Service and display messages
35
Error messages
Error messages indicate that there is a serious problem. The Atomic 3000 LED communicates errors as
follows:
• Error messages flash in the display.
• If more than one error is detected, the fixture flashes all errors three times each.
• Errors are shown in the display regardless of display status: they override an inactive display and any
other information that the display might be showing.
• If an error is present, the status LED flashes red.
The possible error messages are listed in Table 8 below
:
Short code
Long message and explanation
BETC
BEAM TMP CUTOFF
Beam PCB temperature too high. Beam shut down, fans set to max. Error message is cleared
when fixture is reset.
COLD
FIXTURE COLD
PCBs are below -20° C (-4° F). Effect operation may be abnormal or disabled due to cold.
FAN
BASE FAN 1 ERR
Base cooling fan 1 has stopped running. Error message is cleared when fixture is reset.
FAN
BASE FAN 2 ERR
Base cooling fan 2 has stopped running. Error message is cleared when fixture is reset.
FAN
BASE FAN 3 ERR
Base cooling fan 3 has stopped running. Error message is cleared when fixture is reset.
FAN
BASE FAN 4 ERR
Base cooling fan 4 has stopped running. Error message is cleared when fixture is reset.
PUTC
PSU TEMP CUT OFF
PSU temperature too high. Thermal cutoff activated. Light output is shut down, fans set to max.
Error message is cleared when fixture is reset.
PUTE
PSU TEMP SEN ERR
Error in PSU temperature sensor detected. Thermal cutoff activated. Light output is shut down.
Error message is cleared when sensor error is no longer detected.
SLER
SAFETY LOOP
Lamp safety loop circuit activated. Lamp temperature circuit breaker has cut lamp power. Circuit
breaker resets automatically after lamp temperature has returned to normal operating range.
UITC
UI TEMP CUT OFF
User interface PCB temperature too high. Thermal cutoff activated. Light output is shut down,
fans set to max. Error message is cleared when fixture is reset.
UITE
UI TEMP SEN ERR
Error in user interface temperature sensor detected. Thermal cutoff activated. Light output is
shut down. Error message is cleared when sensor error is no longer detected.
Table 8: Error messages