188
E9 Trouble shooting
E9-1 Electricity doesn’t turn on
Trouble Factor Cause of trouble and measure
Page
Electricity
Mechanical
1. Did fuse blow?
doesn't turn on 1-1 If it did, replace it.
2. Check of defect on board.
2-1 Replace of LCD-CE board. E3-2
2-2 Replace of LCD unit. E3-2
2-3 Replace of CONT-R2 board E2-1
3. No problem in power supply?
3-1 Check and adjust the correct voltage.
E2-10
3-2 Try to replace power supply.
4. Check of Cable catching causes short-circuit.
4-1 Please insulate the cable after removing outer cover.
4-2 Replace of cable.
5. Confirm not getting power supply from same outlet with other embroidery
machine or other machines which contains motor.
5-1 Preferably only 1 embroidery machine should be connected with 1 outlet.
(Maximum 2-3machines)
Operator 1. Didn't press emergency switch?
1-1 Release lock.
Environment
1. Is electricity in receptacle?
1-1 Supply power.
( ) ----- Reference instruction book
Содержание HCR3-1502
Страница 1: ... Maintenance Manual for Embroidery Machine HCR3E SERIES Version 1 2 HappyJapan Inc ...
Страница 104: ...105 4 7 3 Adjustment of timing detecting unit 8 Finally put the cover back on ...
Страница 107: ...107 ...
Страница 172: ...172 E7 Electric system diagram E7 1 Pulse motor driver PMD wiring ...
Страница 173: ...173 E7 2 Pulse motor driver PMD setup ...
Страница 174: ...174 E7 3 Inverter wiring ...
Страница 175: ...175 E7 4 Electrical connection diagram ...
Страница 176: ...176 ...
Страница 177: ...177 ...
Страница 178: ...178 E7 5 List of electrical connection diagram ...
Страница 179: ...179 ...
Страница 180: ...180 E7 6 Explanation of function clrcuit board HCD8122 LCD CE MX Board Ass y ...
Страница 181: ...181 HCD8116 TP SW Circuit Board Ass y CN No Function CN1 Switch output LED input ...
Страница 182: ...182 HCR8121 CONT R2 Circuit Board Ass y ...
Страница 216: ...2018 9 HappyJapan Inc 9 5 TAITO 2 CHOME TAITO KU TOKYO JAPAN TEL 81 3 3834 0711 FAX 81 3 3835 8917 ...