Information for service company
LAE MTR12 controller configuration
Read following instructions fully before commencing any alterations
Programming the controller to the Filet Freezer and Chiller units
Commence with unit switched off
Adjust display
(
¿
and
À
keys)
to read
Step Press Display
reads
Press Display
reads
Filet Freezer
Filet Chiller
1
¿
and
À
simultaneously,
hold both and
switch unit on.
PAR
-
-
-
-
2 Set USP
Set previous
setting
-24
(sets lowest
temperature)
00
(sets lowest
temperature)
3 Set
∩
SP
Set
previous
setting
-24
(sets high point)
02
(sets high point)
4 Set RT1
Set
previous
setting
2
(sets for delayed
start)
2
(sets for delayed
start)
5 Set PF1
Set
previous
setting
Off
(switches off unit
if probe fails )
Off
(switches off unit
if probe fails )
6 Set ADJ
Set
previous
setting
-4
00
7 Set HY1
Set
previous
setting
3
(minimises
temperature
overshoot)
2
(minimises
temperature
overshoot)
8 Set - - -
-
-
On completion of the preceding steps the controller will adopt the new settings once the unit is
switched off and then switched back on again.
Adjustment
keys
Display
Set key