The screen shows the individual load sensors in dwell mode. Using the right+ left button, move from Sensor to
Sensor. The pass/fail test requires 15-30 seconds to complete testing.
IT Dwell – Jbox1
Channel x (x/5)
RAW
Waversaver Results OK
OK
Variation 0.45
0.00
mV/V
0.0219
Weight
-0.378605
RTZ
PASS
Integrated Technician Test for the HI 6600 over Communications
For Integrated Technician testing and data run over communications, there are two different tests the user can run:
•
The normal Integrated Technician test
•
The Reduced Voltage Integrated Technician test, which requires the new HI 6020IT summing card.
NOTE:
The HI 6600 can use one HI 6020IT summing cards, with up to 4 load cells.
Once the test has been run, the unit will have the data collected during the test available. This data includes:
The number of load cells specified for each junction box.
Weight readings for each load cell and the junction box reference weight.
MV/V for each load cell and the junction box reference weight.
Raw variation for each load cell and the junction box reference weight.
WAVERSAVER® variation for each load cell and the junction box reference weight.
Raw variation results (pass/fail) for each load cell and junction box reference weight.
WAVERSAVER® variation results (pass/fail) for each load cell and junction box reference weight.
The Return to Zero (RTZ) results (pass/fail) for each load cell and reference weight as well as the combined
reading.
To run the test the user would need to know the parameter ID (a 32 bit hex value) for the two commands, Do IT Cmd and
Do IT Reduced (voltage) Cmd. These parameter IDs are:
16#00xx3197
Do IT Test Cmd
16#00xx3198
Do IT Reduced Cmd
The xx represents the Channel Number assigned to each Weight Processing Module. To run the test, the user would set
these parameters to a value of 1.
Once the IT Test has been run, the user can read each parameter ID they wish for the return value of that parameter. The
data will remain in the unit until the next time the IT test is run, which then would overwrite the previous data.
The parameter IDs are:
16#00xx3197
Do IT Test Cmd
16#00xx3197
Do IT Reduced Cmd
Содержание HI 6600-EIP
Страница 16: ...HI 6600 Series Modular Sensor System User Guide Page 16...
Страница 44: ...HI 6600 Series Modular Sensor System User Guide Page 44...
Страница 96: ...HI 6600 Series Modular Sensor System User Guide Page 96 General Troubleshooting Flow Chart Index...
Страница 97: ...HI 6600 Series Modular Sensor System User Guide Page 97 A ElectricalandMechanicalReview...
Страница 98: ...HI 6600 Series Modular Sensor System User Guide Page 98 A1 CheckingforUnstableComponentsinaWeighingSystem...
Страница 100: ...HI 6600 Series Modular Sensor System User Guide Page 100 B1 GuidelinestoVerifyElectricalInstallation...
Страница 101: ...HI 6600 Series Modular Sensor System User Guide Page 101 B2 GuidelinestoVerifyMechanicalInstallation...
Страница 102: ...HI 6600 Series Modular Sensor System User Guide Page 102 B3 VerifyConfiguration FilterSettingstoImproveStability...
Страница 103: ...HI 6600 Series Modular Sensor System User Guide Page 103 C IntegratedTechnicianandStabilityTestOverview...
Страница 104: ...HI 6600 Series Modular Sensor System User Guide Page 104 ENon ReturntoZero SystemwithITSummingCard...
Страница 106: ...HI 6600 Series Modular Sensor System User Guide Page 106 G Calibration Errors During Calibration...
Страница 107: ...HI 6600 Series Modular Sensor System User Guide Page 107 H Mechanical Installation...
Страница 108: ...HI 6600 Series Modular Sensor System User Guide Page 108 J Electrical Inspection...
Страница 109: ...HI 6600 Series Modular Sensor System User Guide Page 109 K InstallationCheckPoints...
Страница 110: ...HI 6600 Series Modular Sensor System User Guide Page 110 M WeightProcessor sOptionalFrontDisplayBlankorLocked...
Страница 128: ...HI 6600 Series Modular Sensor System User Guide Page 128...
Страница 130: ...HI 6600 Series Modular Sensor System User Guide Page 130 Image of HI 6600 Hardy Gateway Module II Diagram...
Страница 131: ...HI 6600 Series Modular Sensor System User Guide Page 131 Image of HI 6610 Weight Processing Module II Diagram...
Страница 132: ...HI 6600 Series Modular Sensor System User Guide Page 132 OptionalHI6110DisplayPanelMountingTemplate...