H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove
installation
Offset to Vertical Terminations
Venting Arrangements - Horizontal Terminations Using Dura-Vent Venting Sand/or Riser Vent Termination
The two diagrams show all allowable combinations of straight horizontal termination with one 45
o
elbow off the unit with Snorkels or FPI Riser
Snorkel Termination
Riser Vent Termination
Venting Arrangements
Vertical Terminations Systems for Residential Manufactured and
Mobile Homes
The shaded area in the diagram below shows all allowable combinations of straight
vertical and offset to vertical runs with vertical terminations.
Maximum two 45
o
elbows
.
If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.
May be installed in Manufactured (Mobile) Homes after first sale.
Horizontal Terminations for All Venting
Systems
The shaded areas in the diagram below show all al-
lowable combinations of vertical runs with horizontal
terminations. Maximum one 90
O
elbow (two 45
o
elbows
equal one 90
o
elbow).
Propane and Natural Gas: Residential,
Manufactured and Mobile Homes
Installations
May be installed in Manufactured (Mobile) Homes
after first sale.
Vent. Restrictor position "A".