Read following instructions fully before commencing any alterations
FK 207T Controller configuration
Adjustment keys
Display
Set key
Programming the controller
Commence with the unit switched on
If before all of the proceeding steps are completed no key action is detected for 60 seconds
the controller will revert back to its running mode.
Step Press Display
reads
Press Display
reads
Adjust display
(
¿
and
À
keys)
to read
FREEZER UNIT
Adjust display
(
¿
and
À
keys)
to read
CHILLER UNIT
1
¿
and
À
simultaneously and
hold for approx. 4sec.
PA
Set
0
-19
-19
2
¿
and
À
simultaneously
hold for approx. 4sec.
/ 1
Set
previous
setting
-32
-32
3
À
key
/ 6
Set
previous
setting
0 0
4
À
key
r0
Set
previous
setting
3 2
5
À
key
r1
Set
previous
setting
-24 0
6
À
key
r2
Set
previous
setting
-24 2
7
À
key
c2
Set
previous
setting
2 2
8
À
key
c7
Set
previous
setting
90 90
9
À
key
c8
Set
previous
setting
100 100
10
À
key
c9
Set
previous
setting
1 1
11
À
key
d0
Set
previous
setting
0 0
12
À
key
d3
Set
previous
setting
0 0
13
À
key
d6
Set
previous
setting
1 1
On completion of the proceeding steps press
¿
and
À
keys simultaneously. The controller will
adopt the new settings.
Issue 1:1 31.10.2002
10