6 - Maintenance
101
Greasing the Pump
The pump is greased as follows:
•
Factory greased:
300 g grease into each lubrication point (A).
•
Normal operation:
Greasing every 50 hours with 30 grams of grease into each
lubrication point (A). See also “50 Hours Service - Greasing
the Pump” on page 106.
•
After disassembling the pump (diaphragm replacement, etc.):
Greasing with 200 grams of grease into each lubrication
point (A).
ATTENTION! In order to prevent excessive wear, it is important to
use a recommended lubricant (i.e. HARDI® part no. 28164600).
See “Recommended Lubricants” on page 95.
ATTENTION! The pump MUST be stopped during greasing!
Содержание COMMANDER 4500
Страница 2: ......
Страница 4: ......
Страница 10: ...Table of Contents 8...
Страница 12: ...1 Welcome 10...
Страница 48: ...3 Description 46...
Страница 96: ...5 Operation 94...
Страница 99: ...6 Maintenance 97 Lubrication and Oiling Plan Boom Width 80 100 10 10 10 C 500 C 50 C 50 10...
Страница 100: ...6 Maintenance 98 Lubrication and Oiling Plan Boom Width 120 10 C 500 C 50 10...
Страница 129: ...6 Maintenance 127 At the same time adjust the two stop bolts to align the boom sections...
Страница 142: ...6 Maintenance 140...
Страница 162: ...8 Technical Specifications 160...
Страница 168: ...Index 166...
Страница 169: ......