17
ABNORMAL OPERATION
ANY OF THE FOLLOWING ARE CONSIDERED TO BE ABNORMAL OPERATION
AND MAY REQUIRE SERVICING:
•
Yellow tipping of the hob burner flame.
•
Sooting up of cooking utensils.
•
Burners not igniting properly.
•
Burners failing to remain lit.
•
Burners extinguished by oven door.
•
Gas valves, which are difficult to turn.
IN CASE THE APPLIANCE FAILS TO OPERATE CORRECTLY, CONTACT THE
AUTHORIZED SERVICE PROVIDER IN YOUR AREA
Burner and Injector Characteristic Table
Burner
Position
Injector
Gas
Pressure Rate
Diam. (mm) Type
[i.w.c.]
[BTU/h]
Auxiliary
Front R
1.1
NG
4”
4967
0.7
LP (Propane)
10”
4879
Semi-Rapid
Rear L and R
1.29
NG
4”
7055
0.8
LP (Propane)
10”
6472
Dual Burner
Center Inner
0.99*5
NG
4”
17882
Center Outer
0.56*6
LP (Propane)
10”
15586
2
2
3
1
2
2
4
3
a
a
a
Opening in grate for wok ring (provided) is located over left front burner.