background image

Martin® ELP WW User Manual 

25 

Control menus 

To access the control menus, press the MENU button. Use the UP and DOWN buttons to navigate 
the menus. Select any required menu option using the ENTER button. For more information, see 
‘Using the control menus’ on page 31. 

Default fixture settings are shown in 

bold

Top Menu 

Menu level 2 

Menu level 3 

Menu level 4 

Notes 

DMX Setup 

DMX Addr 

- XXX 

DMX address 

(default 

address = 1)

. The 

DMX address range is 
limited so that the 
fixture will always have 
enough DMX 
channels within the 512 
available. 

DMX Mode 

1CH/2CH/

4CH

 

 DMX control mode 

Personality Stand-Alone 

Off 

Master 

Fixture acts as master 
in master/

client

 

operation - DMX/RDM 
signal will override 
master/

client

 operation 

Client

Fixture copies master in 
master/

client

 operation 

- DMX/RDM signal will 
override master/

client

 

operation 

Dim Curve 

Linear 

Optically linear dimming 
curve 

Square 

Square law dimming curve 

Inv Sq 

Inverse square law 
dimming curve 

S-Curve

S-curve (fixture emulates
incandescent
lamp voltage linear RMS
dimming curve)

PWM Freq 

600-2400Hz

 LED PWM frequency 
(Default = 1200 Hz) 

No Data 

Blackout 

If data connection is lost, 
fixture will blackout    

Hold 

If data connection is lost, 
fixture holds latest received 
data value at all channels   

Содержание Martin ELP WW

Страница 1: ...ELP WW LED Profile User Manual...

Страница 2: ...nability to use or reliance on the information contained in this manual Martin HARMAN and all other trademarks in this document pertaining to services or products by Martin Professional or its affilia...

Страница 3: ...ssion 13 Connecting the DMX data link 13 Fixture setup 14 Using the control menus 14 Control panel display 14 Fast focus mode 14 Setting the DMX address 14 Setting DMX personality 15 Other fixture set...

Страница 4: ...fire hazard or a risk of eye injury if the safety precautions below are not followed Respect all locally applicable laws codes and regulations when installing operating applying power to or servicing...

Страница 5: ...of nine 9 ELP PROFILE fixtures in total to power in a chain at 200 240 V Before using the fixture check that all power distribution equipment and cables are in perfect condition are rated for the curr...

Страница 6: ...ar the weight of all the devices they are intended to support plus an adequate safety margin and that they conform to local building and safety regulations If the fixture is installed in a location wh...

Страница 7: ...0 scenes The fixture is supplied with this user manual a 1 5 m 4 9 ft power cable ready for a local power plug not included and a yoke for attachment of suitable user supplied rigging clamps Before us...

Страница 8: ...ing thumbscrew Fine focus adjustment wheel 6 Beam shaping shutter handles 7 Gobo accessory gate with sliding cover 8 Mounting bracket yoke 9 Tilt locking knob 10 Heatsink vent 11 Safety cable attachme...

Страница 9: ...posed to sunlight or another strong light source from any angle even for a few seconds Important Do not point the output from other lighting fixtures at the fixture as powerful light can damage the di...

Страница 10: ...ecuring with a safety cable Secure the fixture with a safety cable or other suitable secondary attachment that is approved for the weight of the fixture so that the safety cable will hold the fixture...

Страница 11: ...the front of the lens assembly with one hand so that it cannot fall out 2 Remove the thumbscrews 2 and 3 from the top and bottom of the lens tube The top screw also has the focusing wheel attached 3...

Страница 12: ...cted from power If you install a power plug on the supplied power cable install a grounding type earthed plug with integral cable grip that is suitable for your local mains voltage and is rated minimu...

Страница 13: ...meters 1000 ft Heavier gauge cable and or a DMX buffer is recommended for longer runs The pin out on all connectors is pin 1 shield pin 2 cold pin 3 hot Pins 4 and 5 in the XLR connectors are not used...

Страница 14: ...completely press and hold the MENU button Control panel display See photo on right When you power the fixture on it resets and then shows the following data in the control panel display Name of produc...

Страница 15: ...e described in the section DMX protocol on page 24 To set the DMX personality 1 Enter the control menu and select DMX SETUP Press ENTER 2 Select DMX MODE and press ENTER 3 Use the UP and DOWN buttons...

Страница 16: ...eed necessary to keep the fixture within its normal operating temperature range Light output is not reduced unless full fan speed is not enough to keep the fixture within its safe operating temperatur...

Страница 17: ...the UP and DOWN buttons to select a value from 0 to 255 Press MENU to go back up and select a different function to control Calibration From the SERVICE menu you can select CALIBRATION This menu allow...

Страница 18: ...er UID This process can take some time depending on the number of devices on the link Getting status and setting options by RDM The status and options listed in the table below can be read and set by...

Страница 19: ...Martin ELP WW User Manual 19 DMX_START_ADDRESS DEVICE_HOURS IDENTIFY_DEVICE LAST_STATE DIMMER_CURVE...

Страница 20: ...see drawings below Loosen the thumbscrews A and B on the top and bottom of the lens tube slightly then turn the focus wheel C to slide the lens in or out of the tube Tighten the thumbscrews A and B a...

Страница 21: ...t spill and retain the goboholder in the fixture To install a goboholder or iris 1 Allow the fixture to cool See drawing below Loosen but do not remove the two thumbscrews arrowed at the sides of the...

Страница 22: ...s cleaning requirements in your particular situation If in doubt consult your Martin dealer about a suitable maintenance schedule Use gentle pressure only when cleaning and work in a clean well lit ar...

Страница 23: ...mpanion 1 Apply power to the fixture s and allow to boot Connect the Martin Companion Cable hardware interface to your PC and to the fixture s DMX IN connector or to the DMX link All ELP fixtures that...

Страница 24: ...ion 1CH 2CH 4CH 1 1 1 0 255 Dimmer 0 100 2 0 255 Dimmer Fine 3 Shutter 000 031 Blackout 032 063 Open 064 095 Strobe Slow Fast 096 127 Open 128 159 Pulse effect in sequences 160 191 Open 192 223 Random...

Страница 25: ...512 available DMX Mode 1CH 2CH 4CH DMX control mode Personality Stand Alone Off Master Fixture acts as master in master client operation DMX RDM signal will override master client operation Client Fix...

Страница 26: ...key press Rotation Normal Display orientation normal Rotate 180 Display orientation rotated 180 Intensity 10 100 Set display intensity in default 100 Temp Unit C All temperature readouts in C F All t...

Страница 27: ...l to see values being received on each DMX channel Manual Ctrl Reset No Yes Reset fixture Dimmer Dimmer Fine Shutter Dimmer Fade 0 255 Manual control of all 4 channels Service Calibration Dimmer 0 100...

Страница 28: ...DMX control Fault in the DMX network due to wiring problem connector or cable damaged or incorrect DMX addressing or potential interference from proximity to a high voltage installation Check if the...

Страница 29: ...A RDM compliance ANSI ESTA E1 20 Transceiver Opto isolated RS 485 Optics Light source 91 x 3 W warm white LEDs Color Temperature 3000 K Lens tube options 19 26 36 50 15 30 zoom 25 50 zoom Minimum LED...

Страница 30: ...ts made at nominal voltage with all LEDs at full intensity Allow for a deviation of 10 Thermal Cooling Forced air temperature regulated low noise Maximum ambient temperature Ta max 40 C 104 F Minimum...

Страница 31: ...RDM 5 5 Splitter P N 90758150 Martin Companion Cable USB DMX Interface P N 91616091 Martin Companion software suite Free download from www martin com Ordering Information Fixtures without lens tubes M...

Страница 32: ...or a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment ge...

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...www martin com...

Отзывы: