6
Installation (continued)
3
DD
Outlet Box
Installing the mounting bracket
4
EE
B
Secure the mounting plate (B) to the outlet box with machine
screws (EE).
Installing the track to the ceiling
5
F
AA
Place the linear track section (F) in the desired location on the mounting plate (B) between the two track mounting screws (A).
Mark the location of the track section (F) on the ceiling with a pencil (not included) through the mounting holes in the bottom of the
track section (F).
Attach the track section (F) to the desired location on the ceiling in one of the following ways:
Drill a 5/8 in. hole at each mark on the ceiling.
Insert toggle bolts (AA) through the track section (F), and
thread 1/2 in. toggle onto bolts.
Place the track section (F) against the ceiling, and insert the
toggle bolts (AA) into the holes until the spring open.
Tighten the bolts (AA).
5a
Connecting the wires
NOTE:
Toggle bolts (AA) should be used for standard installation into drywall, drop ceiling, or suspended ceiling
applications. Anchors (CC) are used for masonry installations ONLY.
Toggle bolt installation
□
□
□
□
□
□
□
□
□
□
□
□
Connect the wires (white wires from connector to the white
wires from the supply circuit, black wires from the connector
to the black wires from the supply circuit, and the green
ground wire from the connector to the ground wire of the
supply circuit) using the wire connectors (DD).
Wrap electircal tape (not included) around wire connectors
(DD) and make sure they are secure.
Push all excess wire and wire connectors (DD) back into the
outlet box (not included).
Align the holes in the mounting plate (B) with the holes in the
outlet box.