background image

English _

31

 

!

USE AUDIO SER

VER

MAINTENANCE

Failover History Management

The failure history for the product can be input and managed.

1. 

On the Home screen, click 

<Maintenance> 

;

 

<Failover History Management>

.

 

~

If you click the [

Search

] button, you can search the results by date. 

 

~

Click the [

Delete

] button to delete the selected fault history.

 

~

Lists of Failure History: Shows the entire history of registered failures.

 

~

Register After inputting fixes and status of the failure history, they can be registered.

 

- Date: Only the today's date can be entered as an input, and the date cannot be changed. 

 

- Device Name: Enter the name of the device where a failure occurred. (Max. 20 characters)

 

- Status: Enter the failure status. (Max. 20 characters)

 

- Failover Contents: Enter the processing details. (Max. 70 characters)

 

- Registerer: Enter the name of the user. (Max. 20 characters)

 

~

Receive Lists:  The registered history of actions for malfunctions can be downloaded in the "csv" file 

format.  
As the history of actions for malfunction will be deleted when the product's system is 
initialized, please download it in advance. 

 

M

 

`

 Every input field must be filled in.

 

`

Special characters (’, ”) cannot be input in the input field. 

 

`

Locate a mouse pointer on a failure history item to see all the registered details.  

View Log

You can check logs generated in the product.
The log items are different for each product, and they are recorded when the log operation occurs. 

1. 

On the Home screen, click <

Maintenance

;

 <

View Log

>.

2. 

The action log history for the device is shown by item. 
The Log menu will appear on the View Log when its function is activated. 

3. 

If you click the [

Receive Logs

] button, a file can be downloaded in HTML format. 

Check HTML files via Google Chrome. 

 

~

As the log information will be deleted when the product's system is initialized, please download it in 
advance.

4. 

If you click the [

Delete Logs

] button, all logs displayed on the screen will be deleted.

5. 

The Output Unit, Auto Update, Update Period, and Scroll Mode can be set. 
If you activate <

Auto Update

>, logs will be displayed in accordance with the <

Update Cycle

>.

 

~

If you auto select <

Scroll Mode

>, the screen will be moved downward to show recent logs.

 

~

Press the [

Top/Bottom

] button to view the upper and lower logs. 

Содержание SPA-S1000

Страница 1: ...IP AUDIO SERVER User Manual SPA S1000...

Страница 2: ...n this document but no formal guarantee shall be provided Use of this document and the subsequent results shall be entirely on the user s own responsibility Hanwha Vision reserves the right to change...

Страница 3: ...mation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product CAUTI...

Страница 4: ...e it is exposed to direct sunlight near heating equipment or heavy cold area 22 Do not place this apparatus near conductive material 23 Do not attempt to service this apparatus yourself 24 Do not plac...

Страница 5: ...stem Configuration Diagram 7 Connecting To Power And A Network STARTING 8 8 Connecting to a PC 8 Access Product 11 Logging In ENVIRONMENT SETTINGS 12 12 System Management 14 Network Settings 15 Time S...

Страница 6: ...status LED Indicates power connection f AC Power code connection terminal Provides AC Power Name Function Description g Power switch Power on off switch h Power input terminal DC 24 V DC Power input t...

Страница 7: ...registered proper broadcasting cannot be performed The IP audio module can be used as an IP speaker when connected to an analog speaker with a permissible input of 10W or higher and an impedance of 8...

Страница 8: ...sswords Use Device Manager to set the initial password and IP address to use Registering using Device Manager If the product is connected to a network which includes a computer where the device manage...

Страница 9: ...are not used in the network audio product 4 Products with IP addresses must be logged in from the Credential menu to be queried as Login OK When you execute New Project Search authentication is cancel...

Страница 10: ...l IP address into the web browser s address bar 2 The admin account password must be registered when accessing the product for the first time When the Change Password window appears please enter a new...

Страница 11: ...menu of the web page Do not disconnect the power until the system initialization is complete after pressing the RESET button of the product or during product resetting 10 M To change the network setti...

Страница 12: ...Setting System Management 2 By clicking Destination Account from Password Change select the account you want to change and set the password 3 Click the Apply button after entering a new password in th...

Страница 13: ...ck Environment Setting System Management 2 Click Reset after checking the locked account on Account lock status The lock icon is changed to unlocked and the number of retries for the account is reset...

Страница 14: ...and you must register if you wish to use the product As the log information will be deleted when the product s system is initialized please download it in advance NETWORK SETTINGS You can change the n...

Страница 15: ...ime server 2 Click Apply to apply the set Time and Date information J If the product is used in a local network environment without an external Internet connection the time information may become inco...

Страница 16: ...bsite Korean English supported g Go to the Official Website If you click Hanwha the screen will move to the Hanwha Vision Official Website M The optimal monitor resolution is 1920x1080 OPERATION MODE...

Страница 17: ...volume If the volume is adjusted the speaker volume of the Button mode property is reflected on the same level When the volume is adjusted its output volume will be reflected at the same level in the...

Страница 18: ...f the source device to Multicast and broadcast the BGM sound source of the source device to the output device the Multicast IP address and the port information of the source device will be sent to the...

Страница 19: ...an select an output group among the set groups and duplicate selection is also possible The selected group will be displayed as highlighted When you select the Source Device and group and click the St...

Страница 20: ...reconfigure it The zone device which can be broadcast is displayed as Broadcasting count Total count If you manually control the speakers in Speaker Mode while running all the broadcasts with the Cont...

Страница 21: ...register all the other speakers as Speaker mode Control Mode When you run Start Broadcasting Stop Broadcasting from the Operate Button Mode you can control the zone devices with either the TCP or UDP...

Страница 22: ...irectly uploaded on PC you can select one from the Icon list 3 Once set click the Apply button 4 If you click the View Settings button the set value can be saved as a CSV file M You can use the Contro...

Страница 23: ...de broadcast will be kept since the priority of the microphone is higher Source Name Inputs or changes the name of a source Source Type Displayed as mic CH Name Displayed as 1 mic Transmission Method...

Страница 24: ...el Displayed as audio_output_1 2 Once set click the Apply button 3 If you click the View Settings button the set value can be saved as a CSV file M As the same speakers can be registered more than onc...

Страница 25: ...oadcast as per the scenario set in the All Event Preset List if an event such as the Event Preset of the button mode RM button of the microphone device or an external signal CP of the audio module occ...

Страница 26: ...e Output setting the Contact Closure Output signal will be active until the Contact Closure INPUT is Off If Contact Closure INPUT is Off while a sound source is being broadcasted the sound source will...

Страница 27: ...lume can be set Initial value 50 input value 0 100 The output volume is reflected only to Event Preset Delay Enter the delayed time before starting scenario broadcasting once the event has taken place...

Страница 28: ...schedules the holiday schedule will not be reflected even if you upload a downloaded file For holiday schedules use the download and upload functions of the Holiday menu Copy Schedules for each month...

Страница 29: ...pecific day the schedule is set on the specific date for every month or year If you specify a date range in Month or Year and select days of the week in Everyday the schedule is set only for those day...

Страница 30: ...t has an event priority set as 2000 in the Event Preset if the schedule time for a schedule that has a priority set as 1000 in the Annual Scheduler comes up the Event Preset broadcast will stop and th...

Страница 31: ...when the product s system is initialized please download it in advance M Every input field must be filled in Special characters cannot be input in the input field Locate a mouse pointer on a failure...

Страница 32: ...f where and how they can take these items for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product and i...

Страница 33: ......

Отзывы: