Speed and Torque of RC

M

-xxxAS Actuators   

        

Maximum Speed 

Address 0x0000 

Time for 

1 Turn 

(sec) 

Torque in in-lbs 

0x0001 = 0 

16% Power 

Torque in in-lbs 

0x0001 = 1 

33% Power 

Torque in in-lbs 

0x0001 = 2 

66% Power 

Torque in in-lbs 

0x0001 = 3 

100% Power 

 

 

12VDC 

24VDC 

12VDC  24VDC  12VDC 

24VDC 

12VDC 

24VDC 

23 

17 

   35 

28 

60 

57 

115 

70 

145 

11 

 
   Operating torque is 100%   These torque values are for valve seating. 

 

 

 

 

 

 

 

 

To convert in-lbs to Nm, divide the in-lbs value by 9

 

 
Speed and Torque of RC

H

-xxxAS Actuators   

        

Maximum Speed 

Address 0x0000 

Time for 

1 Turn 

(sec) 

Torque in in-lbs 

0x0001 = 0 

16% Power 

Torque in in-lbs 

0x0001 = 1 

33% Power 

Torque in in-lbs 

0x0001 = 2 

66% Power 

Torque in in-lbs 

0x0001 = 3 

100% Power 

 

 

12VDC 

24VDC 

12VDC  24VDC  12VDC 

24VDC 

12VDC 

24VDC 

90 

44 

120 

88 

205 

166 

400 

245 

497 

45 

 
   Operating torque is 100%   These torque values are for valve seating. 

30 

18 

 
   

 

 

 

 

 

 

To convert in-lbs to Nm, divide the in-lbs value by 9

 

 

Speed and Torque of RC

F

-xxxAS Actuators   

        

Maximum Speed 

Address 0x0000 

Time for 

1 Turn 

(sec) 

Torque in in-lbs 

0x0001 = 0 

16% Power 

Torque in in-lbs 

0x0001 = 1 

33% Power 

Torque in in-lbs 

0x0001 = 2 

66% Power 

Torque in in-lbs 

0x0001 = 3 

100% Power 

 

 

12VDC 

24VDC 

12VDC  24VDC  12VDC 

24VDC 

12VDC 

24VDC 

161 

112 

230 

170 

380 

360 

720 

450 

915 

77 

 
   Operating torque is 100%   These torque values are for valve seating. 

49 

     28 

 

 

 

 

 

 

 

 

To convert in-lbs to Nm, divide the in-lbs value by 9 

 
Speed and Torque of RC

U

-xxxAx Actuators 

Time for

1 turn

(sec)

12VDC

24VDC

12VDC

24VDC

12VDC

24VDC

12VDC

24VDC

OFF

OFF

713

490

990

1330

1674

1600

3209

2020

4045

OFF

ON

341

ON

OFF

217

ON

ON

124

DIP 1

DIP 2

Torque in in-lbs

Torque in in-lbs

Torque in in-lbs

Torque in in-lbs

16% Power*

33% Power*

66% Power*

100% Power*

 

 

 
 
 
 

Note: 66% setting and 100% setting may alter duty cycle:  

-

 

When operating above 66% power, Duty cycle is reduced to 50% - 25% maximum. At these 
levels, the electronics produce more heat which must be dissipated (depending on environmental 
temperature and torque of the valve). 

 

Содержание RC AS-1.05 Series

Страница 1: ...s pg 3 Operation pg 4 6 DIP Switch pg 4 Recalibration pg 4 Troubleshooting pg 4 Communications parameters pg 5 Speed and Torque details pg 5 6 Appendix pg 7 14 Modbus Protocol pg 7 12 Power settings p...

Страница 2: ...ower supply only 6 White 24VDC 5 Black Power Gnd 4 Pink TD A 3 Grey TD B 2 Brown Isolated Input Signal Gnd 1 Blue Isolated Input Signal 4 20mA Connect the power The RCx may be connected to voltages ra...

Страница 3: ...the picture above then connect your input signal on pos 3 and 4 as shown below ACTUATOR 1 2 3 4 5 6 P2 4 20mA Signal source user powered TD A TD B SIGNAL GND RCx Internal RES R66 NOTE 1 Usually the ac...

Страница 4: ...it one second and then put it back or use the command code 0x64 In both cases you will see the actuator closing the valve very slowly Troubleshooting Upon noticing a problem your first step should alm...

Страница 5: ...only limit the maximum speed The faster you set this maximum speed the less torque you can expect at this maximum speed as shown in the tables below NOTE Depending ONLY on the power setting address 0x...

Страница 6: ...que values are for valve seating 2 30 3 18 To convert in lbs to Nm divide the in lbs value by 9 Speed and Torque of RCF xxxAS Actuators Maximum Speed Address 0x0000 Time for 1 Turn sec Torque in in lb...

Страница 7: ...isters READ and WRITE 1 0x0001 4002 MaximumPower 2 0x0002 4003 NumberOfTurns 3 0x0003 4004 TargetFromRS485Flag 4 0x0004 4005 InputRangeLow 5 0x0005 4006 InputRangeHigh 6 0x0006 4007 OutputRangeLow 7 0...

Страница 8: ...em when in the seating mode The actuator will try to reach the speed set by MaximumSpeed If the torque required is too high the actuator will automatically slow down and deliver the maximum available...

Страница 9: ...000 in actuator number 23 0x17 0x06 0x0005 0xFDE8 0x 1 byte 1 byte 2 bytes 2 bytes 2 bytes For a detailed explanation of this two registers please see TargetPosition register description Register name...

Страница 10: ...valve 5 turns TargetPosition register has to be set to 1500 Register name Address Max Min Def Actuator address Function code Register address Register new value CRC SignalLostPosition 0x0009 InputRan...

Страница 11: ...ngeLow 0 OutputRangeHigh 10000 If CurrentPosition equals to 10000 that means the valve is 5 turns opened If CurrentPosition equals to 2000 that means the valve is 1 turns opened Example 2 If the actua...

Страница 12: ...to send Actuator address Function code Input address Qty of inputs CRC 0x21 0x02 0x0000 0x0002 0x 1 byte 1 byte 2 bytes 2 bytes 2 bytes Example 2 To read the discrete inputs 4 Stalled closed in actua...

Страница 13: ...2 0 0 1 1 0 0 13 0 0 1 1 0 1 14 0 0 1 1 1 0 15 0 0 1 1 1 1 16 0 1 0 0 0 0 17 0 1 0 0 0 1 18 0 1 0 0 1 0 19 0 1 0 0 1 1 20 0 1 0 1 0 0 21 0 1 0 1 0 1 22 0 1 0 1 1 0 23 0 1 0 1 1 1 24 0 1 1 0 0 0 25 0 1...

Страница 14: ...nbayinc com Rev 2018 1 1 800 315 4461 hanbaysales hanbayinc com Main Dimensions Desiccant sticks These sticks change colour when exposed to moisture When they change from the original colour blue to p...

Страница 15: ...HANBAY Inc User Manual RCx xxxAS 1 05 Page 15 of 15 www hanbayinc com Rev 2018 1 1 800 315 4461 hanbaysales hanbayinc com Part Number Breakdown Serial Number Full Hanbay Part Number...

Отзывы: