Warning! The Atomic 3000 LED has two safety cable attachment points (see Figure 1 on page 7).
Secure the Atomic Colors scroller against falling with a safety cable passed through the attachment
point on the right when viewed from the back of the fixture. Use the other attachment point for the
safety cable that secures the fixture.
Warning! Do not operate the Atomic 3000 LED with an Atomic Colors scroller in front of it unless the
scroller is correctly connected to the fixture. If an Atomic Colors is fastened to the front of an
Atomic 3000 LED but the power connection from the fixture to the scroller is interrupted or faulty,
the light and heat output from the Atomic 3000 LED can very quickly melt the gel in the scroller.
Do not use a Martin™ MP-2 or MP-8 external power supply unit to supply power to an Atomic Colors
scroller when you install the scroller on an Atomic 3000 LED.
Do not connect more than one Atomic Colors scroller to one Atomic 3000 LED. If you connect an
Atomic Colors to an Atomic 3000 LED, do not connect anything to the 4-pin XLR power and data
output connector of the Atomic Colors.
Every time you install an Atomic Colors scroller on an Atomic 3000 LED and any time you are in
doubt about whether there is a correct power connection between the two devices, check
INFO
→
COLOR SCROLLER
→
CONNECTED
in the Atomic 3000 LED’s control panel. Only operate the fixture
if the status here reads
YES
. If the status reads
NO
, check and rectify all connection problems
before you operate the fixture.
If you install an Atomic Colors scroller on an Atomic 3000 LED, select the following options in the
Atomic Colors control panel:
• Set Fan Speed
Fn
to maximum:
Fn4
.
• Set Light-Activated Fan
LF
to fans constantly on:
LF0
.
• Set the Gel Saver mode
GL
to active:
GL1
.
To install an Atomic Colors scroller on the Atomic 3000 LED fixture:
1. See the Atomic Colors user manual for full installation details. This manual is available for download
from the Martin™ website at www.martin.com.
2. Fasten the Atomic Colors in position on the fixture following the physical installation instructions in the
Atomic Colors user manual. Do not over-tighten the retaining screws when fastening the Atomic Colors
to the fixture.
3. See Figure 7. Connect the Atomic Colors to the 4-pin XLR connector (arrowed) on the back of the fixture
to control the scroller and supply it with power. Do not use an external power supply with the Atomic
Colors, as this will prevent the Atomic 3000 LED from sensing that the Atomic Colors is present and
could cause damage to the colored gels. Use only the Atomic Colors scroller cable supplied by Martin™
to connect an Atomic Colors to an Atomic 3000 LED. Do not use a cable that is longer than 5 m (16.4 ft.)