2
2. Local Mode Screen
2-25
L
oca
l M
o
de
Sc
re
en
7-2.
Connection Target Setting
The [Connection Target Setting] tab window on the Communication Setting screen allows you to view
and change the IP address and port number of the connected device.
* The [Connection Target Setting] tab window is displayed only when Ethernet connection is used.
*1 When the connection mode is 1:1, only the connected device is displayed.
When it is 1:n, all devices set in the PLC table in V-SFT version 6 are displayed.
Addition or deletion of a connected device is not possible.
7-3.
Individual Parameter
The [Individual Parameter] tab window on the Connection Setting screen allows you to configure
detailed communication settings.
* [Use Port No. Table] and [Node Address] are not displayed.
[Connection Target Setting] tab window
After changing the setting,
press the [Apply] switch to
confirm the setting.
Changes over the display
between PLC1 to PLC8.
Indicates the maker, model,
and connection port of PLCx.
Pressing each setting field
brings up the system
keyboard to be used for
configuration.
Item
Description
Target
*1
No
Displays the number of the connection target.
Host Name
Displays the station name set in the screen program. (Cannot be changed.)
IP Address
Set the IP address for the connected device.
Port No.
Set the port number of the connected device.
[Individual Parameter] tab window
After changing the setting,
press the [Apply] switch to
confirm the setting.
Item
Description
Transmission Mode
Displayed only when a PLC of Mitsubishi Electric, OMRON, Hitachi Industrial
Equipment System, Yokogawa Electric, JTEKT, or Yaskawa Electric is selected.
For details, refer to the V9 Series Connection Manual.
Read Multiple Blocks at
One Time
Displayed when a PLC of Mitsubishi Electric is selected.
For details, refer to the V9 Series Connection Manual.
Random Read
Содержание Monitouch V9 Series
Страница 1: ...Troubleshooting Maintenance Manual ...
Страница 9: ...11 Before Operation 2 Function Switches 3 System Menu 4 Status Bar MONITOUCH Operations ...
Страница 33: ...1 24 4 Status Bar Please use this page freely ...
Страница 34: ...21 Switching to Local Mode 2 Local Mode Screen 3 Handling Data Changed in Local Mode Local Mode Screen ...
Страница 94: ...2 60 3 Handling Data Changed in Local Mode Please use this page freely ...