12
Martin® ELP WW User Manual
AC power
Warning!
Read ‘Safety information’ on page 4 before installing the fixture.
Warning! The 18 AWG / 0.75 mm
2
mains power input cable supplied with the
fixture is rated 6 A and can supply only one fixture with mains power. Do not
connect any device to the fixture’s MAINS OUT socket when using this input
cable. If you want to connect other fixtures to the MAINS OUT socket, see
‘Linking fixtures to power in a chain’ on page 12.
For protection from electric shock, the fixture must be grounded (earthed). The power
distribution circuit must be equipped with a fuse or circuit breaker and ground-fault
(earth-fault) protection.
Important!
Do not use an external dimming system to supply power to the fixture, as this may
cause damage to the fixture that is not covered by the product warranty.
The fixture has an auto-ranging power supply that accepts AC mains power at 100-240 V at 50/60
Hz. Do not apply AC mains power at any other voltage or frequency to the fixture.
The fixture can be hard-wired to a building electrical installation if you want to install it
permanently, or a power plug (not supplied) that is suitable for the local power outlets can be
installed on the power cable. Socket outlets or external power switches used to supply the fixture
with power must be located near the fixture and easily accessible so that the fixture can easily be
disconnected from power.
If you install a power plug on the supplied power cable, install a grounding type (earthed) plug with
integral cable grip that is suitable for your local mains voltage and is rated minimum 6 A. Follow
the plug manufacturer’s instructions and connect the wires in the power cable as shown in this
table:
Live or L
Neutral or N
Earth, Ground or
US system
Black White
Green
EU system
Brown Blue
Yellow/green
Linking fixtures to power in a chain
The mains power input cable supplied with the fixture is rated 6 A and can safely supply power to
one fixture only.
If you want to use the MAINS OUT socket on the fixture to link power to another fixture in a daisy-
chain, you must first replace the supplied power input cable with one of the 16 amp rated 12 AWG
/ 2.5 mm
2
power input cables available as optional accessories from Martin (see ‘Accessories’ on
page 30). If you install a power plug on a 12 AWG / 2.5 mm
2
power input cable, install a grounding
type (earthed) plug with integral cable grip that is rated minimum 16 A, 250 V.
To link fixtures to power in a daisy-chain, use the 16 amp rated 12 AWG / 2.5 mm
2
power relay
cables available from Martin (see ‘Accessories’ on page 30) to link fixtures’ MAINS OUT sockets to
MAINS IN sockets. Using the 16 amp rated cables available as accessories from Martin, you can
link:
•
Maximum four (4) ELP PROFILE fixtures in total at 100-120 V, or
•
Maximum nine (9) ELP PROFILE fixtures in total at 200-240 V.
Do not exceed these limits.
If you create custom power relay cables, use only the Neutrik PowerCON TRUE1 connectors listed
under ‘Accessories’ on page 30.