After the installation is completed, but before the first fire is lit, check and record the high and low 

draft readings.

Press the icon a second time, the combustion fan will go 

to “Maximum” (as set in the 

Authorized Dealer Only

 area 

under the combustion fan icon)

The “Maximum” is factory set at 2900 RPM. Allow the RPM 

to stabilize and record the firebox draft Maximum.

 

Before Install: __________ IWC

 

After Install: __________ IWC

(Firebox Draft and Combustion Fan RPM Cont.)

Press the icon a third time, the combustion fan will go to 

“Minimum”  (as  set  in  the 

Authorized Dealer Only

 area 

under the combustion fan icon) allow the RPM to stabilize 

and record the firebox draft minimum.

 

Before Install: __________ IWC

 

After Install: __________ IWC

Cold Stove Draft:

2500 RPM 

Low -.20 and -.25

2900 RPM 

High -.45 and -.50

Leaving the test screen will end any tests in progress and 

goes back to whatever mode of operation it was set to on 

the home screen.

If the unit is not adjusted properly, it does not cause a safety 

concern. If the unit is adjusted too high, only efficiency is lost. 

If the unit is adjusted too low, the low draft pressure switch 

will not allow the feed motor or the igniter to operate.

Figure 5.25

Silicone Draft Meter Port

The Draft Test Port can be accessed from inside the left hand 

side door just below the power supply plug.

•  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE 

SERVICING ANOTHER APPLIANCE.

•  DO  NOT  CONNECT  TO ANY AIR  DISTRIBUTION 

DUCT OR SYSTEM.

May allow flue gases to enter the house

CAUTION

!

F. Firebox Draft and Combustion Fan RPM

These units are pre-tested at the factory with exactly 120 VAC, 

60 Hz. They are checked and adjusted for firebox tightness, 

gasket leakage, motor operation and igniter operation. The 

Accentra52i-TC is then factory set at a mid-point adjustment 

and in most cases will not need any adjustments.

Check and record the firebox draft before installing venting 

and after venting is installed 

(before starting fire)

.

There is a silicone draft meter port located behind the left 

hand door at the power supply plug. Install the magnahelic 

meter 

(capable of at least .5” of water column) 

Figure 5.25.

Considerations for successful draft include:

•  Negative pressure in the firebox
•  Location of appliance and chimney

To measure the draft or negative pressure on your appliance 

use a magnahelic or a digital pressure gauge capable of 

reading 0 - 1 inches of water column (W.C.).

 

The appliance should be running on high for at least 15 

minutes for the test.
With the stove running on high you should have a negative 

pressure equal to or greater than the number given in the 

chart below. If you have a lower reading than you find on the 

chart, your appliance does not have adequate draft to burn 

the fuel properly.

Plug unit into a 120 VAC, 60 Hz outlet.
Go to the “Home Screen”, the power icon should be gray. 

Press menu, on the first menu press “test”.

The test screen has 4 component test modes. The second 

icon is for the combustion fan test.

One press of the icon turns the combustion fan to full line 

voltage. 

(Note: During this test , the combustion fan will 

not achieve its top RPM of 3200 due to the density of the 

ambient air.)

 All RPM displays could vary +/- 50 from that 

of the set RPM’s. Allow several minutes for the fan motor to 

warm up.

Содержание Accentra52i-TC

Страница 1: ...rnal part starts to glow you are overfiring Reduce feed rate Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire W...

Страница 2: ...F Combustible Materials Specification 5 G Electrical Codes 5 H California 5 2 Getting Started A Design and Installation Considerations 6 B Tools and Supplies Needed 7 C Inspect Appliance and Component...

Страница 3: ...___________________________ Electrical Section 1 120 VAC unswitched power provided to the appliance ________________________________ Check outlet with multi meter for proper voltage 115 120 VAC ______...

Страница 4: ...D CAUTION DO NOT INSTALL IN SLEEPING ROOM WARNING Weighted average LHV efficiency using data collected during EPA emissions test Weighted average HHV efficiency using data collected during EPA emissio...

Страница 5: ...s any responsibility for and the warranty and agency listing will be voided by the below actions DO NOT Install or operate damaged appliance Modify appliance Install other than as instructed by Hearth...

Страница 6: ...NOT recommended Not the highest point of the roof Wind loading possible Multi level Roofs Windward Leeward Recommended Outside Air Intake on windward side NOT recommended Outside Air Intake on leeward...

Страница 7: ...e glass Read all of the instructions before starting the installation Follow these instructions carefully during the installation to ensure maximum safety and benefit Hearth Home Technologies disclaim...

Страница 8: ...nsions Use for reference only Figure 3 1 32 1 8 41 13 16 31 5 16 25 9 16 22 20 24 19 9 16 29 15 16 13 16 15 9 16 14 3 8 12 3 4 Unit 1 90 574240 Hopper Capacity 64 5 lbs 29 25 kg Unit 1 90 574220 Hoppe...

Страница 9: ...o Combustibles Floor Protection Floor protection must be used from hearth opening to 6 152mm in front of door glass and 6 152mm to each side of the stove body OR 8 203mm to sides to protect combustibl...

Страница 10: ...ove body spaces The chimney top must be capped to prevent rain and or snow from entering the chimney See Figure 4 8 for information on the optional Harman Adjustable Stainless Steel Intake Extension T...

Страница 11: ...plate and it is recommended that Kaowoll mineral wool or an equivalent non combustible insulation be placed on top of the sealed area to reduce the possibility of condensation Insulation alone should...

Страница 12: ...eal the damper area around the chimney liner with fiberglass batting Note If the Harman Accentra52i TC Pellet Insert is installed into a factory built wood burning fireplace this label Harman part 3 9...

Страница 13: ...throughs and terminations are used Note Flex pipe is not approved these types of installation Detailed installation instructions are included with the Zero Clearance Cabinet These same installation in...

Страница 14: ...ng will require more frequent cleaning It is the responsibility of the installer to make sure the entire flue configuration is accessible for cleaning 4 stainless steel flex vent piping is only allowe...

Страница 15: ...blower every few seconds to clear exhaust until the fire is out Note The UPS provides safe shut down only It is not intended for continued operation Your appliance will recognize when power is restor...

Страница 16: ...st part of the roof This minimizes the effects of wind loading Locate termination cap away from trees adjacent structures uneven roof lines and other obstructions Minimize the use of chimney offsets C...

Страница 17: ...own and Power Failure To reduce the probability of back drafting or burn back in the pellet burning appliance during power failure or shut down conditions the stove must be able to draft naturally wit...

Страница 18: ...sert operates with a positive vent pressure we specify that the joints also be sealed with silicone Where passing through an exterior wall or roof be sure to use the appropriate pass through device pr...

Страница 19: ...each end with an NEC approved grounding device 5 Refer to Clearances to Combustibles and Floor Protection section of this manual for listings to combustibles 6 Use silicone to create an effective vap...

Страница 20: ...during the installation to ensure maximum safety and benefit Inspect appliance and components for damage Damaged parts may impair safe operation Do NOT install damaged components Do NOT install incomp...

Страница 21: ...inge pins See Figure 5 1 2 Remove the ash pan 3 Remove the 4 internal pieces of cast iron Figure 5 2 See Figure 5 3 and Figure 5 4 for removal instructions Figure 5 2 Center Medallion Flame Guide Heat...

Страница 22: ...ifting it upward about 1 2 inch and move the bottom edge front until it sits flat on the firebox bottom 3 Rotate the right side of the heat exchanger toward the door opening until you are able to remo...

Страница 23: ...b assembly base is a round plate which allows it to swivel to allow the flue pipe to exit the mounting frame in other positions rather than straight up Figure 5 10 Figure 5 7 Install 20 x Studs Instal...

Страница 24: ...Connection Installation Note If the room sensor is connected as a return air sensor the wire should be connected long enough to allow this but not too long that it would get tangled or pinched anywhe...

Страница 25: ...he bottom of the top hinge behind the large washer on the center bolt Figure 5 18 Figure 5 18 Slide top hinge behind washer Install the top bolt and washer on the top hinge Finger tighten all 3 bolts...

Страница 26: ...from the control to the rear inside of the body Make sure there are no worn or frayed areas Do not allow pellets or sawdust to build up on the hopper lip Figure 24 Inspect the hopper lid gasket for da...

Страница 27: ...e house CAUTION F Firebox Draft and Combustion Fan RPM These units are pre tested at the factory with exactly 120 VAC 60 Hz They are checked and adjusted for firebox tightness gasket leakage motor ope...

Страница 28: ...USE FIRE USE ONLY APPROVED FUELS AND OPERATION GUIDELINES WARNING THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED CAUTION THE STOVE IS HOT WHILE IN OPERATION...

Страница 29: ...MP 250 VAC 10 AMP YELLOW SKY BLUE BROWN SKY BLUE BLACK 11 LINE FILTER INSIDE BURNPOT IGNITER ELEMENT COMBUSTION MOTOR FEEDER AUGER MOTOR 3 1 2 5 4 8 7 6 SKY BLUE PLUGGED SKY BLUE SKY BLUE BLUE EMPTY Y...

Страница 30: ...___ 01 19 30 3 90 00584i 352 Mountain House Road Halifax PA 17032 www harmanstoves com Please contact your Harman dealer with any questions or concerns For the location of your nearest Harman dealer p...

Отзывы: