Installation Precautions
These venting systems are engineered products
that have been designed and tested for use with the
H27U-NG, and H27U-LP. The warranty will be voided
and serious fire, health or other safety hazards may
result from any of the following actions:
1)
Installation of any damaged Direct Vent com-
ponent
2)
Unauthorized modification of the Direct Vent
System
3)
Installation of any component part not manu-
factured by approved venting systems as per
table on next page or FPI Fireplace Products
International Ltd.
4)
Installation other than as instructed by approved
venting systems as per table on next page and
FPI Fireplace Products International Ltd.
Warning: Always maintain required
clearances (air spaces) to nearby
combustibles to prevent a fire hazard.
Do not fill air spaces with insulation.
Be sure to check the vent termination clearance
requirements from decks, windows, soffits, gas
regulators, air supply inlets and public walkways as
specified in the "Exterior Vent Terminal Locations"
section and in your local building codes.
The gas appliance and vent system must be
vented directly to the outside of the building,
and never be attached to a chimney serving a
separate solid fuel or gas-burning appliance.
Each direct vent gas appliance must use it's own
separate vent system. Common vent systems are
prohibited.
Venting Introduction
The Horizontal Termination Kit and other
approved venting systems as per table on next page,
in combination with the Direct Vent Freestanding
Gas Stoves, H27U-NG, and H27U-LP, have been
tested and listed as direct vent heater systems by
Warnock Hersey.
These units use the "balanced flue" technology
Co-Axial system. The inner liner vents products
of combustion to the outside while the outer pipe
draws outside combustion air into the combustion
chamber thereby eliminating the need to use heated
room air for combustion and losing warm room air
up the chimney.
Note: These flue pipes must not be
connected to any other appliance.
The gas appliance and vent system must be vented
directly to the outside of the building, and never
be attached to a chimney serving a separate solid
fuel or gas burning appliance. Each direct vent gas
appliance must use it's own separate vent system.
Common vent systems are prohibited.
IMPORTANT
Read all instructions carefully before starting the
installation. Failure to follow these instructions may
create a fire or other safety hazard, and will void the
warranty. Be sure to check the venting and clear-
ance to combustible requirements. Consult your
local building codes before beginning installation.
The location of the termination cap must conform
to the requirements in the "Exterior Vent Terminal
Locations" section.
Safety Precautions for the
Installer
1)
Wear gloves and safety glasses for protection.
2)
Exercise extreme caution when using ladders
or on roof tops.
3)
Be aware of electrical wiring locations in walls
and ceilings.
Vent Restrictor Position
To set the Vent restriction as indicated in the dia-
grams in "Venting Arrangements" section, simply
loosen the screws and push the vent restrictor plate
to the correct position. Tighten the screws.
Rotating 45
o
Elbow
1)
Remove all 4 screws that secure
the elbow to the unit using a 1/4"
magnetic nut driver.
2)
Rotate the elbow 180
o
3)
Secure the elbow by securing
it with the 4 screws.
Remove all 4 screws
and washers
Содержание H27U-NG
Страница 49: ...49 Hampton H27U NG H27U LP Direct Vent Freestanding Gas Stove notes...
Страница 54: ...54 Hampton H27U NG H27U LP Direct Vent Freestanding Gas Stove warranty...
Страница 55: ......