background image

 

 

 

WARNING:

 

This unit emits ultraviolet (UV) radiation that is harmful to humans.  Avoid exposure 

to the direct or reflected output beam.  Make certain that the appropriate output beam shields and 

optics are in place prior to energizing the unit.  All interlocks must be satisfied prior to operation; 

failure to do so may lead to hazardous conditions. 

 

 

CAUTION: 

The TLS-EQ-77H emits dangerous levels of UV radiation.  Even short exposures to 

skin or eyes may cause burns.  Ensure that only authorized personnel are in the vicinity of source 

during operation.  Personnel in vicinity of operating source should wear protective eyewear, 

clothing, and gloves.  Lighted UV warning lights and signs posted on doors to lab areas may help 

prevent accidental exposure.   

 

 

 

 

WARNING:

 

The TLS-EQ-77H utilizes an internal Class 4 IR laser capable of causing severe injury 

to eyes or skin.  Do not open or attempt to service this unit.  Contact Energetiq regarding any 

problems with the unit. 

 

 

WARNING: 

When working near the emitted light, always wear protective devices (conforming to ISO 

4007/4849/4850/4854/4855 or equivalent regulations). The lamp installed in this housing emits intense ultraviolet rays, 

which are harmful to the eyes and skin. Looking directly into the emitted light or allowing the light to fall on the skin will 

damage eyesight or cause skin burns.

  

 

WARNING: 

If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment 

may be impaired. 

The power supply must be properly grounded by the outlet to prevent electrical shocks. 

Securely plug in the power supply connector to avoid looseness or play. Loose connections may result in 

faulty operation. 

2.1.1  Definition of equipment and document symbols and designations 

Do not operate the TLS-EQ-77H if the covers are removed or is defective in any way.  Contact Energetiq if 

any problems with the equipment are suspected. 

The TLS-EQ-77H utilizes a quartz lamp containing a high-pressure gas fill.  Explosion of the lamp 

and possible injury from flying fragments can occur if the lamp is mishandled.   

Do not open the enclosure of either the Lamp or the Controller.  Dangerous invisible infrared laser 

beams and hazardous voltages exist inside the Lamp.  

Opening the chassis both voids the warranty and 

exposes the user to dangerous radiation and hazardous voltages. 

 

 

 

 

CAUTION: 

controls or adjustments or performance of procedures other than those specified 

herein may result in hazardous radiation exposure

.

 

 

 

 

 

WARNING:

 

Invisible laser radiation avoid eye or skin exposure to direct or scattered radiation 

Class 1 laser product 

Содержание ENERGETIQ LDTLS TLS-EQ-77H

Страница 1: ...Model TLS EQ 77H Laser Driven Tunable Light Source LDTLS Operation Manual Revision 4 August 2022 Part Number DOC 7682...

Страница 2: ...ical information including drawings schematics and specifications contained in this document are the property of Energetiq and shall not be reproduced in whole or in part without the written consent o...

Страница 3: ......

Страница 4: ...e Assembly 7 3 3 Optical Performance 8 3 4 Physical Specifications 8 3 5 Utility requirements 8 3 6 Environmental Requirements 9 3 7 Remote Interface 9 3 8 External interlock connection 10 4 TLS EQ 77...

Страница 5: ...es and Tools Required 25 7 2 4 Procedure 25 7 3 Fault Indicator Block Diagram 34 8 Accessories 35 9 Warranty 35 10 Drawings Schematics and Pin Assignments 35 10 1 Dimensional Drawings 36 10 1 1 Contro...

Страница 6: ...purging any beam transport space with dry nitrogen gas The TLS EQ 77H source must also be cabled correctly and connected to a power source with a protective earth ground prior to operation Refer to t...

Страница 7: ...s and skin Looking directly into the emitted light or allowing the light to fall on the skin will damage eyesight or cause skin burns WARNING If the equipment is used in a manner not specified by the...

Страница 8: ...EQ 77 laser product is designated as Class 1 during all normal operation The parameters of the non accessible internal laser are given below in Table 1 Parameter Value Wavelength 974 nm Emission Type...

Страница 9: ...ousing label notifies of a potential hazard when covers are removed 2 Manufacturer s identification label on lamp house gives the manufacturer s name and address and the model serial number and date o...

Страница 10: ...ock connection open during operation or standby the source is immediately disabled and all light output from the aperture ceases 2 6 Correct disposal of the unit When the TLS EQ 77H has finally been r...

Страница 11: ...roller contains Laser power supply Thermo electric cooler control system for laser Control electronics Status indicator LEDs Figure 2 EQ 77 Controller EQ 77 Controller Component Description 1 Power in...

Страница 12: ...ollowing has occurred in the Power Supply Controller External interlock open Controller internal temperature too high Laser power not reaching setpoint Laser temperature fault Internal power supply vo...

Страница 13: ...mini USB connector for control of the internal monochromator 8 Monochromator power supply connector DIN connector for monochromator power from external power supply 9 Optical output connector SMA conn...

Страница 14: ...80 max for temperatures up to 31 C decreasing linearly to 50 max at 35 C Pollution Degree 2 normally only non conductive pollution occasional temporary condensation possible Overvoltage Category II I...

Страница 15: ...er consumption is 350 W maximum during normal operation Some OEM versions have higher current requirements 4 1 2 Purge Gas Purge gas required for operation With no purge ozone will form from atmospher...

Страница 16: ...t be connected before AC power is applied to the Power Supply Controller 4 Connect nitrogen purge gas to the Lamp House Clean and dry nitrogen from either a Dewar or research grade N2 bottle is recomm...

Страница 17: ...an interlock jumper plug installed To use the remote interlock function connect a remote contact or solid state switch across pins 1 and 3 Mating connector is a standard 3 pin mini DIN CUI Inc part no...

Страница 18: ...ontrol If using a custom control system substitute the appropriate digital input and output lines from Section 10 3 for the switches and LEDs described below 1 With the EQ 99 RC Remote Control Module...

Страница 19: ...ntrol software Refer to the document MH1034 Mono DLL Description Jul 28 2016 pdf for a description of the software interface 6 Service Requirements There are no user serviceable parts inside the TLS E...

Страница 20: ...Adjustable torque wrench 1 4 drive 4mm Hex Bit Socket 1 4 drive 1 TLS 12 10 50 in lbs adjustable torque screwdriver 2 Phillips Torque Screwdriver Blade TLS 23 9 in lb adjustable torque screwdriver w...

Страница 21: ...able to the LDTLS and EQ 77 Power Supply Connect the Monochromator Power Supply to the LDTLS bulkhead labeled POWER Connect the USB cable to the PC and LDTLS bulkhead labeled COMM USB Connect the Remo...

Страница 22: ...uctions Visual Aid 3 a Turn the remote control ON b Wait 1 to 3 minutes for LAMP ON LED light to illuminate 4 a On the computer start the MH1034 application b Initialize the monochromator 5 Change Mon...

Страница 23: ...ep Instructions Visual Aid 6 Change Filter Wheel to Pos 2 7 Remove TLS system rear access panel Loosen the 6 access panel screws using TLS 4 8 Remove TLS system cover Loosen the 6 cover screws using T...

Страница 24: ...19 Step Instructions Visual Aid 9 On the right hand side of the TLS system remove support bracket Loosen the 4 support bracket screws using TLS 12 10 Locate the 5 shaft lock screws...

Страница 25: ...20 Step Instructions Visual Aid 11 Loosen the 5 shaft lock screws using TLS 23 12 Locate the 5 stage lock screws Caution To avoid damaging the TLS system you must perform this step...

Страница 26: ...id 13 Loosen the 5 stage lock screws using TLS 24 14 a Ensure all 5 stages are centered b If necessary center each stage using the corresponding adjustment knob Caution To avoid damaging the TLS syste...

Страница 27: ...ed on the Power Meter 16 a Locate the X1 and X2 adjustment knobs b Use fingers to adjust one knob at a time Adjust knobs until the highest value is reached on the Power Meter 17 a Locate the Y1 and Y2...

Страница 28: ...the highest value is reached on the Power Meter c Tighten the 4 monochromator screws using TLS 8 d Repeat Z X and Y adjustments until the highest value is reached on the Power Meter 19 a Tighten the 5...

Страница 29: ...and side of the system install support bracket Tighten the 4 support bracket screws using TLS 12 22 Install TLS system cover Tighten the 6 cover screws using TLS 4 23 Install TLS system rear access pa...

Страница 30: ...r desired size A R Packing tape dispenser 1 Utility knife 1 Packing foam sheets 24 x 48 x 2 1 Bubble wrap roll 24 x 100 x 1 Corrugated cardboard box 20 x 12 x 13 5 1 per TLS system Corrugated cardboar...

Страница 31: ...board box place padding material Energetiq recommends the following types of padding material Packing foam sheets Bubble wrap If necessary cut padding material using a utility knife 3 Place TLS EQ 77H...

Страница 32: ...fill empty spaces b If necessary cut padding material using a utility knife 5 a Place padding material on top of TLS EQ 77H system to fill empty space b If necessary cut padding material using a util...

Страница 33: ...ape c Leave top of box open 8 a On bottom of outer cardboard box place padding material b If necessary cut padding material using a utility knife 9 Place sealed inner cardboard box on top of padding m...

Страница 34: ...to fill empty spaces b If necessary cut padding material using a utility knife 11 a Place padding material on top of outer cardboard box to fill empty space b If necessary cut padding material using a...

Страница 35: ...sual Aid 13 If available place the following labels on the side of the outer cardboard box a Fragile label b Keep Dry label c Do Not Stack label d This Side Up label 14 If packing 2 TLS EQ 77H systems...

Страница 36: ...em box on the pallet and center the system c If packing 2 systems place second TLS EQ 77H system box on top of the first TLS EQ 77H system box and center the system as shown Ensure the heavy end of th...

Страница 37: ...he seam between the TLS EQ 77H system boxes using packing tape Make several wraps around the boxes 17 a Wrap the TLS EQ 77H system boxes using pallet wrap Wrap several times around the boxes b At the...

Страница 38: ...eces of poly strap b If packing 1 TLS EQ 77H system cut each piece of poly strap to 10 If packing 2 TLS EQ 77H systems cut each piece of poly strap to 16 c Place 2 poly straps around the pallet in bot...

Страница 39: ...lock Diagram Lamp Fault Asserted pin 3 on remote Diagnosti Safet Bulb Interlock Open Lamp Head Overtemp 85C Control Cable Not Connected Plasma Extinguished after ignition Controller Fault Asserted pin...

Страница 40: ...the interlocks are OK and either the lamp or controller interlock faults will not clear please contact the factory Condition Lamp fails to ignite after several tries Action Contact Energetiq 8 Access...

Страница 41: ...36 10 1 Dimensional Drawings 10 1 1 Controller Dimensional Drawings TLS EQ 77 Controller in mm 10 1 2 Lamp Dimensional Drawings TLS EQ 77 Lamp in mm...

Страница 42: ...FAULT 3 Pulled to digital common when OK float on FAULT CONTROLLER FAULT 4 Pulled to digital common when OK float on FAULT ISOLATED 5V SUPPLY 5 200mA maximum referenced to digital common DIGITAL COMM...

Страница 43: ...supply 5V Power 5V Return Contact or Load solid state switch Contact or Load solid state switch 5VDC supply User N C N C Pin 13 Input Contact or solid state switch 100 Pins 1 2 3 4 Pins 6 7 8 9 Pin 5...

Страница 44: ...and their functions Command Character Function Reply from EQ 77 U Increases the present laser power setpoint by 0 5 of full scale Power XX X D Decreases the present laser power setpoint by 0 5 of ful...

Страница 45: ...40 Energetiq Technology Inc 205 Lowell St Wilmington MA 01887 Phone 1 781 939 0763 Fax 1 781 939 0769 Email info energetiq com www energetiq com DOC 7682 Rev 4 8 22...