 H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove

installation

You  will  require  the  following  components  with 
your new  Direct Vent Freestanding Gas Stove. 
Please  review  your  product  to  make  sure  you 
have everything you need. In the event that you 
are missing any part, contact your dealer. 

Note:  These  are  the  minimum  pieces  re

-

quired. Other parts may be required for 

your particular installation. See above 

for a list of vent parts.

If installing termination on a siding covered wall, 
a  vinyl  siding  standoff  or  furring  strips  can  be 
used  in  order  to  ensure  that  the  termination  is 
not recessed into siding.

The vinyl siding standoff is required for walls with 
vinyl siding.

Minimum components for a Dura-Vent
Horizontal Installation:

A)  Dura-Vent Horizontal Termination Kit
B)  Wall Thimble (required for combustible walls)

Minimum components for a Dura-Vent
Vertical Termination:

D)  Dura-Vent Vertical Termination Kit. See above 

for pipe lengths.

Diagram 2a

Horizontal Terminations

1)

  Set the unit in its desired location. Check to 

determine if wall studs are in the way when 
the venting system is attached. If this is the 
case, you may want to adjust the location of 
the unit.

2)

  Assemble  the  desired  combination  of  pipe 

and elbow to the appliance adapter with pipe 
seams oriented down. Offset the pipe seams 
as double seams in one place will cause the 
outer pipe to take an oval shape. Kit comes 
complete with 18" of straight vent - 6-5/8" dia. 
black outer pipe and 4" dia. inner vent. 

3)

  With the pipe attached to the stove, slide the 

stove into its correct location, and mark the 
wall for a   9-1/2" (inside dimensions) round 
hole. The center of the round hole should line 
up with the centerline of the horizontal pipe, 
as  shown  in  diagram  1.  Cut  and  frame  the 
9-1/2  round  hole  in  the  exterior  wall  where 
the vent will be terminated. If the wall being 
penetrated is constructed of non-combustible 
material, i.e. masonry block or concrete, a  7" 
diameter hole is acceptable.

a)

  The  horizontal  run  of  vent  should  have  a            

1/4 inch rise for every 1 foot of run towards 
the termination. Never allow the vent to run 
downward. This could cause high tempera-
tures and may present the possibility of a 
fire.

b)

  The location of the horizontal vent termina-

tion on an exterior wall must meet all local 
and national building codes, and must not be 
blocked or obstructed. Refer to the "Exterior 
Vent Terminal Locations" section.

c)

 

Snorkel Terminations:

 

For  installations  requiring  a  vertical  rise 
on the exterior of the building, 14-inch and 
36-inch tall Snorkel Terminations as shown 
in Diagram 2 are available, as well as the 
standard  Riser  Vent.  Follow  the  same  in-
stallation procedures as used for standard 
Horizontal Termination.  NEVER  install  the 
snorkel upside down.

 

Diagram 1

*Diagram 2a: As specified in CGA B149 Instal-
lation  Code.  Local  codes  or  regulations  may 
require different clearances.

Diagram 2b

NOTE: For Snorkel terminations  in ABOVE  grade 

installations, follow national or local code 

requirements.

 

 Below Grade Snorkel Installation

       If the Snorkel Termination must be installed below 

grade, i.e. basement application, proper drainage 
must  be  provided  to  prevent  water  from  enter-
ing the Snorkel Termination. Refer to Installation 
instructions for details.. Do not attempt to enclose 
the  Snorkel  within  the  wall,  or  any  other  type  of 
enclosure.

4)

  Install wall penetration heat shield in the center of 

the 9-1/2" round hole and attach with wood screws. 
The four wood screws provided should be replaced 
with appropriate fasteners for stucco, brick, concrete, 
or other types of sidings. Diagram 3.

5)

   If installing termination on a siding covered wall, a 

vinyl siding standoff or furring strips must be used 
to ensure that the termination is not recessed into 
the siding.  Diagram 3.

6)

  Take the Riser Vent terminal and separate the Back-

ing Plate from the Riser Vent Front by removing 8 
screws as shown in diagram 4.

Diagram  3

Содержание H27U-LP

Страница 1: ...What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Foll...

Страница 2: ...Class IIIA 2 Permanent Label 4 34 6 Instruction Plate Each appliance shall bear a Class IIIB marking with letters on a contrasting background located adjacent to the controlling device or in an equall...

Страница 3: ...ws 22 Vertical Termination with Co linear Flex System 23 DV Stove Horizontal Vent Kit 24 DV Stove Horizontal Vent Kit 946 116 946 216 Installation 24 Residential and Manufactured Homes Mobile Homes Mi...

Страница 4: ...GAS FIREPLACE HEATER Certified to Certifi ANSI Z21 88 2019 This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 or Natural Gas...

Страница 5: ...Venting 24 9 16 624mm 23 5 16 592mm 27 3 16 691mm 17 7 8 454mm 18 3 16 461mm 19 5 8 498mm 24 7 8 631mm 24 9 16 624mm 23 5 16 592mm 27 3 16 691mm 15 5 8 397mm 18 15 16 481mm 28 13 16 732mm 18 3 16 461...

Страница 6: ...allum e manuellement Respectez les instructions ci dessous la lettre B AVANT LA MISE EN MARCHE reniflez tout autour de l appareil pour d celer une odeur de gaz Reniflez au niveau du plancher car certa...

Страница 7: ...rade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS...

Страница 8: ...the unit converted to top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration com...

Страница 9: ...l Was the air shutter on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if ins...

Страница 10: ...CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACETEMPERATURES ESPECIALLY THE FIREPLACE GLASS AND...

Страница 11: ...ped with a means to secure the unit This Hampton Mobile Manufactured Home listed appliance comes equipped with a dedicated 8 ground lug to which an 18 gauge copper wire from the steel chassis ground m...

Страница 12: ...d Minimum Horizontal Termination e Dura Vent Termination Kit 5 Make gas connections Refer to the Gas Con nection section Test the pilot Must be as per diagram in the Maintenance Instruction section I...

Страница 13: ...al Fan Installation Fan Kit Contains Qty Description 1 Fan Assembly c w green wire attached 1 Thermodisc 1 Power Cord 2 2 1 4 x 20 Hex Nut 1 Fan Speed Control 3 Clip Wire Holders 1 a Remove the rear a...

Страница 14: ...0 hex head 12 Before re attaching the rear access panel connect live wire black from fan to black wire 704 from speed controller Use the clip wire holders to organize the wires 13 Slide the Rear Acces...

Страница 15: ...d and listed as direct vent heater systems by Warnock Hersey These units use the balanced flue technology Co Axial system The inner liner vents products of combustion to the outside while the outer pi...

Страница 16: ...ide of center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion a...

Страница 17: ...Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46...

Страница 18: ...stroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent Termina...

Страница 19: ...Vent Direct Vent American Metal Products Ameri Vent Direct Vent Security Secure Vent Selkirk Direct Temp and ICC Excel AstroCapTM is a proprietary trademark of FPI Fireplace Products International Lt...

Страница 20: ...ded area in the diagram below shows all allowable combinations of straight vertical and offset to vertical runs with vertical terminations Maximum two 45o elbows IftheventisENCLOSEDinachase min size9...

Страница 21: ...min of 8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 feet total...

Страница 22: ...e min 1 foot be tween90o elbowsisrequired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min With these options max total pipelengthis30feetwithmin of6feettotalvertica...

Страница 23: ...e chimney See the Venting Arrangements chart below for minimum and maximum flue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys ma...

Страница 24: ...NGDirectVentunitwithminimumhorizontalandverticalventdimensions Forinstallations that require longer vertical and or horizontal vents use the Dura Vent system as shown in the Dura Vent Termination Kit...

Страница 25: ...ra 12 to 16 of length this will make the final assembly easier to work with 9 Secure the 4 dia flex liner to the 4 adapter with Mill Pac and 3 of the 8 x 1 2 screws stainless steel 10 Slide the decora...

Страница 26: ...particular requirements Determine the minimum clearance to combustibles from the rear of the unit to the wall It is also important to note the wall thickness Before cutting the vent hole through the w...

Страница 27: ...tical to horizontal type installations Warning Always maintain required clearances air spaces to nearby combustibles to prevent a fire hazard Do not fill air spaces with insulation Theminimumclearance...

Страница 28: ...ng penetrated is constructed of non combustible material i e masonry block or concrete a 7 diameter hole is acceptable a The horizontal run of vent should have a 1 4 inch rise for every 1 foot of run...

Страница 29: ...nstallation NOTE For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every in ner pipe connection Failure to do so...

Страница 30: ...drafting or per formance issues not covered under warranty Silicone redRTV isoptional 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though th...

Страница 31: ...through the ceiling support box until it protrudes approximately 3 76mm Connect the flex pipe to the Retro Connectorbyslippingitintothe4 3 4 dia meter sleeve on the top side of the Connector Use 3 sh...

Страница 32: ...ral Gas min 5 0 w c Propane min 12 0 w c Manifold Pressure Natural Gas 3 8 0 2 w c Propane 11 0 2 w c 8 Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails slide...

Страница 33: ...n finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do not over tighten Aeration Adjustmen...

Страница 34: ...gas supply 2 a Lift off the Cast Top and Cast Front remove the glass front refer to Glass ReplacementsectionintheH27manual and carefully remove the logs and lava rock refer to Log Installation sectio...

Страница 35: ...shown in Fig 4 rotate the screw clockwise until snug do not overtighten 13 Verify that if the conversion is from NG to LPG the screw must be re assembled with the red o ring visible Fig 5 14 Re assemb...

Страница 36: ...the dia grams Ifthelogsarebrokendonotusetheunituntiltheyare replaced Broken logs can interfere with the pilot operation The gas log kit Part 350 930 contains the following a Rear Log b Left Side Fron...

Страница 37: ...ntoftheburner in and around where the embers are placed Avoid stacking platinum embers 6 Place the center cross log D so it rests in the notch located on the top of the rear log position as shown belo...

Страница 38: ...H on the gas valve Use table below to determine the maximum wire length Note Preferable if the thermostat is installed on an interior wall Hampton offers an optional programmable thermostat but any 25...

Страница 39: ...eration Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges Final Check Before leaving this unit with the customer the installer must ensure that the appliance is...

Страница 40: ...rom manufactur ing Smoke detectors in the house may go off at this time Open a few windows to ventilate the room for a couple of hours The glass may require cleaning DONOTATTEMPTTOCLEANTHEGLASSWHILE I...

Страница 41: ...um e manuellement Respectez les instructions ci dessous la lettre B AVANT LA MISE EN MARCHE reniflez tout autour de l appareil pour d celer une odeur de gaz Reniflez au niveau du plancher car certains...

Страница 42: ...and OFF a dull clicking sound may be audible this is normal operation of a gas regulator or valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates...

Страница 43: ...calsupportssuch as Wall Straps or plumbers tape for rigidity 5 Verify proper operation after servicing Log Replacement Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and allow the unit...

Страница 44: ...y simply reverse these instructions Toremovevalvefromvalveassembly continue 14 Remove two 2 thermopile wires 15 Remove thermocouple with a 9 mm metric wrench 16 Remove pilot nut with an 11 mm wrench 1...

Страница 45: ...in the list should be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates...

Страница 46: ...rame Gasket 51 942 117 Top Relief Frame 52 W260280 Top Relief Plate Gasket 53 770 066F Top Relief Plate 54 904 012 Capscrew1 4x1 3 4NC Each 55 Side Shield 57 W260108 Gasket for Inner Flue 58 W842051 G...

Страница 47: ...ton H27U NG H27U LP Direct Vent Freestanding Gas Stove parts list 4 2 57 5 5 5 5 30 79 44 79 45 55 144 30 1 54 54 51 52 53 50 19 24 59 38 146 149 148 137 136 135 134 150 4 153 43 152 151 23 151 Main A...

Страница 48: ...Extension Knob ON OFF Pilot 78 910 372 Extension Knob Hi Low 79 910 341 Thermopile 910 386 Thermocouple 910 030 Spark Electrode 910 096 3 Way Pilot Hood Part Description 910 432 Pilot Tube With Nuts...

Страница 49: ...49 Hampton H27U NG H27U LP Direct Vent Freestanding Gas Stove notes...

Страница 50: ...tion Control Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media C...

Страница 51: ...downdrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lac...

Страница 52: ...utside the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the a...

Страница 53: ...n below in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Pr...

Страница 54: ...54 Hampton H27U NG H27U LP Direct Vent Freestanding Gas Stove warranty...

Страница 55: ......

Страница 56: ...ation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ________________________________________________...

Отзывы: