background image

Harman®  •  Accentra52i-TC Installation Manual_R8  •  2017 -___  •  01/19

4

3-90-00584i

A. Appliance Certification

B. Glass Specifications

This appliance is equipped with 5mm ceramic glass. 

Replace glass only with 5mm ceramic glass. Please contact 

your dealer for replacement glass.

C. Mobile Home Approved

This appliance is approved for mobile home installations 

when not installed in a sleeping room and when an outside 

combustion air inlet is provided. 

The structural integrity of the mobile home floor, ceiling, and 

walls must be maintained. The appliance must be properly 

grounded to the frame of the mobile home using a minimum 

of 8 AWG copper solid or stranded, insulated or bare wire 

or equivalent

  and  use  only  listed  pellet  vent,  Class  “PL” 

connector pipe.

A  Harman®  Outside Air  Kit  must  be  installed  in  a  mobile 

home installation.

NOTE: 

This installation must conform with local codes. 

In the absence of local codes you must comply with the 

ASTM E1509-12, ULC-S628-93

 &

 (UM) 84-HUD 

MODEL:

Accentra52i-TC Pellet Insert

LABORATORY:

OMNI Test Laboratories, Inc

REPORT NO.

0135PN031E

TYPE:

Pellet Fueled Insert/Supplementary 

For Residential Use

STANDARD(s):

ASTM E 2779-10, ASTM E 2515-11, 

ASTM E 1509-12, ULC-S628-93

D. BTU & Efficiency Specifications

Product Specific and Important Safety Information 

The 

Accentra52i-TC Pellet Insert is certified 

to comply with 2020 EPA particulate emission 

standards.

T H E   S T R U C T U R A L   I N T E G R I T Y   O F   T H E 

MANUFACTURED HOME FLOOR, WALL, AND 

CEILING/ROOF MUST BE MAINTAINED.

CAUTION

!

DO NOT INSTALL IN SLEEPING ROOM.

WARNING

!

*  Weighted  average  LHV  efficiency  using  data  collected 

during EPA emissions test.

**Weighted  average  HHV  efficiency  using  data  collected 

during EPA emissions test.

***A range of BTU outputs based on EPA Default Efficiency 

and the burn rates from the low and high EPA tests.

****Based on the maximum feed rate per hour multiplied by 

approximately 8600 BTU’s which is the average BTU’s from 

a pound of pellets.

This wood heater has a manufacturer-set minimum low burn 

rate that must not be altered. It is against federal regulations 

to alter this setting or otherwise operate this wood heater 

in a manner inconsistent with operating instructions in this 

manual.
This wood heater needs periodic inspection and repair for 

proper operation. It is against federal regulations to operate 

this wood heater in a manner inconsistent with operating 

instructions in this manual.

EPA Certification Number:

84-17

EPA Certified Emissions:

1.1 g/hr

*LHV Tested Efficiency:

81.3%

**HHV Tested Efficiency:

76.1%

***EPA BTU Output:

7,400 - 39,700

****BTU Input

11,200 - 50,300

Vent Size:

4 Inch

Hopper Capacity:

64.5 lbs

Fuel

Wood Pellet

Note: 

This installation must conform with local codes. 

In the absence of local codes you must comply with the 

ASTM E 1509-2012, ULC S628-93, (UM) 84-HUD 

Note: 

Hearth & Home Technologies, manufacturer of this 

appliance, reserves the right to alter its products, their 

specifications and/or price without notice.

Harman

®

  is  a  registered  trademark  of  Hearth  &  Home 

Technologies.

Note: 

Some generator or battery back-up systems may 

not be compatible with the micro-processor electronics 

on this appliance. Please consult the power supply 

manufacturer for compatible systems.

Содержание Accentra52i-TC

Страница 1: ...rnal part starts to glow you are overfiring Reduce feed rate Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire W...

Страница 2: ...F Combustible Materials Specification 5 G Electrical Codes 5 H California 5 2 Getting Started A Design and Installation Considerations 6 B Tools and Supplies Needed 7 C Inspect Appliance and Component...

Страница 3: ...___________________________ Electrical Section 1 120 VAC unswitched power provided to the appliance ________________________________ Check outlet with multi meter for proper voltage 115 120 VAC ______...

Страница 4: ...D CAUTION DO NOT INSTALL IN SLEEPING ROOM WARNING Weighted average LHV efficiency using data collected during EPA emissions test Weighted average HHV efficiency using data collected during EPA emissio...

Страница 5: ...s any responsibility for and the warranty and agency listing will be voided by the below actions DO NOT Install or operate damaged appliance Modify appliance Install other than as instructed by Hearth...

Страница 6: ...NOT recommended Not the highest point of the roof Wind loading possible Multi level Roofs Windward Leeward Recommended Outside Air Intake on windward side NOT recommended Outside Air Intake on leeward...

Страница 7: ...e glass Read all of the instructions before starting the installation Follow these instructions carefully during the installation to ensure maximum safety and benefit Hearth Home Technologies disclaim...

Страница 8: ...nsions Use for reference only Figure 3 1 32 1 8 41 13 16 31 5 16 25 9 16 22 20 24 19 9 16 29 15 16 13 16 15 9 16 14 3 8 12 3 4 Unit 1 90 574240 Hopper Capacity 64 5 lbs 29 25 kg Unit 1 90 574220 Hoppe...

Страница 9: ...o Combustibles Floor Protection Floor protection must be used from hearth opening to 6 152mm in front of door glass and 6 152mm to each side of the stove body OR 8 203mm to sides to protect combustibl...

Страница 10: ...ove body spaces The chimney top must be capped to prevent rain and or snow from entering the chimney See Figure 4 8 for information on the optional Harman Adjustable Stainless Steel Intake Extension T...

Страница 11: ...plate and it is recommended that Kaowoll mineral wool or an equivalent non combustible insulation be placed on top of the sealed area to reduce the possibility of condensation Insulation alone should...

Страница 12: ...eal the damper area around the chimney liner with fiberglass batting Note If the Harman Accentra52i TC Pellet Insert is installed into a factory built wood burning fireplace this label Harman part 3 9...

Страница 13: ...throughs and terminations are used Note Flex pipe is not approved these types of installation Detailed installation instructions are included with the Zero Clearance Cabinet These same installation in...

Страница 14: ...ng will require more frequent cleaning It is the responsibility of the installer to make sure the entire flue configuration is accessible for cleaning 4 stainless steel flex vent piping is only allowe...

Страница 15: ...blower every few seconds to clear exhaust until the fire is out Note The UPS provides safe shut down only It is not intended for continued operation Your appliance will recognize when power is restor...

Страница 16: ...st part of the roof This minimizes the effects of wind loading Locate termination cap away from trees adjacent structures uneven roof lines and other obstructions Minimize the use of chimney offsets C...

Страница 17: ...own and Power Failure To reduce the probability of back drafting or burn back in the pellet burning appliance during power failure or shut down conditions the stove must be able to draft naturally wit...

Страница 18: ...sert operates with a positive vent pressure we specify that the joints also be sealed with silicone Where passing through an exterior wall or roof be sure to use the appropriate pass through device pr...

Страница 19: ...each end with an NEC approved grounding device 5 Refer to Clearances to Combustibles and Floor Protection section of this manual for listings to combustibles 6 Use silicone to create an effective vap...

Страница 20: ...during the installation to ensure maximum safety and benefit Inspect appliance and components for damage Damaged parts may impair safe operation Do NOT install damaged components Do NOT install incomp...

Страница 21: ...inge pins See Figure 5 1 2 Remove the ash pan 3 Remove the 4 internal pieces of cast iron Figure 5 2 See Figure 5 3 and Figure 5 4 for removal instructions Figure 5 2 Center Medallion Flame Guide Heat...

Страница 22: ...ifting it upward about 1 2 inch and move the bottom edge front until it sits flat on the firebox bottom 3 Rotate the right side of the heat exchanger toward the door opening until you are able to remo...

Страница 23: ...b assembly base is a round plate which allows it to swivel to allow the flue pipe to exit the mounting frame in other positions rather than straight up Figure 5 10 Figure 5 7 Install 20 x Studs Instal...

Страница 24: ...Connection Installation Note If the room sensor is connected as a return air sensor the wire should be connected long enough to allow this but not too long that it would get tangled or pinched anywhe...

Страница 25: ...he bottom of the top hinge behind the large washer on the center bolt Figure 5 18 Figure 5 18 Slide top hinge behind washer Install the top bolt and washer on the top hinge Finger tighten all 3 bolts...

Страница 26: ...from the control to the rear inside of the body Make sure there are no worn or frayed areas Do not allow pellets or sawdust to build up on the hopper lip Figure 24 Inspect the hopper lid gasket for da...

Страница 27: ...e house CAUTION F Firebox Draft and Combustion Fan RPM These units are pre tested at the factory with exactly 120 VAC 60 Hz They are checked and adjusted for firebox tightness gasket leakage motor ope...

Страница 28: ...USE FIRE USE ONLY APPROVED FUELS AND OPERATION GUIDELINES WARNING THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED CAUTION THE STOVE IS HOT WHILE IN OPERATION...

Страница 29: ...MP 250 VAC 10 AMP YELLOW SKY BLUE BROWN SKY BLUE BLACK 11 LINE FILTER INSIDE BURNPOT IGNITER ELEMENT COMBUSTION MOTOR FEEDER AUGER MOTOR 3 1 2 5 4 8 7 6 SKY BLUE PLUGGED SKY BLUE SKY BLUE BLUE EMPTY Y...

Страница 30: ...___ 01 19 30 3 90 00584i 352 Mountain House Road Halifax PA 17032 www harmanstoves com Please contact your Harman dealer with any questions or concerns For the location of your nearest Harman dealer p...