 H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove

installation

DV Stove Horizontal Vent Kit (#946-116 & #946-216) Installation

Review the following sequence of instructions which are typical of most installations. The sequence may vary depending on wall thickness. 

See the "Exterior 

Vent Terminal Locations"  section for vent 
location and clearance dimensions, and "Vent 
Restrictor Position" section to set the  Vent 
Restrictor to the correct position.

1)  Set the unit in its desired location. Check to 

determine if wall studs will be in the way of the 
venting system, adjust location until all clear-
ances are met and there are no obstructions.

Note:  A 1-1/2"(38mm) clearance around the 

outer pipe must be maintained except 

that  only  a  1"  (25mm)  clearance  is 

needed at the termination end. 

IMPORTANT:

Do not locate termination hood where ex

-

cessive snow or ice buildup may occur. Be 

sure to check vent termination area after 

snow falls, and clear to prevent accidental 

blockage of venting system. When using 

snow  blowers,  make  sure  snow  is  not 

directed towards vent termination area.

2)  Assemble a 

trial fit

 to determine the vertical 

centerline for the vent termination.

 

a)  Cut a 9-1/2" x 9-1/2" (241mm x 241 mm) 

square hole on both the interior and ex-

terior wall.

 

b)  Install wall thimbles on both interior and 

exterior wall with 4 wood screws (#8 x 

1") per thimble.

 

c)  Attach the 2 piece adjustable pipe sec-

tion to the vent terminal and slide into 

position from the exterior. 

Adapter

Trim Collar

4" ID Liner

Spacer

Spring

Thimble

Cover

Termination Cap

(Part# 946-523/P)

AstroCap

Wall Thimble

(required for

combustible walls)

Adjustable Pipe

Length 13-1/2" - 24",

2 pieces

4 ft. Pipe Length
with Kit # 946-216
or 2 ft. Pipe Length with
Kit # 946-116

Trim

Collar

DV Stove Horizontal Vent Kit

DV 2 ft.  Stove Vent Kit (Part # 946-116)  and DV 4 ft. Stove Vent Kit (946-216) includes all the parts needed 
to install the H27U-NG Direct Vent unit with minimum horizontal and vertical vent dimensions. For installations 
that require longer vertical and/or horizontal vents use the Dura-Vent system as shown in the "Dura-Vent 
Termination Kit" and "Dura-Vent Venting Components" sections.

    Qty. 

Description

1)

  1    Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length,

 

 

  Kit # 946-216: 4 ft. (1.2m) length), 6-1/2" (165mm) 

 

 

  inside diameter 

2)

  1    Flex Liner, compressed aluminium 2 ply liner, 4" (102mm) 

 

 

  inside diameter

3)

  4    spring spacers

4)

  1    90 deg. Elbow

5)

  1    Adjustable pipe section 13-1/2" to 24" (343mm x 610mm), 2 pcs.

6)

  1    Thimble Cover

7) 

1    Wall Thimble (2 pcs.)

8)

  1    Adapter 

9)

  1   

AstroCap

 Termination Cap

10)

 2    Trim Collars

11)

 1    Tube of Mill-Pac, high temperature sealant

12)

 12    Screws, #8 x 1/2" Self tapping, Stainless Steel

13)

 14    Screws, #8 x 1/2" Self tapping, Black

14)

 4    Screws #8 x 1-1/2" Drill Point, Black

15)

 4    Screws #8 x 1-1/2" Drill Point, Stainless Steel

16)

 8    Wood screws #8 x 1"

Note: 
a)  Liner sections should be continu-

ous without any joints or seams.

b)  This is an approved system, there-

fore components in this system 
must not be substituted for any 
other manufacturer's products.

  

The larger diameter end of the adjustable 

pipe goes to the vent terminal.

 

d)  Install the 90

o

 elbow onto the adjustable pipe  

to determine the vertical centerline. 

    Note: if the centerline cannot be met, the 

adjustable sections will have to be cut.

  e)  Cut the 4 ft. section of rigid pipe to length. 

Attach the  45

o

 elbow to the rigid pipe, and 

ensure that the pipe length when cut  (with 

the 45

o

 elbow) will seat onto both the starter 

collar and the 90

o

 elbow. 

 Crimped section 

of rigid pipe seats into the 90

o

 elbow. Only 

cut the uncrimped side of pipe. 

 

Dismantle all pipe sections including vent terminal.

3)  Attach the 4" dia. flex liner to the vent terminal 

ensuring that the flex overlaps the collar of the 
vent terminal by a minimum of 1-3/8"(35mm). Use 
Mill-Pac to seal and secure with 3 of the #8 x 1/2" 
screws (stainless steel). 

 
4)  Attach  the  adjustable  pipe  section  to  the  vent 

terminal using Mill-Pac and/or high temperature 
silicone and attach with 3 of the #8 x 1/2" screws 
(stainless steel).

Содержание H27U-LP

Страница 1: ...What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Foll...

Страница 2: ...Class IIIA 2 Permanent Label 4 34 6 Instruction Plate Each appliance shall bear a Class IIIB marking with letters on a contrasting background located adjacent to the controlling device or in an equall...

Страница 3: ...ws 22 Vertical Termination with Co linear Flex System 23 DV Stove Horizontal Vent Kit 24 DV Stove Horizontal Vent Kit 946 116 946 216 Installation 24 Residential and Manufactured Homes Mobile Homes Mi...

Страница 4: ...GAS FIREPLACE HEATER Certified to Certifi ANSI Z21 88 2019 This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 or Natural Gas...

Страница 5: ...Venting 24 9 16 624mm 23 5 16 592mm 27 3 16 691mm 17 7 8 454mm 18 3 16 461mm 19 5 8 498mm 24 7 8 631mm 24 9 16 624mm 23 5 16 592mm 27 3 16 691mm 15 5 8 397mm 18 15 16 481mm 28 13 16 732mm 18 3 16 461...

Страница 6: ...allum e manuellement Respectez les instructions ci dessous la lettre B AVANT LA MISE EN MARCHE reniflez tout autour de l appareil pour d celer une odeur de gaz Reniflez au niveau du plancher car certa...

Страница 7: ...rade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS...

Страница 8: ...the unit converted to top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration com...

Страница 9: ...l Was the air shutter on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if ins...

Страница 10: ...CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACETEMPERATURES ESPECIALLY THE FIREPLACE GLASS AND...

Страница 11: ...ped with a means to secure the unit This Hampton Mobile Manufactured Home listed appliance comes equipped with a dedicated 8 ground lug to which an 18 gauge copper wire from the steel chassis ground m...

Страница 12: ...d Minimum Horizontal Termination e Dura Vent Termination Kit 5 Make gas connections Refer to the Gas Con nection section Test the pilot Must be as per diagram in the Maintenance Instruction section I...

Страница 13: ...al Fan Installation Fan Kit Contains Qty Description 1 Fan Assembly c w green wire attached 1 Thermodisc 1 Power Cord 2 2 1 4 x 20 Hex Nut 1 Fan Speed Control 3 Clip Wire Holders 1 a Remove the rear a...

Страница 14: ...0 hex head 12 Before re attaching the rear access panel connect live wire black from fan to black wire 704 from speed controller Use the clip wire holders to organize the wires 13 Slide the Rear Acces...

Страница 15: ...d and listed as direct vent heater systems by Warnock Hersey These units use the balanced flue technology Co Axial system The inner liner vents products of combustion to the outside while the outer pi...

Страница 16: ...ide of center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion a...

Страница 17: ...Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46...

Страница 18: ...stroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent Termina...

Страница 19: ...Vent Direct Vent American Metal Products Ameri Vent Direct Vent Security Secure Vent Selkirk Direct Temp and ICC Excel AstroCapTM is a proprietary trademark of FPI Fireplace Products International Lt...

Страница 20: ...ded area in the diagram below shows all allowable combinations of straight vertical and offset to vertical runs with vertical terminations Maximum two 45o elbows IftheventisENCLOSEDinachase min size9...

Страница 21: ...min of 8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 feet total...

Страница 22: ...e min 1 foot be tween90o elbowsisrequired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min With these options max total pipelengthis30feetwithmin of6feettotalvertica...

Страница 23: ...e chimney See the Venting Arrangements chart below for minimum and maximum flue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys ma...

Страница 24: ...NGDirectVentunitwithminimumhorizontalandverticalventdimensions Forinstallations that require longer vertical and or horizontal vents use the Dura Vent system as shown in the Dura Vent Termination Kit...

Страница 25: ...ra 12 to 16 of length this will make the final assembly easier to work with 9 Secure the 4 dia flex liner to the 4 adapter with Mill Pac and 3 of the 8 x 1 2 screws stainless steel 10 Slide the decora...

Страница 26: ...particular requirements Determine the minimum clearance to combustibles from the rear of the unit to the wall It is also important to note the wall thickness Before cutting the vent hole through the w...

Страница 27: ...tical to horizontal type installations Warning Always maintain required clearances air spaces to nearby combustibles to prevent a fire hazard Do not fill air spaces with insulation Theminimumclearance...

Страница 28: ...ng penetrated is constructed of non combustible material i e masonry block or concrete a 7 diameter hole is acceptable a The horizontal run of vent should have a 1 4 inch rise for every 1 foot of run...

Страница 29: ...nstallation NOTE For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every in ner pipe connection Failure to do so...

Страница 30: ...drafting or per formance issues not covered under warranty Silicone redRTV isoptional 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though th...

Страница 31: ...through the ceiling support box until it protrudes approximately 3 76mm Connect the flex pipe to the Retro Connectorbyslippingitintothe4 3 4 dia meter sleeve on the top side of the Connector Use 3 sh...

Страница 32: ...ral Gas min 5 0 w c Propane min 12 0 w c Manifold Pressure Natural Gas 3 8 0 2 w c Propane 11 0 2 w c 8 Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails slide...

Страница 33: ...n finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do not over tighten Aeration Adjustmen...

Страница 34: ...gas supply 2 a Lift off the Cast Top and Cast Front remove the glass front refer to Glass ReplacementsectionintheH27manual and carefully remove the logs and lava rock refer to Log Installation sectio...

Страница 35: ...shown in Fig 4 rotate the screw clockwise until snug do not overtighten 13 Verify that if the conversion is from NG to LPG the screw must be re assembled with the red o ring visible Fig 5 14 Re assemb...

Страница 36: ...the dia grams Ifthelogsarebrokendonotusetheunituntiltheyare replaced Broken logs can interfere with the pilot operation The gas log kit Part 350 930 contains the following a Rear Log b Left Side Fron...

Страница 37: ...ntoftheburner in and around where the embers are placed Avoid stacking platinum embers 6 Place the center cross log D so it rests in the notch located on the top of the rear log position as shown belo...

Страница 38: ...H on the gas valve Use table below to determine the maximum wire length Note Preferable if the thermostat is installed on an interior wall Hampton offers an optional programmable thermostat but any 25...

Страница 39: ...eration Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges Final Check Before leaving this unit with the customer the installer must ensure that the appliance is...

Страница 40: ...rom manufactur ing Smoke detectors in the house may go off at this time Open a few windows to ventilate the room for a couple of hours The glass may require cleaning DONOTATTEMPTTOCLEANTHEGLASSWHILE I...

Страница 41: ...um e manuellement Respectez les instructions ci dessous la lettre B AVANT LA MISE EN MARCHE reniflez tout autour de l appareil pour d celer une odeur de gaz Reniflez au niveau du plancher car certains...

Страница 42: ...and OFF a dull clicking sound may be audible this is normal operation of a gas regulator or valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates...

Страница 43: ...calsupportssuch as Wall Straps or plumbers tape for rigidity 5 Verify proper operation after servicing Log Replacement Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and allow the unit...

Страница 44: ...y simply reverse these instructions Toremovevalvefromvalveassembly continue 14 Remove two 2 thermopile wires 15 Remove thermocouple with a 9 mm metric wrench 16 Remove pilot nut with an 11 mm wrench 1...

Страница 45: ...in the list should be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates...

Страница 46: ...rame Gasket 51 942 117 Top Relief Frame 52 W260280 Top Relief Plate Gasket 53 770 066F Top Relief Plate 54 904 012 Capscrew1 4x1 3 4NC Each 55 Side Shield 57 W260108 Gasket for Inner Flue 58 W842051 G...

Страница 47: ...ton H27U NG H27U LP Direct Vent Freestanding Gas Stove parts list 4 2 57 5 5 5 5 30 79 44 79 45 55 144 30 1 54 54 51 52 53 50 19 24 59 38 146 149 148 137 136 135 134 150 4 153 43 152 151 23 151 Main A...

Страница 48: ...Extension Knob ON OFF Pilot 78 910 372 Extension Knob Hi Low 79 910 341 Thermopile 910 386 Thermocouple 910 030 Spark Electrode 910 096 3 Way Pilot Hood Part Description 910 432 Pilot Tube With Nuts...

Страница 49: ...49 Hampton H27U NG H27U LP Direct Vent Freestanding Gas Stove notes...

Страница 50: ...tion Control Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media C...

Страница 51: ...downdrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lac...

Страница 52: ...utside the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the a...

Страница 53: ...n below in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Pr...

Страница 54: ...54 Hampton H27U NG H27U LP Direct Vent Freestanding Gas Stove warranty...

Страница 55: ......

Страница 56: ...ation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ________________________________________________...

Отзывы: