4
Hampton
®
H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove
safety label
This is a copy of the label that accompanies each Direct Vent Freestanding Gas Stove. We have printed a copy of the contents here for your review.
NOTE:
Hampton
®
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Copy of Safety Label
5" WC/C.E. (1.25 kPa)
3.5" WC/C.E. (0.87 kPa)
1.6" WC/C.E. (0.40 kPa)
11" WC/C.E. (2.74 kPa)
10" WC/C.E. (2.49 kPa)
6.4" WC/C.E. (1.59 kPa)
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
DUPLICATE SERIAL NO.
DO NOT REMOVE THIS LABEL
561
561
FPI Fireplace Products International Ltd. Delta, BC, Canada
Made in Canada
Minimum Clearances to Combustibles
C 2" / 50mm
E 2"/50mm
A 6"/150mm
B 3"/75mm
Minimum ceiling height from top of unit: 24"/610mm
Minimum clearance of Vent Terminal
to Outside Corner & Inside Corner:
with AstroCap 6"/150mm
with Dura-Vent Cap 12"/300mm
Serial No.
Maximum Input
Minimum Input
Orifice size
Altitude
Maximum Input
Minimum Input
Orifice size
Altitude
FACTORY EQUIPPED FOR NATURAL GAS
Model:H27U-NG
FACTORY EQUIPPED FOR PROPANE GAS
Model:H27U-LP
Left Side Wall
Right Side Wall
Horizontal
Pipe
25,000 Btu/h (7.32 Kw/h)
18,000 Btu/h (5.28 Kw/h)
#42 DMS (2.37mm)
0-4500 ft/pi (0-1372m)
22,000 Btu/h (6.45 Kw/h)
17,500 Btu/h (5.13 Kw/h)
#54 DMS (1.4mm)
0-4500 ft/pi (0-1372m)
Left Side Wall
Right Side Wall
Vertical
Pipe
See Manual for details
Model/Modèle:
H27U-NG
Model/Modèle:
H27U-LP
Part #: 920-417
Colour: Everything black on grey except for items indicated as being printed in red.
Size:
Printed at 100% 6.0’’Wx6.99" H
Material: 2 ml silver matt polyester (DPM SMS)
11/04/21 : Certification updated
*
Printer
: Start number sequence @ 044000001
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
Listed:
VENTED GAS FIREPLACE HEATER /
Certified to/Certifi :
ANSI Z21.88-2019
é
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or
Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable,
ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. Optional Fan Kit (Part # 357-917)
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS. CATEGORY I.
For Use Only with Barrier (Part # 743-100) Follow installation instructions.
ELECTRICAL SUPPLY:115V_60HZ less than 2 AMP
Refer to Intertek's Directory of Building Products for detailed information.
920-417
4001172
Decal Location
Fold down access door, and then remove two screws
as shown below
With the panel removed, the gas valve will be visible.
The rating plate will be attached to a black chain
located under the IFC.
DO NOT REMOVE THE DECAL FROM THE UNIT.
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas fitter licensed in the Commonwealth
of Massachusetts.
For the State of Massachusetts, flexible
connectors shall not exceed 36 inches
in length.
For the State of Massachusetts, the ap-
pliances individual manual shut-off must
be a t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm
in accordance with NFPA 720 and a CO
alarm with battery back up in the same
room where the gas appliance is installed.