF LIABILITY:

•  The owner’s exclusive remedy and HHT’s sole obligation under this warranty, under any other warranty, express or 

implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above. In no 

event will HHT be liable for any incidental or consequential damages caused by defects in the appliance. Some states 

do not allow exclusions or limitation of incidental or consequential damages, so these limitations may not apply to you. 

This warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TO 

THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY 

SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE 

EXPRESSED WARRANTY SPECIFIED ABOVE.

WARRANTY EXCLUSIONS:

This warranty does not cover the following:

•  Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and 

exterior surface finishes may occur. This is not a flaw and is not covered under warranty.

•  Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items, 

or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes.

•  Repair or replacement of parts that are subject to normal wear and tear during the warranty period. These parts 

include: paint, wood, pellet and coal gaskets, firebricks, grates, flame  guides, light bulbs, batteries and the discolor

-

ation of glass.

•  Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and com

-

plaints related to this noise are not covered by this warranty.

•  Damages resulting from: (1) failure to install, operate, or maintain the appliance in accordance with the installation 

instructions, operating instructions, and listing agent identification label furnished with the appliance; (2) failure to 

install the appliance in accordance with local building codes; (3) shipping or improper handling; (4) improper opera

-

tion, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/ 

incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting 

caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or 

forced air furnaces or other such causes; (6) use of fuels other than those specified in the operating instructions; (7) 

installation or use of components not supplied with the appliance or any other components not expressly authorized 

and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing; 

and/or (9) interruptions or fluctuations of electrical power supply to the appliance.

•  Non-HHT venting components, hearth components or other accessories used in conjunction with the appliance.

•  Any part of a pre-existing fireplace system in which an insert or a decorative gas appliance is installed.

•  HHT’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Informa

-

tion is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consider

-

ation must be given to appliance location and configuration, environmental conditions, insulation and air tightness of 

 the structure.

Содержание P68

Страница 1: ...A SUITABLE FOR INSTALLATION IN MOBILE HOMES IF THIS pellet STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIA...

Страница 2: ......

Страница 3: ...sp ci ques locales concernant les pr cautions requises lors de la travers e d un mur ou d un plafond Contr ler et nettoyer fr quemment tout le systeme d evacuation des fum es conform ment aux recomma...

Страница 4: ...stove design technology and manufacturing This 68 000 BTU stove has the highest output smartest controls widest heating range and minimal maintenance The P68 s huge output is managed by a microproces...

Страница 5: ...ating season and at the end of each winter for the stove to work efficiently See cleaning instructions on page 23 Mobile Manufactured Home Standards Do Not Allow Installation In Rooms Designated For S...

Страница 6: ...above the burnpot Flame Guide Install the cast iron flame guide on top of the burn pot Make sure that the flame guide is fully seated on the vertical sides of the burn pot and that the back of the gui...

Страница 7: ...check for possible restrictions or the need for outside air see page 10 For more information on the draft test procedure refer to Page 21 Mobile Home Installation When installing this unit in a mobile...

Страница 8: ...hin 3 feet 90 cm above a gas meter regulator assembly when measured from the horizontal center line of the regulator 1 I The clearance to service regulator vent outlet must be a minimum of 6 feet 1 J...

Страница 9: ...is not achieved For this reason and the fact that the P68 operates with a positive vent pressure we specify that the joints also be sealed with high temp RTV silicone Aluminum tape can also be used f...

Страница 10: ...he flue outlet is more than 12 from the inlet cover The maximum length run of this pipe is 15 feet If a longer run is needed the size must be increased to 3 Inlet cover part number 1 10 08542 should b...

Страница 11: ...throughs 1 Preferred method This method provides excellent venting for normal operation and allows the stove to be installed closest to the wall Two inches from the wall is safe however four inches a...

Страница 12: ...draft in the event of a power failure If the chimney condition is questionable you may want to install a liner as in method 6 The chimney should be inspected and cleaned before installing your stove I...

Страница 13: ...used by the manufacturer Pipe size should be increased to 4 using this method Chimney must be of a type suitable for use with solid fuel 7 Installing into an existing chimney This method provides exce...

Страница 14: ...ell in the room in the event of power failure Min above ground level 18 Venting Fig 15 Fig 14 PL vent manufacturer s firestop spacer and support See Page 7 for corner installation clearances Storm col...

Страница 15: ...lect either Auto or Manual modes for the igniter using the igniter toggle switch When the toggle switch is in the Auto position the igniter located inside the burn pot is ready to automatically light...

Страница 16: ...and smoke will escape through window and door gaskets When the igniter toggle switch is set to manual in this mode the distribution blower will not turn on with a temperature dial setting from 1 to 5...

Страница 17: ...n to Stove Mode and put the fan on H Set the Temperature Dial to 7 Allow the unit to burn for about 30 minutes and check ash on front of burn pot Fig 18 If the ash line is larger than 1 turn the feed...

Страница 18: ...e The advantage of this mode is to allow the operator to have a large viewing fire without blowing extra heat into the room During operation with the temperature dial set at 4 or less the distribution...

Страница 19: ...r 30 minutes of burn time and check again If at 6 setting a 1 or less ash bed is not obtainable it is not a problem The 1 ash bed is only at maximum burn rate and at most normal settings the ash bed w...

Страница 20: ...icate errors listed below Indicates power to distribution blower Status light error messages 3 Blinks Indicates an incomplete ESP circuit or that the ESP Exhaust Sensing Probe Has gone out of range a...

Страница 21: ...to operate Combustion Motor Speed Control Low draft only set point The small straight screwdriver slot is plastic therefore the unit can be adjusted while in operation Fig 22 Fig 23 A simple draft te...

Страница 22: ...room air being drawn into the distribution fan NOTE Distances of more than 25 feet from the unit or in another room are not recommended The room sensor is essential for the P68 s excellent efficiency...

Страница 23: ...is cold and shut down when removing ash pan 1 Pull on latch handle and remove ash pan Use ash pan handle to carry and dispose of ashes 2 Slide the ash pan back into the stove and latch the door by pu...

Страница 24: ...out plate Latch open with blower cover partly removed Burn pot clean out is open Latch closed with blower cover in place Burn pot clean out is closed Fig 29 Fig 28 ESP Probe 5 Open burn pot clean out...

Страница 25: ...lated male female wire connectors These connections between the hot leads the wires inside the burn pot and the cold leads the wires from the control board are always pulled to the inside rear of the...

Страница 26: ...the gasket channel should be free of all loose particles The gasket cement used to hold the gasket in place is RTV HIGH TEMPERATURE silicone Put a bead of RTV silicone in the bottom of the gasket chan...

Страница 27: ...tainers and screws Apply the gasket material to the face of the new glass Lay the glass into the door making sure that the glass is contained within the channels and raised areas of the door itself La...

Страница 28: ...el in hopper 2 Draft is too low blocked flue 3 Something is restricting fuel flow 4 Hopper lid not closed properly 5 Feed motor or combustion blower has failed SMOKE IS VISIBLE COMING OUT OF VENT 1 Ai...

Страница 29: ...tends to cool the appliance thus robbing heat from your home Damp pellet fuel could turn back into sawdust which does not flow properly through the feed system Size Pellets are either 1 4 inch or 5 1...

Страница 30: ...auge steel This is the minimum size for floor protection with this unit Part 1 00 06727 Hopper Extension The hopper extension allows you to put more pellet fuel in the hopper and extends burn time on...

Страница 31: ...for samples The Brushed Stainless deer cutout pictured below is another option available This cutout reveals the color of the stove through the cut out shapes On the rear of the stove hopper there is...

Страница 32: ...UND P O W E R C O R D 1 8 3 R U B B E R C O R D WHITE GREEN BLUE GREEN WHITE RED MALE FEMALE CONNECTIONS BROWN WHITE N O CONTACTS MALE FEMALE CONNECTIONS LT BLUE LT BLUE INSIDE BURNPOT IGNITER ELEMENT...

Страница 33: ...o 2 or 3 Set temperature knob to desired amount Turn mode selector knob onto Room Temp mode After the fire has lit watch that the fuel does not feed too fast that it pushes the red glowing fuel bed of...

Страница 34: ...continued operation Your appliance will recognize when power is restored What happens depends on ESP temperature and whether it is equipped with automatic ignition in automatic setting units equipped...

Страница 35: ...home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occ...

Страница 36: ...as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated...

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ......

Страница 41: ......

Страница 42: ...42 P68 Pellet Stove Service Maintenance Log...

Страница 43: ......

Страница 44: ...00 Recycled Paper At Harman we build each product to a standard not a price Signature of Boxer Your premium quality hearth product designed and assembled by the experienced and skilled members at Harm...

Отзывы: