15
TYPICAL FLEXIBLE CONNECTION
1. Apply pipe-joint compound made for use with LP gas to the smaller thread ends
of the flexible connector adapters.
2. Attach one adapter to the gas pressure regulator and the other adapter to the
gas shutoff valve. Tighten both adapters.
3. Use a 15/16” combination wrench and channel lock pliers to attach the flexible
connector to the adapters. Check that connector is not kinked.
COMPLETE CONNECTION
1. Open the manual shutoff valve in the gas supply line. The valve is open when the
handle is parallel to the gas pipe.
2. Test all connections by brushing on an approved noncorrosive leak-detection
solution. If bubbles appear, a leak is indicated. Correct any leak found.
3. Plug in range or reconnect power.
CONVERTING TO DIFFERENT TYPES OF GAS
When converting from Universal LPG to Natural Gas ensure that the LPG test point
is removed and replaced with the CE Approved NG Regulator supplied in this kit. The
test point pressure must be adjusted to 4”W.C with the largest burner operating on
maximum flame.
When converting from Natural Gas to Universal LPG ensure that the NG regulator
is removed and replaced with the Test Point Assembly supplied in this kit. An CE
Approved gas regulator suitable for a supply pressure of 10”W.C should be part of
the gas tank supply and the test point pressure must be adjusted to 10”W.C.
To adapt the range to a gas different from that for which it was set up (see gas type
label inside the warming compartment door) proceed as follows:
1. Remove the grids
2. Remove the burners caps and burner heads
3. Using a 7 mm socket spanner unscrew and remove the injectors.