16
Step Instructions
Visual Aid
1.
Connect the test equipment and TLS-EQ-
77H system as shown:
•
Connect one end of the 1500um fiber
to the LDTLS bulkhead labeled
OPTICAL OUTPUT.
•
Hand tighten the SMA connector.
•
Connect the opposite end of the
1500um fiber to the Power Detector.
•
Hand tighten the SMA connector.
•
Connect the Power Detector to the
Power Meter.
•
Connect the Lamp Head Cable to the
LDTLS and EQ-77 Power Supply.
•
Connect the Monochromator Power
Supply to the LDTLS bulkhead labeled
POWER.
•
Connect the USB cable to the PC and
LDTLS bulkhead labeled
COMM USB.
•
Connect the Remote Control to the
EQ-77 Power Supply.
•
Connect the EQ-77 Power Supply to a
120V AC outlet.
•
Connect the Monochromator Power
Supply to a 120V AC outlet.
•
Connect the cooling lines to the
LDTLS.
•
Start the chiller and ensure there are
no leaks.
•
Set to 22° C and press START.
2.
a. Turn the Power Meter
ON
.
b. Zero the Power Meter.
c. Set
Range
to
AUTO
.
d. Set
Laser
to
500
.
e. Set
Filter
to
IN
.