Troubleshooting
Problem Cause
Repair
Unit will not
start
1. Unit not plugged in
2. No power to unit
(controller display not
illuminated)
3. Unit still not operating
1. Plug unit into relevant
socket
2. Check store power supply
(isolator breaker tripped)
WARNING!
Electricity can kill
3 Contact service company
Unit will not
reach
operating
temperature
1. Loaded with product prior
to unit reaching operating
temperature. Product
loaded above -18°C.
2. Condenser fins dirty
3. Operating temperature
set point incorrect
4. Unit still not operating
1. Remove product until unit
has reached operating
temperature. Ensure
product is at correct
temperature prior to loading.
2. Clean fins (see
Maintenance)
3. Check controller setting
(see Setting operational
temperature)
4. Contact service company
Setting operational temperature MTR12
Setting the operating temperature of the unit
Unit must be switched on
Adjust display
(
¿
and
À
keys)
to read
Press
Filet Freezer
Filet Chiller
Set
-24 01
Issue 1:1 31.10.2002
8