4-7-1 Exchange of main shaft timing belt
1. Remove bed cover B.
2. Let a disk reach 25 degrees.
3. Loosen two (2) pieces of screws indicated with red
arrows.
4. Remove six (6) pieces of screws, and then remove a left
cover.
5. Loosen a nut indicated with a red arrow by using a 7mm
spanner.
6. Rotate two (2) pieces of screws mounted on a tension plate
by approximate 180 degrees to loosen them.
Bed Cover B
Nut for tension adjustment
Tension Plate
Содержание HCR3-1502