Hampton
®
H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove
installation
You will require the following components with
your new Direct Vent Freestanding Gas Stove.
Please review your product to make sure you
have everything you need. In the event that you
are missing any part, contact your dealer.
Note: These are the minimum pieces re
-
quired. Other parts may be required for
your particular installation. See above
for a list of vent parts.
If installing termination on a siding covered wall,
a vinyl siding standoff or furring strips can be
used in order to ensure that the termination is
not recessed into siding.
The vinyl siding standoff is required for walls with
vinyl siding.
Minimum components for a Dura-Vent
Horizontal Installation:
A) Dura-Vent Horizontal Termination Kit
B) Wall Thimble (required for combustible walls)
Minimum components for a Dura-Vent
Vertical Termination:
D) Dura-Vent Vertical Termination Kit. See above
for pipe lengths.
Diagram 2a
Horizontal Terminations
1)
Set the unit in its desired location. Check to
determine if wall studs are in the way when
the venting system is attached. If this is the
case, you may want to adjust the location of
the unit.
2)
Assemble the desired combination of pipe
and elbow to the appliance adapter with pipe
seams oriented down. Offset the pipe seams
as double seams in one place will cause the
outer pipe to take an oval shape. Kit comes
complete with 18" of straight vent - 6-5/8" dia.
black outer pipe and 4" dia. inner vent.
3)
With the pipe attached to the stove, slide the
stove into its correct location, and mark the
wall for a 9-1/2" (inside dimensions) round
hole. The center of the round hole should line
up with the centerline of the horizontal pipe,
as shown in diagram 1. Cut and frame the
9-1/2 round hole in the exterior wall where
the vent will be terminated. If the wall being
penetrated is constructed of non-combustible
material, i.e. masonry block or concrete, a 7"
diameter hole is acceptable.
a)
The horizontal run of vent should have a
1/4 inch rise for every 1 foot of run towards
the termination. Never allow the vent to run
downward. This could cause high tempera-
tures and may present the possibility of a
fire.
b)
The location of the horizontal vent termina-
tion on an exterior wall must meet all local
and national building codes, and must not be
blocked or obstructed. Refer to the "Exterior
Vent Terminal Locations" section.
c)
Snorkel Terminations:
For installations requiring a vertical rise
on the exterior of the building, 14-inch and
36-inch tall Snorkel Terminations as shown
in Diagram 2 are available, as well as the
standard Riser Vent. Follow the same in-
stallation procedures as used for standard
Horizontal Termination. NEVER install the
snorkel upside down.
Diagram 1
*Diagram 2a: As specified in CGA B149 Instal-
lation Code. Local codes or regulations may
require different clearances.
Diagram 2b
NOTE: For Snorkel terminations in ABOVE grade
installations, follow national or local code
requirements.
Below Grade Snorkel Installation
If the Snorkel Termination must be installed below
grade, i.e. basement application, proper drainage
must be provided to prevent water from enter-
ing the Snorkel Termination. Refer to Installation
instructions for details.. Do not attempt to enclose
the Snorkel within the wall, or any other type of
enclosure.
4)
Install wall penetration heat shield in the center of
the 9-1/2" round hole and attach with wood screws.
The four wood screws provided should be replaced
with appropriate fasteners for stucco, brick, concrete,
or other types of sidings. Diagram 3.
5)
If installing termination on a siding covered wall, a
vinyl siding standoff or furring strips must be used
to ensure that the termination is not recessed into
the siding. Diagram 3.
6)
Take the Riser Vent terminal and separate the Back-
ing Plate from the Riser Vent Front by removing 8
screws as shown in diagram 4.
Diagram 3