background image

 

 

 
 
 
 

Introduction 

 
The Filet Freezer and Filet Chiller holding cabinets have been specifically 
designed for the McDonald’s corporation to hold food products at regulated 
temperatures. 
 
Pre-frozen products are held in the Filet freezer at the regulated temperature  
of  -18°C to -24°C and chilled products are held at  1°C to 4°C in the Filet 
Chiller. 
 
 
 
 

Manufacturer’s details 

 
 

H&K (Rugby)  

1 Cosford Lane 

Swift Valley 

Rugby 

CV21 1QN 

United Kingdom 

 

Tel: +44 (0) 1788 554000 

Fax: +44 (0) 1788 554100 

 
 

 

H&K (Dublin)  

Cherry Orchard Industrial Estate 

Ballyfermont Road 

Dublin 10 

Ireland 

 

Tel: +353 (1) 6055400 

Fax: +353 (1) 6055466 

The

 

CE mark indicates that this product complies with the European 

requirements on safety, health, environment and customer protection.

 

Issue 1:1 31.10.2002  

4

Содержание 804048V

Страница 1: ...H K EUROPE Please keep in the McDonald s store equipment manual for future reference User manual Filet Freezer 804048V Filet Chiller 804800...

Страница 2: ...eration 6 Technical information 6 Maintenance 7 Troubleshooting 8 Setting operational temperature MTR12 8 Controller configuration LAE MTR12 9 Controller configuration FK207T 10 Setting operational te...

Страница 3: ...ng difficulties Disconnect power source before maintaining or repairing the unit Do not steam clean jet wash or use high pressure hoses on or in the vicinity of this unit A poorly maintained condenser...

Страница 4: ...and chilled products are held at 1 C to 4 C in the Filet Chiller Manufacturer s details H K Rugby 1 Cosford Lane Swift Valley Rugby CV21 1QN United Kingdom Tel 44 0 1788 554000 Fax 44 0 1788 554100 H...

Страница 5: ...buse or neglect of equipment Parts replaced after the one year period has elapsed are covered under warranty for 90 days Purchase record This information should be entered upon receipt of Filet Freeze...

Страница 6: ...r switching on allow 1 to 2 hours for the unit to reach operating temperature The door must be closed during this chill down period Freezer When operating temperature has been reached 18 to 24 C food...

Страница 7: ...es The condenser fins are likely to require cleaning at least once a month but the frequency will depend on unit usage and operating conditions Step Action 1 Isolate power and unplug the unit 2 Remove...

Страница 8: ...operating temperature Product loaded above 18 C 2 Condenser fins dirty 3 Operating temperature set point incorrect 4 Unit still not operating 1 Remove product until unit has reached operating temperat...

Страница 9: ...est temperature 00 sets lowest temperature 3 Set SP Set previous setting 24 sets high point 02 sets high point 4 Set RT1 Set previous setting 2 sets for delayed start 2 sets for delayed start 5 Set PF...

Страница 10: ...HILLER UNIT 1 and simultaneously and hold for approx 4sec PA Set 0 19 19 2 and simultaneously hold for approx 4sec 1 Set previous setting 32 32 3 key 6 Set previous setting 0 0 4 key r0 Set previous s...

Страница 11: ...eplace the unit E0 Cabinet probe alarm Probe type incorrect Probe fault Fit correct probe type Check probe connections E1 Evaporator probe alarm Probe type incorrect Probe fault The evaporator tempera...

Страница 12: ...er 1000 R02012 1 2 Fk207T controller Chiller 1001 R02012 1 3 Probe R02009 1 4 Compressor R01112 1 5 Capillary Tube and Drier R01201 1 6 Condenser Fan Motor R01020 1 7 Condenser Fan Blade R01021 1 8 Ma...

Страница 13: ...Freezer Wiring schematic Chiller Issue 1 1 31 10 2002 13...

Отзывы: