background image

Hall Technologies      2/1/2024 

  

Page 6 of 28 

 

Configuration and Operation 

 

 

HIVE KP8 AND VERSA-4K 

As mentioned before, HT-HIVE-KP8 is capable of IP control of a variety of devices but when integrated 
with our AVoIP solution, Versa-4k, the Hive KP8 can control AV switching of the encoders and decoders 
and it can use Versa, just like a Hive-Node to control devices over IR or RS-232.  

 

 

 

 

 

 

 

 

 

 

Содержание HT-HIVE-KP8

Страница 1: ...2024 Page 1 of 28 Hall Technologies 1234 Lakeshore Dr Suite 150 Coppell TX 75019 halltechav com HT HIVE KP8 All In One 8 Button User Interface and IP Controller A Member of the Hive AV Family USER MA...

Страница 2: ...m KP8 and Hive Nodes 6 Configuration and Control via Web GUI 9 Install the Hall Research Device Finder HRDF Software Tool 9 Login to WebGUI 9 Macro Settings Tab 9 Command Settings Tab 10 Device Settin...

Страница 3: ...he Hive KP8 includes integrated battery backed clock calendar allowing the user to send commands based on specific day time schedules For example each evening the Hive KP8 powers off and each morning...

Страница 4: ...Page 4 of 28 Package Contents HT HIVE KP8 1 Model HIVE KP8 Keypad 1 5VDC 2 6A Universal Power Supply 1 USB Type A to Mini USB OTG connector 1 Pre printed button labels 28 labels 1 Blank button labels...

Страница 5: ...elf the HT HIVE KP8 is capable of IP control of a variety of devices such as our HT CAM 1080PTZ our HT ODYSSEY and most displays and projectors When used with our Hive Nodes it is capable of IR RS 232...

Страница 6: ...A 4K As mentioned before HT HIVE KP8 is capable of IP control of a variety of devices but when integrated with our AVoIP solution Versa 4k the Hive KP8 can control AV switching of the encoders and dec...

Страница 7: ...rom the network switch router Control Port Connect to a compatible LAN network switch or router using a CAT5e 6 cable Power over Ethernet PoE is supported this enables the unit to be powered directly...

Страница 8: ...addressing 1 Download the HRDF software from Hall Research website on a PC 2 Installation is not necessary click on the executable file to run it The PC may ask the user to grant permission for the a...

Страница 9: ...of 28 8 For example you can assign a new Static IP address or set it to DHCP if you want the compatible LAN network to assign the address 9 A hyperlink to the attached HIVE KP8 is available to launch...

Страница 10: ...he device s IP address into the browser s address bar The login screen will appear and prompts the user for a username and password The page might take several seconds to load when first connecting Mo...

Страница 11: ...onfigure and set up The menus for both are on the left and in order of operation The intended workflow is the same for both 1 Devices Set up IP connections for devices to be controlled 2 Activities Ta...

Страница 12: ...IP Addresses or add new device connections 2 Commands Use the prebuilt commands for Hall devices or add new commands for devices that were added in the previous Add Device tab 3 KP Commands These are...

Страница 13: ...e RS232 Relay and IR as well as the Versa 4k for switching and the Serial and IR over IP ports All the TCP ports have been added so all that needs to be done is to find the device on your network and...

Страница 14: ...om the previous tab If you want to add a new device command select Add and input the device API command the needed line ending Hex and Delimiters for ASCII commands simply input the readable text foll...

Страница 15: ...The commands can be associated with button presses under Activities to trigger button colors light intensity or to control the single relay on the back More commands can be added here that are found i...

Страница 16: ...the commands with button presses 1 Buttons 1 This tab allows you to set up macros for each button press 2 Buttons 2 This tab lets you set up secondary commands for Toggle presses 3 Button Settings Thi...

Страница 17: ...Click on the pencil icon in the corner of the button to edit the macro 2 A pop up will appear and show some of the default commands to help guide you 3 Press the Edit pencil next to the command and an...

Страница 18: ...ant button 8 to Mute On when pressed the first time and Mute Off when pressed the second Button Settings Setting Up Repeat or Toggle Under this tab you can set a button to repeat a command like say Vo...

Страница 19: ...set up events to trigger the macros that were built in the previous tabs You can either set a command to repeat or go out a specific time and date You can associate the trigger to either Buttons 1 or...

Страница 20: ...tab you can configure the HIVE KP8 at any time really if needed Network The Hive KP8 has two places to update the network settings either from the HRDF Utility reviewed earlier in the manual or from t...

Страница 21: ...ally or use a backup or use to configure other KP8s in similar rooms Restore Configuration This allows you to upload an XML that was Downloaded from another KP8 or from a backup Reset to Default This...

Страница 22: ...Disable the button locks You can set a timer so it will lock and a code to unlock SETTINGS Time Here you can set the system time and date The unit has an internal battery so this should be retained i...

Страница 23: ...et into the Device Webpage then you can also reset the device from the front panel of the KP8 Remove the decora plate Under the USB port there is a small pin hole Take a paper clip and press while the...

Страница 24: ...lf SN xxx xxx xxx xxx cr lf GW xxx xxx xxx xxx cr lf HTTP PORT 80 cr lf Telnet PORT 23 cr lf Shows the current network IP configuration SETIP N N1 N2 Where N x x x x IP Address N1 x x x x Subnet N2 x...

Страница 25: ...LED brightness control LEDBLUES N where N 0 100 LEDBLUES N CR LF Set the brightness of all blue LEDs LEDREDS N where N 0 100 LEDREDS N CR LF Set the brightness of all red LEDs LEDSHOW N where N ON OF...

Страница 26: ...X X X X IP Address N2 0 65535 Port Number N3 Name Up to 24 characters Add TCP TELNET device in Slot N The name may not contain any spaces DEVICE DELETE N where N 1 16 Device Slot Delete the TCP TELNE...

Страница 27: ...ypad Panel 8 buttons Telnet WebGUI ESD Protection Human body model 12kV air gap discharge 8kV Operating Temp 32 to 122F 0 to 50 20 to 90 non condensing Storing Temp 20 to 60 degC 4 to140 degF Power Su...

Страница 28: ...Hall Technologies 2 1 2024 Page 28 of 28 Copyright 2022 Hall Technologies All rights reserved 1234 Lakeshore Drive Suite 150 Coppell TX 75019 halltechav com support halltechav com 714 641 6607...

Отзывы: