Maintenance
Ensure power is disconnected before attempting any maintenance work
Cleaning the condenser
The condenser (pictured below) must be kept clean in order to maintain a
clear passage through which air may pass. Air is continually drawn through
the condenser fins, along with dust, lint, paper, grease, etc. Do not allow this
dirt to build up and block vision through the fins. A clean condenser will
minimise operating, maintenance and repair expenses.
The condenser fins are likely to require cleaning at least once a month but
the frequency will depend on unit usage and operating conditions.
Step
Action
1
Isolate power and unplug the unit
2
Remove the protective grill from the front of the unit
3
Gently brush or vacuum the dirt from the condenser fins
4
Re-align the fins using a fin comb (H&K Ltd part number S06084)
5
Replace the cover panel
If there is a significant dirt build-up that is difficult to remove, contact a
refrigeration service company who will be able blow out the condenser with
pressurised air, CO
2
or nitrogen.
Controller
On/off
switch
Condenser
fins
Issue 1:1 31.10.2002
7