GAS PRESSURE REGULATOR

The gas pressure regulator supplied with this range must be used. The inlet pressure 

to the regulator should be as follows for proper operation:

Natural gas:
Minimum pressure: 5” WCP

Maximum pressure: 14” WCP

LP gas:
Minimum pressure: 11” WCP

Maximum pressure: 14” WCP

Contact local gas supplier if you are not sure about the inlet pressure.

Burner Input Requirements
Input ratings shown on the model/serial rating plate are for elevations up to 2,000 ft 

(609.6 m).

For elevations above 2,000 ft (609.6 m), ratings are reduced at a rate of 4% for each 

1,000 ft (304.8 m) above sea level (not applicable for Canada).

GAS SUPPLY PRESSURE TESTING

Line pressure testing above 0.5 psi gauge (14” WCP) 
The range and its individual shutoff valve must be disconnected from the gas supply 

piping system during any pressure testing of that system at test pressures in excess 

of 0.5 psi (3.5 kPa).

Line pressure testing at 0.5 psi gauge (14” WCP) or lower 
The range must be isolated from the gas supply piping system by closing its 

individual manual shutoff valve during any pressure testing of the gas supply piping 

system at test pressures equal to or less than 0.5 psi (3.5 kPa).

Содержание HCR2250ADS

Страница 1: ...anding Range Cuisini re autoportante bi combustible de 24 et 36 Estufa independiente para dos combustibles de 24 y 36 Installation Instructions Instructions d installation Instrucciones de instalaci n...

Страница 2: ......

Страница 3: ...GER WARNING CAUTION This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either...

Страница 4: ...ng Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department Installation and service must be perfo...

Страница 5: ...omplete enclosure of the sides and rear of the range To eliminate the risk of burns or fire by reaching over heated surface units cabinet storage space located above the surface units should be avoide...

Страница 6: ...U S A ONLY If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate and wire gauge is in accordance with lo...

Страница 7: ...hrough the neutral use a 4 wire power supply cord rated at 250 volts 40 amps and investigated for use with ranges Electrical Connection To properly install your range you must determine the type of el...

Страница 8: ...om Canadian Standards Association 178 Rexdale Blvd Toronto ON M9W 1R3 CANADA Check with a qualified electrical installer if you are not sure the range is properly grounded When a 4 wire single phase 1...

Страница 9: ...Z223 1 latest edition or CAN CGA B149 latest edition IMPORTANT Leak testing of the range must be conducted according to the manufacturers instructions TYPE OF GAS Natural gas This range is design cer...

Страница 10: ...read is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the range Rigid pipe connection Th...

Страница 11: ...levations above 2 000 ft 609 6 m ratings are reduced at a rate of 4 for each 1 000 ft 304 8 m above sea level not applicable for Canada GAS SUPPLY PRESSURE TESTING Line pressure testing above 0 5 psi...

Страница 12: ...k this location on the floor Attach the anti tip bracket to the floor with 4 screws so that the rear leveling leg will be centered within the bracket once it is in its final position NOTE Contact a qu...

Страница 13: ...h re or electrical shock Be sure your appliance is properly installed and grounded by a qualified technician Ask your dealer to recommend a qualified technician or an authorized repair service This ap...

Страница 14: ...raphic Disconnect the ground from the neutral at free end of conduit Use grounding terminal or lead to ground unit Connect neutral terminal or lead to branch circuit neutral in usual manner Failure to...

Страница 15: ...green GROUND wire from the oven to the GROUND wire in the junction box bare or green colored wire Connect the red and black leads from the oven to the corresponding leads in the junction box Connect...

Страница 16: ...oved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a quali ed person make sure gas pressure does not exceed 14 36 cm water column Examples of a...

Страница 17: ...e or reconnect power CONVERTING TO DIFFERENT TYPES OF GAS When converting from Universal LPG to Natural Gas ensure that the LPG test point is removed and replaced with the CE Approved NG Regulator sup...

Страница 18: ...s pressure conditions it may be necessary to regulate the minimum flame again To set the minimum flame Light the burner Turn the knob to the minimum position Take out the knob and gasket if there is o...

Страница 19: ...rn IN CASE THE APPLIANCE FAILS TO OPERATE CORRECTLY CONTACT THE AUTHORIZED SERVICE PROVIDER IN YOUR AREA Burner and Injector Characteristic Table Burner Position Injector Gas Pressure Rate Diam mm Typ...

Страница 20: ...urs Haier Customer Satisfaction Center au 1 877 337 3639 UNE PREUVE D ACHAT DATEE EST REQUISE POUR BENEFICIER DE LA GARANTIE IMPORTANTE No regrese este producto a la tienda Si tiene alg n problema con...

Отзывы: