The changes to the calibration and read only security features are updated when you exit the security
submenu and return to the configuration menu; while changes to the display, keypad, or configuration
security settings are updated when the operator exits the configuration menu.
The factory default for the security menu is to disable all lock modes and to preset each of the security
passwords to 1234.
NOTE:
Once set, the security parameters can only be accessed via the Optional Front Panel display by
entering a preset password, or directly through the network connection. There is no way to bypass
the security password. We recommend you keep your passwords in a secure location.
The Display Lock
The Display Lock disables and blanks the Optional Front Panel display and disables the keypad. If the
ENTER button is pressed, a password dialog box is shown on the screen. If the correct password is entered
the display is unlocked and operator can view the weight data and use the MODE button to change the weight
between Gross and Net. If the ENTER button is pressed again the Display Lock parameter is reset to
ENABLED and the display blanked. This security setting blanks the front screen so the current weight
reading on the scale cannot be observed; and while the display is locked the Mode, Zero, Tare, and
Configuration buttons are disabled regardless of the keypad lock or configuration lock settings; as enabling
these buttons without the operator being able to read the Optional Front Panel display would lead to process
errors.
If the ENTER button is pressed the “Enter Password” page will appear on the display. At this level of security
the operator can enter one of three possible passwords for the display lock, the keypad lock, or the
configuration lock.
NOTE
If the keypad is locked, then the tare, zero, mode, and configuration buttons are disabled
Содержание HI 6600-EIP
Страница 16: ...HI 6600 Series Modular Sensor System User Guide Page 16...
Страница 44: ...HI 6600 Series Modular Sensor System User Guide Page 44...
Страница 96: ...HI 6600 Series Modular Sensor System User Guide Page 96 General Troubleshooting Flow Chart Index...
Страница 97: ...HI 6600 Series Modular Sensor System User Guide Page 97 A ElectricalandMechanicalReview...
Страница 98: ...HI 6600 Series Modular Sensor System User Guide Page 98 A1 CheckingforUnstableComponentsinaWeighingSystem...
Страница 100: ...HI 6600 Series Modular Sensor System User Guide Page 100 B1 GuidelinestoVerifyElectricalInstallation...
Страница 101: ...HI 6600 Series Modular Sensor System User Guide Page 101 B2 GuidelinestoVerifyMechanicalInstallation...
Страница 102: ...HI 6600 Series Modular Sensor System User Guide Page 102 B3 VerifyConfiguration FilterSettingstoImproveStability...
Страница 103: ...HI 6600 Series Modular Sensor System User Guide Page 103 C IntegratedTechnicianandStabilityTestOverview...
Страница 104: ...HI 6600 Series Modular Sensor System User Guide Page 104 ENon ReturntoZero SystemwithITSummingCard...
Страница 106: ...HI 6600 Series Modular Sensor System User Guide Page 106 G Calibration Errors During Calibration...
Страница 107: ...HI 6600 Series Modular Sensor System User Guide Page 107 H Mechanical Installation...
Страница 108: ...HI 6600 Series Modular Sensor System User Guide Page 108 J Electrical Inspection...
Страница 109: ...HI 6600 Series Modular Sensor System User Guide Page 109 K InstallationCheckPoints...
Страница 110: ...HI 6600 Series Modular Sensor System User Guide Page 110 M WeightProcessor sOptionalFrontDisplayBlankorLocked...
Страница 128: ...HI 6600 Series Modular Sensor System User Guide Page 128...
Страница 130: ...HI 6600 Series Modular Sensor System User Guide Page 130 Image of HI 6600 Hardy Gateway Module II Diagram...
Страница 131: ...HI 6600 Series Modular Sensor System User Guide Page 131 Image of HI 6610 Weight Processing Module II Diagram...
Страница 132: ...HI 6600 Series Modular Sensor System User Guide Page 132 OptionalHI6110DisplayPanelMountingTemplate...