Two post hydraulic lift HAPP 95
© 2013 HAPP Australia Pty Ltd
Version 9
Page
31
is not required, bridge(connect) these two wires to disable the connector.
Always put a 4 Amp inline fuse in the line to the limit switch and use 3 core earthed cable to
connect the limit switch. Inline fuse holders and limit switches are available from HAPP if
required.
11.2 Electrical wiring – AS3000
Power wiring will be according to the following Australian standard (AS3000), Electricians must
remove the top cover and verify ground , neutral and phase connections as well as limit switch
connection if required and connect wires according to the following specification.
Phases
Neutral
Earth
Australia, New Zealand (AS/NZS 3000:2007
3.8.3)
,
,
Connect to:
3/L2
5/L3
Motor
Chassis
Wiring of single phase power to motor control unit