7
P68 Pellet Stove
installing
Place the stove on a noncombustible type floor or floor
protector that extends a minimum of 6 inches (152mm) to the
front of the load door opening, 6 inches (152mm) to the sides
of the door opening, and 6 inches to the rear. Floor protection
must also extend 2 inches (51mm) beyond each side of any
horizontal flue pipe. The minimum floor protector material
is 20 gauge sheet metal. Other floor protector materials are
ceramic tile, stone, brick, etc.
Place the stove away from combustible walls at least as far
as shown in Figures 3, 4, and 5. Please note the difference in
side wall clearance with and without side shields.
Note that the clearances shown are minimum for safety but
do not leave much room for access when cleaning or servicing.
Please take this into account when placing the stove.
Connect the power cord to a 120 V.A.C. 60Hz grounded
receptacle. (A surge protector is recommended to protect the
circuit board.) Also be sure that the polarity of the outlet that
the stove is plugged into is correct.
Prior to installing the flue pipe, connect a draft meter. (The
draft meter must have a minimum range of 0 - .5") Record the
first reading. Connect flue pipe to stove and be sure all doors
and windows in the home are closed. Record the second
draft reading_______. If the second reading is more than .05"
lower than the first reading, check for possible restrictions or
the need for outside air (see page 10). For more information
on the draft test procedure, refer to Page 21.
Mobile home installation
When installing this unit in a mobile home, several
requirements must be followed:
1. The unit must be bolted to the floor. This can be done with
1/4" lag screws through the 2 holes in the base plate.
2. The unit must also be connected to outside air. See page 10.
3. Floor protection and clearances must be followed as shown.
4. Unit must be grounded to the metal frame of the mobile
home.
5. Be sure to follow the vent manufacturer's guidelines to
provide for a sufficient vapor barrier where the flue penetrates
the outside.
6. The top section of any chimney or venting must be removable
to a height of 13' (3.9 M) to allow for transport.
7. The factory-built chimney must conform to CAN/ULC-S629,
Standard for 650°C Factory-Built Chimneys.
caution: this appliance must be vented to the outside.
Clothing and other flammable materials should not be placed
on or near this unit.
installation
Fig. 3
9"(228mm)-
13"(330mm)
9"(228mm)With Side Shields
13"(330mm) Without Side Shields
9"(228mm)-
13"(330mm)
Fig. 4
2"(51mm)
14"
(355mm)
36"(914mm)
Fig. 5
2"(51mm)
36"(914mm)
20"(508mm)
Floor Protection must also be placed under any
horizontal venting, extending 2" (51mm) beyond
each side of the vent pipe.
Fig. 6
6"
152 mm
6" (152mm)
from
pedestal
base
25" minimum
33" minimum
6" (152mm)
from door
opening
do not inStall in SleePing rooM
Warning
the Structural integrity oF the
ManuFactured hoMe Floor, Wall, and
ceiling/rooF MuSt be Maintained
caution