ELECTRICAL REQUIREMENTS - CANADA ONLY

WARNING

Electrical Shock Hazard

Electrically ground range.
Failure to do so can result in death, fire or electrical shock.

If codes permit and a separate ground wire is used, it is recommended that a 

qualified electrical installer determine that the ground path is adequate and wire 

gauge are in accordance with local codes.

Be sure that the electrical connection and wire size are adequate and in 

conformance with CSA Standard C22.1, Canadian Electrical Code, Part 1 - latest 

edition, and all local codes and ordinances.

A copy of the above code standards can be obtained from:

Canadian Standards Association 
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA. 

• 

Check with a qualified electrical installer if you are not sure the range is properly 

grounded.

• 

When a 4-wire, single phase 120/240 volt, 60 Hz., AC only electrical supply is 

available, a 50-amp maximum circuit protection is required (or, if specified on 

the model/serial rating plate, when a 4-wire, single phase 120/208 volt 60 Hz., 

AC only electrical supply is available, a 40-amp maximum circuit protection is 

required), fused on both sides of the line.

• 

A time-delay fuse or circuit breaker is recommended.

• 

This range is equipped with a CSA International Certified Power Cord intended 

to be plugged into a standard 14-50R wall receptacle. Be sure the wall receptacle 

is within reach of range’s final location.

• 

Do not use an extension cord.

Содержание HCR2250ADS

Страница 1: ...anding Range Cuisini re autoportante bi combustible de 24 et 36 Estufa independiente para dos combustibles de 24 y 36 Installation Instructions Instructions d installation Instrucciones de instalaci n...

Страница 2: ......

Страница 3: ...GER WARNING CAUTION This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either...

Страница 4: ...ng Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department Installation and service must be perfo...

Страница 5: ...omplete enclosure of the sides and rear of the range To eliminate the risk of burns or fire by reaching over heated surface units cabinet storage space located above the surface units should be avoide...

Страница 6: ...U S A ONLY If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate and wire gauge is in accordance with lo...

Страница 7: ...hrough the neutral use a 4 wire power supply cord rated at 250 volts 40 amps and investigated for use with ranges Electrical Connection To properly install your range you must determine the type of el...

Страница 8: ...om Canadian Standards Association 178 Rexdale Blvd Toronto ON M9W 1R3 CANADA Check with a qualified electrical installer if you are not sure the range is properly grounded When a 4 wire single phase 1...

Страница 9: ...Z223 1 latest edition or CAN CGA B149 latest edition IMPORTANT Leak testing of the range must be conducted according to the manufacturers instructions TYPE OF GAS Natural gas This range is design cer...

Страница 10: ...read is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the range Rigid pipe connection Th...

Страница 11: ...levations above 2 000 ft 609 6 m ratings are reduced at a rate of 4 for each 1 000 ft 304 8 m above sea level not applicable for Canada GAS SUPPLY PRESSURE TESTING Line pressure testing above 0 5 psi...

Страница 12: ...k this location on the floor Attach the anti tip bracket to the floor with 4 screws so that the rear leveling leg will be centered within the bracket once it is in its final position NOTE Contact a qu...

Страница 13: ...h re or electrical shock Be sure your appliance is properly installed and grounded by a qualified technician Ask your dealer to recommend a qualified technician or an authorized repair service This ap...

Страница 14: ...raphic Disconnect the ground from the neutral at free end of conduit Use grounding terminal or lead to ground unit Connect neutral terminal or lead to branch circuit neutral in usual manner Failure to...

Страница 15: ...green GROUND wire from the oven to the GROUND wire in the junction box bare or green colored wire Connect the red and black leads from the oven to the corresponding leads in the junction box Connect...

Страница 16: ...oved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a quali ed person make sure gas pressure does not exceed 14 36 cm water column Examples of a...

Страница 17: ...e or reconnect power CONVERTING TO DIFFERENT TYPES OF GAS When converting from Universal LPG to Natural Gas ensure that the LPG test point is removed and replaced with the CE Approved NG Regulator sup...

Страница 18: ...s pressure conditions it may be necessary to regulate the minimum flame again To set the minimum flame Light the burner Turn the knob to the minimum position Take out the knob and gasket if there is o...

Страница 19: ...rn IN CASE THE APPLIANCE FAILS TO OPERATE CORRECTLY CONTACT THE AUTHORIZED SERVICE PROVIDER IN YOUR AREA Burner and Injector Characteristic Table Burner Position Injector Gas Pressure Rate Diam mm Typ...

Страница 20: ...urs Haier Customer Satisfaction Center au 1 877 337 3639 UNE PREUVE D ACHAT DATEE EST REQUISE POUR BENEFICIER DE LA GARANTIE IMPORTANTE No regrese este producto a la tienda Si tiene alg n problema con...

Отзывы: