Service and display messages
The Atomic 3000 LED gives service and maintenance information by displaying a large 3- or 4-character
short code and a smaller full-text message in the fixture’s display. The short code is visible at a distance,
allowing easier reading if the fixture is overhead in a rig, for example, while the full-text message gives more
detailed information.
Warning messages
Warning messages indicate that either:
• problems might appear in the future if no action is taken, or
• the user needs to pay special attention to a function or procedure when working with the fixture.
The Atomic 3000 LED communicates warnings as follows:
• Warning codes are shown continuously in the display and disappear when the user reacts to the warning.
• If more than one warning is detected, all warnings are displayed in sequence.
• If the display is inactive, the fixture’s status LED (see Figure 8 on page 16) flashes orange to indicate that
there is a warning. Activating the display will show the warning.
The possible warning messages are listed in Table 7 below
:
* High temperature warnings are canceled as soon as temperature returns to normal. If temperature
reaches cutoff level, the warning is replaced by a cutoff error message.
Short code
Long message and explanation
BANK
BANK NO ACCESS
Error unpacking firmware bank during/after software upload. Fixture will continue to operate on
existing firmware. Warning message is cleared by a successful software upload or at the next
power off/on cycle.
BETW
BEAM TEMP HIGH
Beam PCB sensor detects that normal operating temperature is exceeded.*
PUTW
PSU TEMP HIGH
Power supply unit PCB sensor detects that normal operating temperature is exceeded.*
SL W
SAFETY LOOP
A safety loop error occurred but is no longer active. Warning message is cleared at the next
power off/on cycle.
UITW
UI TEMP HIGH
Control panel PCB sensor detects that normal operating temperature is exceeded.*
Table 7: Warning messages