25
Hampton
®
H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove
installation
installation refer to the
Dura-Vent Termination
instructions.
5) Slide the partially connected pipe and vent
terminal assembly through the wall thimbles
(from the exterior into the interior) and secure
the cap to the exterior wall with 4 of the supplied
NOTE: For best results and optimum perfor
-
mance with each approved venting sys
-
tem, it is highly recommended to apply
“Mill-Pac” sealant (supplied) to every
inner pipe connection. Failure to do so
may result in drafting or performance
issues not covered under warranty.
Silicone (red RTV) is optional.
Note: The pipe seam should be facing down.
Note: To make the installation more aestheti
-
cally pleasing, we recommend framing
out a square that the cap can be mounted
on.
Note: If installing termination on a siding
covered wall, a vinyl siding standoff or
furring strips must be used to ensure
that the termination is not recessed
into the siding. For vinyl siding standoff
screws (#8 x 1-1/2" drill point, stainless steel).
Note: pilot holes will need to be drilled through
the wall thimble on all 4 corners.
Note: The four screws pro
-
vided for the vent cap
should be replaced
with appropriate fas
-
teners for stucco,
brick, concrete, or
other types of sid
-
ings.
6) A bead of non-hardening mastic should be run
around both the termination and vinyl siding
standoff to prevent water from entering and
to make a tight seal between the cap and the
standoff.
7) Stretch the 4" dia. flex liner out fully and get a
trial fit of the liner onto the 4" dia. starter collar.
8) Cut the 4" dia. flex liner to the desired size.
Hint: leave an extra 12" to 16" of length, this will
make the final assembly easier to work with.
9) Secure the 4" dia. flex liner to the 4" adapter
with Mill-Pac and 3 of the #8 x 1/2" screws
(stainless steel).
10) Slide the decorative Thimble Cover over the
pipe sections and secure with 4 screws (#8 x
1-1/2" drill point, black) to the wall.
11) Slide the 90
o
elbow (crimp end up), the 45
o
elbow and the 4 ft. pipe section (crimp end up)
over the 4" dia. flex liner.
12) Install the spring spacers onto the pipe sections.
13) Secure the 4" dia. flex liner with adapter onto
the stove collar. Put a bead of Mill-Pac around
the appliance adapter and secure with 3 screws
(#8 x 1/2, stainless steel).
14) Attach the 45
o
elbow onto the starter collar by
sealing with Mill-Pac and/or high temperature
silicone and securing with 3 of the #8 x 1/2"
(black) screws.
15) Attach the pipe section to the 45
o
elbow by
sealing with Mill-Pac and/or high temperature
silicone and securing with 3 of the #8 x 1/2"
screws (black). Pipe seams should be facing
the wall.
16) Attach the 90
o
elbow onto the pipe section by
sealing with Mill-Pac and/or high temperature
silicone and securing with 3 of the #8 x 1/2"
screws (black).
17) Slide the adjustable pipe section onto the 90
o
elbow. Slide the trim collar over the adjustable
pipe sections to cover the joint of the telescopic
section.) The flex may have to be compressed
back in order for the adjustable pipe to properly
mate to the elbow. Seal with Mill-Pac and/or
high temperature silicone and secure with 3 of
the #8 x 1/2" screws (black). Pipe seams facing
down.
18) Install the trim collar over the starter collar and
secure with a #8 x 1/2" screw (black).
If the pipe needs to be touched up, use only Stove
Brite High Temperature Metallic Black Stove Paint.
Outside
Wall
Mur extérieur
Furring
Strips
Fourrures en bois
Furstrp.eps
see also c34020a.eps
furstrpf.eps
french
Содержание H27U-LP
Страница 49: ...49 Hampton H27U NG H27U LP Direct Vent Freestanding Gas Stove notes...
Страница 54: ...54 Hampton H27U NG H27U LP Direct Vent Freestanding Gas Stove warranty...
Страница 55: ......