6 - Maintenance
100
Lubrication and Oiling Plan - PTO
The amount of grease to be applied is mentioned in grams (g). Test your grease gun to see how many grams it supplies, for
example after 5 strokes.
ATTENTION! The correct amount of grease applied at the intervals is important. Too little or too much grease will
shorten the lifetime of the PTO.
The grease points and amount of grease to be applied are shown in the pictures below together with the intervals.
Standard PTO for Tractor and Sprayer
Wide Angle PTO for Tractor, Standard PTO for Sprayer
Wide Angle PTO for Both Tractor and Sprayer
A-50
A-50
B-50
C-50
C-50
7UDFWRU
6SUD\HU
A-30
A-50
B-50
C-50
C-50
A-50
15g
6g
45g
6g
6g
15g
15g
15g
45g
30g
+
=
6SUD\HU
7UDFWRU
6g
15g
A-30
A-50
B-50
C-50
C-50
A-50
15g
6g
45g
6g
6g
15g
15g
30g
45g
15g
+
=
15g
30g
A-50
6SUD\HU
7UDFWRU