5 - Operation
91
5.
Open the ChemLocker cover. The cleaning wand is located in the
holder (C).
6.
Pull out the hose from the reel.
7.
Turn the ball valve to position (A) to open.
8.
Wash the sprayer with the cleaning wand.
9.
When finished, disengage the pump and close the ball valve again
by turning it to position (B).
10.
Retract the hose and put the spray wand back in the holder (C).
ATTENTION! Do not let go of the hose. Gently restrict the roll-in of
the hose.
ATTENTION! If the sprayer is cleaned with a high pressure cleaner,
lubrication of the entire machine is recommended afterwards.
C: Rinsing When Main Tank Is Not Empty
This procedure is used to rinse the pump, operating unit, spray lines, etc. in case of stopping the spray job before the main
tank is empty (e.g. at the beginning of rain, etc.).
Cleaning of the liquid system:
1.
Turn Suction SmartValve to “Rinsing tank”. (Keep pressure SmartValve in “Spraying”-position).
÷
NOTE! The main ON/OFF function on the grip must be ON. Closing the main ON/OFF will transfer the rinse water back
to the main tank!
2.
Close agitation valve (no agitation).
3.
Turn off the CycloneFilter Boost Valve to avoid dilution of main tank content.
4.
Engage and set the pump to approximately 560 rpm and spray water from the rinsing tank into the field, until all boom
pipes and nozzles are flushed with clean water.
5.
Turn off the pump when rinsing is finished.
ATTENTION! It is advisable to increase the forward speed (double if possible) and reduce the spray pressure to 20 psi
(1.5 bar) when spraying diluted spray liquid in the field just sprayed.
ATTENTION! If a cleaning procedure is given on the chemical label, follow it closely.
Содержание COMMANDER 4500
Страница 2: ......
Страница 4: ......
Страница 10: ...Table of Contents 8...
Страница 12: ...1 Welcome 10...
Страница 48: ...3 Description 46...
Страница 96: ...5 Operation 94...
Страница 99: ...6 Maintenance 97 Lubrication and Oiling Plan Boom Width 80 100 10 10 10 C 500 C 50 C 50 10...
Страница 100: ...6 Maintenance 98 Lubrication and Oiling Plan Boom Width 120 10 C 500 C 50 10...
Страница 129: ...6 Maintenance 127 At the same time adjust the two stop bolts to align the boom sections...
Страница 142: ...6 Maintenance 140...
Страница 162: ...8 Technical Specifications 160...
Страница 168: ...Index 166...
Страница 169: ......