Troubleshooting 

 
 

Problem Cause 

 

Repair 

Unit will not 
start 
 
 
 

1.  Unit not plugged in 
  
 
2.  No power to unit 
      (controller display not 

illuminated) 

 
 
 
3.   Unit still not operating 

1.  Plug unit into relevant 

socket 

 
2.  Check store power supply  
       (isolator breaker tripped) 

 

WARNING!

 

Electricity can kill 

 
3    Contact service company

 

Unit will not 
reach 
operating 
temperature 

1.  Loaded with product prior 

to unit reaching operating 
temperature. Product 
loaded above -18°C.  

 
 
2.  Condenser fins dirty 
 
 
3. Operating temperature 

set point incorrect 

 
 
4.   Unit still not operating 

1.  Remove product until unit 

has reached operating 
temperature. Ensure 
product is at correct 
temperature prior to loading.

 
2.  Clean fins (see 

Maintenance)  

 
3.  Check controller setting 

 (see Setting operational 

temperature) 

 
4.  Contact service company 

 
 
 

Setting operational temperature MTR12

 

 

 

Setting the operating temperature of the unit 

 

 

Unit must be switched on 

 

Adjust display 

(

¿

 and 

À

 keys) 

to read

 

Press 

Filet Freezer  

Filet Chiller  

Set 

-24 01 

Issue 1:1 31.10.2002  

8

 

Содержание 804048V

Страница 1: ...H K EUROPE Please keep in the McDonald s store equipment manual for future reference User manual Filet Freezer 804048V Filet Chiller 804800...

Страница 2: ...eration 6 Technical information 6 Maintenance 7 Troubleshooting 8 Setting operational temperature MTR12 8 Controller configuration LAE MTR12 9 Controller configuration FK207T 10 Setting operational te...

Страница 3: ...ng difficulties Disconnect power source before maintaining or repairing the unit Do not steam clean jet wash or use high pressure hoses on or in the vicinity of this unit A poorly maintained condenser...

Страница 4: ...and chilled products are held at 1 C to 4 C in the Filet Chiller Manufacturer s details H K Rugby 1 Cosford Lane Swift Valley Rugby CV21 1QN United Kingdom Tel 44 0 1788 554000 Fax 44 0 1788 554100 H...

Страница 5: ...buse or neglect of equipment Parts replaced after the one year period has elapsed are covered under warranty for 90 days Purchase record This information should be entered upon receipt of Filet Freeze...

Страница 6: ...r switching on allow 1 to 2 hours for the unit to reach operating temperature The door must be closed during this chill down period Freezer When operating temperature has been reached 18 to 24 C food...

Страница 7: ...es The condenser fins are likely to require cleaning at least once a month but the frequency will depend on unit usage and operating conditions Step Action 1 Isolate power and unplug the unit 2 Remove...

Страница 8: ...operating temperature Product loaded above 18 C 2 Condenser fins dirty 3 Operating temperature set point incorrect 4 Unit still not operating 1 Remove product until unit has reached operating temperat...

Страница 9: ...est temperature 00 sets lowest temperature 3 Set SP Set previous setting 24 sets high point 02 sets high point 4 Set RT1 Set previous setting 2 sets for delayed start 2 sets for delayed start 5 Set PF...

Страница 10: ...HILLER UNIT 1 and simultaneously and hold for approx 4sec PA Set 0 19 19 2 and simultaneously hold for approx 4sec 1 Set previous setting 32 32 3 key 6 Set previous setting 0 0 4 key r0 Set previous s...

Страница 11: ...eplace the unit E0 Cabinet probe alarm Probe type incorrect Probe fault Fit correct probe type Check probe connections E1 Evaporator probe alarm Probe type incorrect Probe fault The evaporator tempera...

Страница 12: ...er 1000 R02012 1 2 Fk207T controller Chiller 1001 R02012 1 3 Probe R02009 1 4 Compressor R01112 1 5 Capillary Tube and Drier R01201 1 6 Condenser Fan Motor R01020 1 7 Condenser Fan Blade R01021 1 8 Ma...

Страница 13: ...Freezer Wiring schematic Chiller Issue 1 1 31 10 2002 13...

Отзывы: