10

INSTALL RANGE

INSTALL ANTI-TIP BRACKET

IMPORTANT:

• 

An Anti-Tip Bracket kit is included with the range. Follow the instructions 

supplied with the anti-tip bracket. 

• 

Do not completely remove the rear leveling leg. The anti-tip bracket uses the 

rear leveling leg to secure the range to the floor.

• 

The anti-tip bracket should be installed, so that it secures either the right or left 

rear leveling leg. 

• 

After installing the leveling leg, note the distance from the side of the range to 

the center of the leveling leg. Mark this location on the floor. 

• 

Attach the anti-tip bracket to the floor with 4 screws so that the rear leveling leg 

will be  centered within the bracket once it is in its final position. 

NOTE: Contact a qualified floor covering installer for the best procedure for drilling 

mounting holes through your type of floor covering.  

ELECTRICAL CONNECTION

POWER SUPPLY CORD

WARNING

Electrical Shock Hazard

Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to do so can result in death, fire or electrical shock.

1.  Disconnect power.
2.  Remove the terminal block cover screws located on the back of the range. Pull 

cover down and toward you to remove cover.

3.  Add strain relief.

Содержание HCR2250ADS

Страница 1: ...anding Range Cuisini re autoportante bi combustible de 24 et 36 Estufa independiente para dos combustibles de 24 y 36 Installation Instructions Instructions d installation Instrucciones de instalaci n...

Страница 2: ......

Страница 3: ...GER WARNING CAUTION This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either...

Страница 4: ...ng Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department Installation and service must be perfo...

Страница 5: ...omplete enclosure of the sides and rear of the range To eliminate the risk of burns or fire by reaching over heated surface units cabinet storage space located above the surface units should be avoide...

Страница 6: ...U S A ONLY If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate and wire gauge is in accordance with lo...

Страница 7: ...hrough the neutral use a 4 wire power supply cord rated at 250 volts 40 amps and investigated for use with ranges Electrical Connection To properly install your range you must determine the type of el...

Страница 8: ...om Canadian Standards Association 178 Rexdale Blvd Toronto ON M9W 1R3 CANADA Check with a qualified electrical installer if you are not sure the range is properly grounded When a 4 wire single phase 1...

Страница 9: ...Z223 1 latest edition or CAN CGA B149 latest edition IMPORTANT Leak testing of the range must be conducted according to the manufacturers instructions TYPE OF GAS Natural gas This range is design cer...

Страница 10: ...read is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the range Rigid pipe connection Th...

Страница 11: ...levations above 2 000 ft 609 6 m ratings are reduced at a rate of 4 for each 1 000 ft 304 8 m above sea level not applicable for Canada GAS SUPPLY PRESSURE TESTING Line pressure testing above 0 5 psi...

Страница 12: ...k this location on the floor Attach the anti tip bracket to the floor with 4 screws so that the rear leveling leg will be centered within the bracket once it is in its final position NOTE Contact a qu...

Страница 13: ...h re or electrical shock Be sure your appliance is properly installed and grounded by a qualified technician Ask your dealer to recommend a qualified technician or an authorized repair service This ap...

Страница 14: ...raphic Disconnect the ground from the neutral at free end of conduit Use grounding terminal or lead to ground unit Connect neutral terminal or lead to branch circuit neutral in usual manner Failure to...

Страница 15: ...green GROUND wire from the oven to the GROUND wire in the junction box bare or green colored wire Connect the red and black leads from the oven to the corresponding leads in the junction box Connect...

Страница 16: ...oved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a quali ed person make sure gas pressure does not exceed 14 36 cm water column Examples of a...

Страница 17: ...e or reconnect power CONVERTING TO DIFFERENT TYPES OF GAS When converting from Universal LPG to Natural Gas ensure that the LPG test point is removed and replaced with the CE Approved NG Regulator sup...

Страница 18: ...s pressure conditions it may be necessary to regulate the minimum flame again To set the minimum flame Light the burner Turn the knob to the minimum position Take out the knob and gasket if there is o...

Страница 19: ...rn IN CASE THE APPLIANCE FAILS TO OPERATE CORRECTLY CONTACT THE AUTHORIZED SERVICE PROVIDER IN YOUR AREA Burner and Injector Characteristic Table Burner Position Injector Gas Pressure Rate Diam mm Typ...

Страница 20: ...urs Haier Customer Satisfaction Center au 1 877 337 3639 UNE PREUVE D ACHAT DATEE EST REQUISE POUR BENEFICIER DE LA GARANTIE IMPORTANTE No regrese este producto a la tienda Si tiene alg n problema con...

Отзывы: