MAN1544-5
53
Program
AGENT T2
AGENT T1
SREST 60
AVF
SELECT
ZONE 1 - 8
NORMAL
Z O N E S
SELECT
D AY
T I ME
CLOCK
O UT PUT S
RELAYS
FIRE FAN
AGENT
S O U NDERS
DISPLAY
########
SELECT
BELL
ZN 1 TO 8
R# Z-ALRM
1 TO 8
ALARM
ZN 1 TO 8
S E T
SNDR #
12345678
SELECT
WA R N
S Y S
ZN 1 TO 8
RELEASE
SOLENOID
F UNCTI ON
3,4,5 WIRE
SELECT
ALM OUT
ZN 1 TO 8
R# SWITCH
1 TO 8
MAN DELAY
3 0
RELEASE
P Y R O G EN
SELECT
BGD ALM 1
ZN 1 TO 8
L CS
1
RELEASE
M E T R O N
TO EDIT DISPLAY
TEXT USE
Z LABELS
R# Z-FLT
1 TO 8
INHIBIT
ZN 1 TO 8
SELECT
ACF
ZN 1 TO 8
SELECT
ASE
ZN 1 TO 8
SELECT
BGD ALM 2
ZN 1 TO 8
R E S E T
BUZZER
R# Z-ISOL
1 TO 8
R# I/P
1 TO 8
LATCH
YES / NO
ACF ISOL
YES / NO
PRESS S/W
N / O
AUTO DELAY
3 0
EOL
10uf
EOL
RES 3K3
EOL
RES4K7
MENU
ENTER
LEGEND:
PRESS ENTER TO GO TO SUB MENU, SET MENU OR UPDATE PROGRAM
PRESS MOVE FORWARD THROUGH THE MENU
PRESS MOVE FORWARD / BACKWARD THROUGH THE MENU
CANCEL
PRESS CANCEL AT ANY TIME TO BACK OUT OF THE MENU
MENU
ENTER
MENU
ENTER
MENU
ENTER
MENU
ENTER
MENU
ENTER
MENU
ENTER
MENU
ENTER
MENU
ENTER
CANCEL
M E NU
ENTER
ACF ISOL
Z O N E
S / C
Z O N E
ALARM
MENU
ENTER
Z O N E
FAULT
EOL
RES 6K8
EOL
RES 10K
PRESS SW
N / C
SELECT
Z O N E
MENU
ENTER
MENU
ENTER
ACF
ISOALTE
ACF
ISOALTE
PRESS ACF TO ISOLATE CIRCUITS EXTERNAL TO FACP
S E T
0 - 60 SEC
S E T
0 - 60 SEC
S E T
1 TO 4
RELEASE
CONSTANT
TO MOVE THROUGH THE
ALPHABET / NUMBERS
TO MOVE THROUGH
THE WORD
MENU
ENTER
EDI T
T E X T
PRESS SW
N O N E
MENU
ENTER
S E T
ZONE #
12345678
MENU
ENTER
MENU
ENTER
EDI T
T E X T
SELECT
FAN
1,2,3,4
MENU
ENTER
LATCH
SELECT
RELAY
1 TO 8
MENU
ENTER
R E S E T
MENU
ENTER
Y E S
N O
R E S E T
BUZZER
PROGRAM
MENU
ENTER
MCP ZONE
Z #
MCP ZONE
Z #
MENU
ENTER
8
1
M O V E
T H R O U GH
DAY TIME
CHANGE
DAY TIME
ASSIGN MCP
TO A ZONE
O N
O F F
MENU
ENTER
1 TO 8
1 TO 8
1 TO 4
MENU
ENTER
UPDATE MENU
O N
O F F
MENU
ENTER
UPDATE MENU
CANCEL
BACKOUT OF MENU
O N
O F F
MENU
ENTER
UPDATE MENU
MENU
ENTER
3
4
5
MENU
ENTER
NOTE:
THESE MENUS ARE ONLY
AVAILABLEIF RELAYS, FIRE
FAN, SOUNDERS HAVE
BEEN CHANGED TO YES IN
THE SYSTEM MENU
EXAMPLE OF ACTIVATING ZONE TO TURN ON/OFF SELECTED OUTPUT
EXAMPLE OF SELECTING FUNCTION WIRE TO BE USED
NON LATCH
1 TO 8
MENU
ENTER
INDICATE
STYLE
SELECT
STYLE #X
SET STYLE FROM
1 TO MAX
AVAILABLE IN
MODULE
MAX
1
PRESS SW
N/O & MECH
AS FACTORY
DEFAULT
Agent Notes: If only one trigger zone is allocated a zone then the system will be activated by one zone only.
Any trigger zone may be allocated to any zone. However when a trigger zone has been allocated
eg T1 to zone 1 then only the remaining trigger zones T2, T3 or T4 are each available to be
allocated one of the remaining detector zones.
If multiple trigger zones are allocated eg T1 - Z1, T2 - Z2, T3 - Z3 then any one zone in alarm will
operate the first stage and any other zone in alarm will operate the second stage.
AGENT T4
AGENT T3
INHIBIT LCS
BUZZER
NORMAL
SILENT